Partial Discharges Pulse Shape Analysis at AC and DC

被引:0
作者
Pihera, Josef [1 ]
Hornak, Jaroslav [1 ]
Vobornik, Ales [1 ]
Kupka, Lukas [1 ]
Chladek, Svatoslav [1 ]
Haller, Rainer [1 ]
机构
[1] Univ West Bohemia, Fac Elect Engn, Reg Innovat Ctr Elect Engn, Plzen, Czech Republic
来源
PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1 | 2020年 / 598卷
关键词
Partial discharges; Pulse shape; Measuring impedance; Statistical analysis;
D O I
10.1007/978-3-030-31676-1_52
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) signal analysis is a well-known tool for monitoring the conditions of insulation systems of electrical machines and equipment. Classical analyzes of PD are mostly based on the evaluation of the phase angle of the test voltage at which partial discharges occur. At the present, the partial discharge detection is mostly based on the measurement of charging currents that are needed to resume the voltage on the sample that was there before the partial discharge occurred. Other electrical methods are, for example, the scanning of an electromagnetic field emitted during a partial discharge. Another developed methodology in the field of measuring and analyzing partial discharges is the monitoring of pulse parameters of the detected discharge. Experiments suggest that measuring the rise and fall time of the pulse edges and amplitude measurements can evaluate the partial discharge signal. Especially this method could be very helpful at the moment when partial discharges at DC are studied and evaluated. The disadvantage of partial discharges at DC is the fact there is no phase and phase angle position for PD patterns recognition. Thus, another evaluation method development is necessary for PD recognition DC. There is presented in the study an experiment where the PD pulse shapes, in the manner of rise time and fall time, were investigated at laboratory PD models at both voltage types AC and DC. The PD models simulated corona discharges. Each individual pulse of a partial discharge can be detected by a suitable scanning impedance and viewed with fast digital oscilloscopes. As has been said, there is a presumption that different discharge arrangements or even variously degraded insulating materials have different waveforms of the sensed pulses. The main monitored parameters of individual pulses are their rise time and amplitude. Since the occurrence of partial discharge is essentially a random phenomenon, statistical analysis of a significant amount of data is required. A view of the behaviour of the partial discharge pulse in various cases of the discharge activity brings different results in the observation of the pulse rise time and its amplitude in the various observed setups. Monitoring the rise time and pulse amplitude is one way of evaluating partial discharges, regardless of their superimposed position on the sine wave of the supply voltage. Thus this PD monitoring could be a part of PD evaluation at DC. These pulse parameters together with other PD analysis at DC (as pulse sequence analysis) could be used to estimate the partial discharge type as well as to evaluate the deterioration of the insulation of electrical machines.
引用
收藏
页码:549 / 559
页数:11
相关论文
共 50 条
  • [41] Stochastic Detection of Partial Discharges
    Bengtsson, Tord
    Lindell, Elisabeth
    Hammarstrom, Thomas
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2203 - 2211
  • [42] PARTIAL DISCHARGES IN DIELECTRIC LIQUIDS
    Do, M. T.
    Auge, J. -L.
    Vu, T. A. T.
    Catallani, S.
    [J]. ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 75 - 75
  • [43] Partial Discharges: Questions for Discussion
    Ovsyannikov, Alexander
    Zhivodernikov, Sergey
    Vodennikov, Dmitry
    Kokh, Alexander
    [J]. 2020 INTERNATIONAL CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING, DIAGNOSTIKA, 2020, : 28 - 33
  • [44] Study of partial discharges in liquids
    Korobeynikov, S. M.
    Ovsyannikov, A. G.
    Ridel, A., V
    Karpov, D., I
    Lyutikova, M. N.
    Kuznetsova, Yu A.
    Yassinskiy, V. B.
    [J]. JOURNAL OF ELECTROSTATICS, 2020, 103
  • [45] Behavior of Partial Discharges in Mineral Oil with Solid Dielectric Barrier under Long-Term AC Voltage
    Kunicki, Michal
    [J]. 2018 IEEE 2ND INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), 2018,
  • [46] The time-frequency analysis of multi-source partial discharges
    Boczar, Tomasz
    Borucki, Sebastian
    Cichon, Andrzej
    Lorenc, Marcin
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (12): : 339 - 341
  • [47] Behavior of Partial Discharges in Mineral Oil with Solid Dielectric Barrier under Long-Term AC Voltage
    Kunicki, Michal
    [J]. 2018 IEEE 2ND INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), 2018,
  • [48] Analysis and comparison of sensors for measurements of partial discharges in hydrogenerator stator windings
    Dmitriev, Victor
    De Oliveira, Rodrigo M.S.
    Brasil, Fernando S.
    De Vilhena, Paulo R.M.
    Modesto, Jonathas F.M.
    Zampolo, Ronaldo F.
    [J]. Journal of Microwaves, Optoelectronics and Electromagnetic Applications, 2015, 14 (02): : 197 - 216
  • [49] Analysis of Partial Discharges and Failure Mechanism in Electrical Machines with Hairpin Winding
    Hanisch, Lucas Vincent
    Dietrich, Tim-Hendrik
    Henke, Markus
    [J]. 2021 IEEE 13TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2021, : 37 - 43
  • [50] A method for the behavioral analysis of partial discharges in hydrogenerators by generalized linear models
    Gomes, F. J. S.
    Oliveira, T. F.
    Brazil, F. S.
    Pamplona, A. R., Jr.
    Farias, V. J.
    Silveira, A. M.