Inter-Rater and Intra-Rater Repeatability and Reliability of EOS 3-Dimensional Imaging Analysis Software

被引:17
作者
Demzik, Alysen L. [1 ]
Alvi, Hasham M. [2 ]
Delagrammaticas, Dimitri E. [2 ]
Martell, John M. [3 ]
Beal, Matthew D. [2 ]
Manning, David W. [2 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Orthopaed Surg, 676 N St Clair,Suite 1350, Chicago, IL 60611 USA
[3] Univ Chicago, Dept Orthopaed Surg, Chicago, IL 60637 USA
关键词
total hip arthroplasty; radiographic analysis; EOS imaging; TOTAL HIP-ARTHROPLASTY; TRANSVERSE ACETABULAR LIGAMENT; POLYETHYLENE WEAR; COMPONENT ORIENTATION; SPINE; CUP; REPLACEMENT; PELVIS; RECONSTRUCTION; RADIOGRAPHS;
D O I
10.1016/j.arth.2015.11.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Quantifying ideal component position for the acetabulum and stem during total hip arthroplasty (THA) has been described by many methods. A new imaging method using low-dose digital stereoradiography, the EOS imaging system, is a biplanar low-dose X-ray system that allows for 3-dimensional modeling of lower limbs and semiautomated measurement of pelvic parameters and implant alignment. Methods: Twenty-five patients who underwent primary THA by a single surgeon between October 2014 and December 2014 were retrospectively selected. Only patients with unilateral THA without associated spine pathologies were included, totaling 16 right hips and 9 left hips. There were 8 men and 17 women in the cohort, with a mean age of 67 years (range, 53-82). Three individuals performed measurements of pelvic parameters and implant alignment on 3 separate occasions. An interclass correlation of >0.75 was accepted as evidence of excellent agreement and a confirmation of measurement reliability. Results: Before reviewing patient radiographs, 4 pelvic phantom models were analyzed using the EOS 3-dimensional software to verify accuracy. All anatomic and implant measurements performed by the 3 independent reviewers showed interobserver and intraobserver agreement with interclass correlation >0.75. Conclusion: Three-dimensional modeling of hip implants with the EOS imaging system is a reasonable option for the evaluation of component position after THA. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1091 / 1095
页数:5
相关论文
共 32 条
[1]   The Combined Anteversion Technique for Acetabular Component Anteversion [J].
Amuwa, Christopher ;
Dorr, Lawrence D. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :1068-1070
[2]  
Archbold HAP, 2008, HIP INT, V18, P1
[3]   The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement - A preliminary study of 1000 cases investigating postoperative stability [J].
Archbold, H. A. P. ;
Mockford, B. ;
Molloy, D. ;
McConway, J. ;
Ogonda, L. ;
Beverland, D. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07) :883-886
[4]   The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: Prospective study with the EOS imaging system [J].
Barbier, O. ;
Skalli, W. ;
Mainard, L. ;
Mainard, D. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (06) :S287-S291
[5]  
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[6]   Pelvic tilt measurement before and after total hip arthroplasty [J].
Blondel, B. ;
Parratte, S. ;
Tropiano, P. ;
Pauly, V. ;
Aubaniac, J. -M. ;
Argenson, J. -N. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (08) :568-572
[7]   Validation of new clinical quantitative analysis software applicable in spine orthopaedic studies [J].
Champain, S. ;
Benchikh, K. ;
Nogier, A. ;
Mazel, C. ;
Guise, J. De. ;
Skalli, W. .
EUROPEAN SPINE JOURNAL, 2006, 15 (06) :982-991
[8]   Intra- and inter-observer reliability of determining radiographic sagittal parameters of the spine and pelvis using a manual and a computer-assisted methods [J].
Dimar, John R., II ;
Carreon, Leah Y. ;
Labelle, Hubert ;
Djurasovic, Mladen ;
Weidenbaum, Mark ;
Brown, Courtney ;
Roussouly, Pierre .
EUROPEAN SPINE JOURNAL, 2008, 17 (10) :1373-1379
[9]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[10]   Natural acetabular orientation in arthritic hips [J].
Goudie, S. T. ;
Deakin, A. H. ;
Deep, K. .
BONE & JOINT RESEARCH, 2015, 4 (01) :6-10