共 7 条
Preliminary ossiculoplasty results using the Kurz titanium prostheses
被引:50
作者:
Krueger, WWO
Feghali, JG
Shelton, C
Green, JD
Beatty, CW
Wilson, DF
Thedinger, BS
Barrs, DM
McElveen, JT
机构:
[1] Otol Grp, San Antonio, TX 78240 USA
[2] Albert Einstein Coll Med, New York, NY USA
[3] Univ Utah, Salt Lake City, UT USA
[4] Jacksonville Hearing & Balance Inst, Jacksonville, FL USA
[5] Mayo Clin, Rochester, MN USA
[6] Wilson Ear Clin, Portland, OR USA
[7] Otol Ctr Inc, Kansas City, MO USA
[8] Carolina Ear & Hearing Inst, Raleigh, NC USA
关键词:
ossiculoplasty;
hearing reconstruction;
Kurz titanium prostheses;
D O I:
10.1097/00129492-200211000-00004
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
Objective: Limitations in biocompatibility and hearing improvement with ossicular chain reconstruction prostheses are addressed with new, lightweight titanium prostheses designed to maximize visualization of the capitulum and footplate regions. The effectiveness of these new prostheses is being tested in a prospective multicenter study. Study Design: Prospective case series. Setting: Multicenter (8 sites), primarily tertiary private practice or academic otologic clinics. Patients: A convenience sample of 31 patients undergoing ossiculoplasty, with 16 partial ossicular chain reconstructions using the Bell prosthesis and 15 total reconstructions using the Aerial prosthesis. Intervention: Ossiculoplasty using new Kurz titanium prostheses. Cartilage was interposed between the tympanic membrane and the prosthesis. Main Outcome Measures: Air-bone gap for pure tone average and 3,000 and 4,000 Hz, assessed preoperatively and 3 months, 6 months, and 12 months postoperatively; percent of patients obtaining an air-bone gap of less than or equal to 20 dB; high-frequency average (1,000, 2,000, and 4,000 Hz) to evaluate sensorineural hearing loss; and extrusion rate. Results: A postoperative air-bone gap of less than or equal to 20 dB was obtained in 81% of Bell prosthesis patients and 67% of Aerial prosthesis patients at 3 months. The results were stable to improved for later time intervals. High-frequency gaps were similar to the pure tone average gap. To date, there have been no instances of extrusion, and all the surgeons found the prostheses easy to use and thought that the design characteristics facilitated accurate placement. Conclusions: Initial evaluation of the Kurz titanium prostheses produced low extrusion rates (none to date) with excellent hearing results, including good high-frequency conduction. Good visualization and accurate placement were easy to achieve. Further studies are needed to confirm long-term efficacy.
引用
收藏
页码:836 / 839
页数:4
相关论文