Inter-Rater and Intra-Rater Repeatability and Reliability of EOS 3-Dimensional Imaging Analysis Software

被引:17
作者
Demzik, Alysen L. [1 ]
Alvi, Hasham M. [2 ]
Delagrammaticas, Dimitri E. [2 ]
Martell, John M. [3 ]
Beal, Matthew D. [2 ]
Manning, David W. [2 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Orthopaed Surg, 676 N St Clair,Suite 1350, Chicago, IL 60611 USA
[3] Univ Chicago, Dept Orthopaed Surg, Chicago, IL 60637 USA
关键词
total hip arthroplasty; radiographic analysis; EOS imaging; TOTAL HIP-ARTHROPLASTY; TRANSVERSE ACETABULAR LIGAMENT; POLYETHYLENE WEAR; COMPONENT ORIENTATION; SPINE; CUP; REPLACEMENT; PELVIS; RECONSTRUCTION; RADIOGRAPHS;
D O I
10.1016/j.arth.2015.11.026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Quantifying ideal component position for the acetabulum and stem during total hip arthroplasty (THA) has been described by many methods. A new imaging method using low-dose digital stereoradiography, the EOS imaging system, is a biplanar low-dose X-ray system that allows for 3-dimensional modeling of lower limbs and semiautomated measurement of pelvic parameters and implant alignment. Methods: Twenty-five patients who underwent primary THA by a single surgeon between October 2014 and December 2014 were retrospectively selected. Only patients with unilateral THA without associated spine pathologies were included, totaling 16 right hips and 9 left hips. There were 8 men and 17 women in the cohort, with a mean age of 67 years (range, 53-82). Three individuals performed measurements of pelvic parameters and implant alignment on 3 separate occasions. An interclass correlation of >0.75 was accepted as evidence of excellent agreement and a confirmation of measurement reliability. Results: Before reviewing patient radiographs, 4 pelvic phantom models were analyzed using the EOS 3-dimensional software to verify accuracy. All anatomic and implant measurements performed by the 3 independent reviewers showed interobserver and intraobserver agreement with interclass correlation >0.75. Conclusion: Three-dimensional modeling of hip implants with the EOS imaging system is a reasonable option for the evaluation of component position after THA. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1091 / 1095
页数:5
相关论文
共 32 条
  • [1] The Combined Anteversion Technique for Acetabular Component Anteversion
    Amuwa, Christopher
    Dorr, Lawrence D.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07) : 1068 - 1070
  • [2] Archbold HAP, 2008, HIP INT, V18, P1
  • [3] The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement - A preliminary study of 1000 cases investigating postoperative stability
    Archbold, H. A. P.
    Mockford, B.
    Molloy, D.
    McConway, J.
    Ogonda, L.
    Beverland, D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07): : 883 - 886
  • [4] The reliability of the anterior pelvic plane for computer navigated acetabular component placement during total hip arthroplasty: Prospective study with the EOS imaging system
    Barbier, O.
    Skalli, W.
    Mainard, L.
    Mainard, D.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (06) : S287 - S291
  • [5] Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
  • [6] Pelvic tilt measurement before and after total hip arthroplasty
    Blondel, B.
    Parratte, S.
    Tropiano, P.
    Pauly, V.
    Aubaniac, J. -M.
    Argenson, J. -N.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (08) : 568 - 572
  • [7] Validation of new clinical quantitative analysis software applicable in spine orthopaedic studies
    Champain, S.
    Benchikh, K.
    Nogier, A.
    Mazel, C.
    Guise, J. De.
    Skalli, W.
    [J]. EUROPEAN SPINE JOURNAL, 2006, 15 (06) : 982 - 991
  • [8] Intra- and inter-observer reliability of determining radiographic sagittal parameters of the spine and pelvis using a manual and a computer-assisted methods
    Dimar, John R., II
    Carreon, Leah Y.
    Labelle, Hubert
    Djurasovic, Mladen
    Weidenbaum, Mark
    Brown, Courtney
    Roussouly, Pierre
    [J]. EUROPEAN SPINE JOURNAL, 2008, 17 (10) : 1373 - 1379
  • [9] Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
  • [10] Natural acetabular orientation in arthritic hips
    Goudie, S. T.
    Deakin, A. H.
    Deep, K.
    [J]. BONE & JOINT RESEARCH, 2015, 4 (01): : 6 - 10