Electromagnetic Transient Simulation of Large Power Transformer Internal Fault

被引:0
作者
Liu, Jun [1 ]
Xiao, Shiwu [1 ]
Sun, Qingsen [2 ]
Wang, Huaxing [2 ]
Yang, Lei [2 ]
机构
[1] North China Elect Power Univ, Sch Elect & Elect Engn, Beijing, Peoples R China
[2] State Grid Shandong Elect Power Co, Taian Power Supply Co, Tai An, Shandong, Peoples R China
来源
PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY AND ENVIRONMENTAL SCIENCE 2015 | 2015年 / 31卷
关键词
parameters of transformer; internal fault; simulation; mathematical model;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, in the neglect of the core of the magnetic hysteresis, eddy current effect and the core skin effect and based on the analysis and summary of previous experience, an analytical method to determine the parameters of the transformer's turn to turn short circuit fault is improved and perfected in order to determine the parameters of the transformer when the turn-to-turn fault and turn-to-ground fault happens at any position of the transformer. Through the mathematical model of transformer after fault, we can obtain the node voltage equation of the simulation network. And then we adopt three principles to calculate the unknown parameters in the node voltage equation we obtained before. Simulation results verify the effectiveness of the proposed algorithm.
引用
收藏
页码:706 / 711
页数:6
相关论文
共 6 条
[1]  
Huang Yong-rong, 2007, Relay, V35, P26
[2]  
Qi Richang, 2006, POWER TRANSFORMER
[3]  
Wang Xue, 2004, Power System Technology, V28, P50
[4]  
Zhang B.H., 2010, POWER SYSTERM PROTEC
[5]  
Zhao Ze-Yi, 2001, Journal of Tongji University (Natural Science), V29, P416
[6]  
[朱翊 Zhu Yi], 2012, [电网技术, Power System Technology], V36, P116