Partial Discharges Pulse Shape Analysis at AC and DC

被引:0
|
作者
Pihera, Josef [1 ]
Hornak, Jaroslav [1 ]
Vobornik, Ales [1 ]
Kupka, Lukas [1 ]
Chladek, Svatoslav [1 ]
Haller, Rainer [1 ]
机构
[1] Univ West Bohemia, Fac Elect Engn, Reg Innovat Ctr Elect Engn, Plzen, Czech Republic
来源
PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1 | 2020年 / 598卷
关键词
Partial discharges; Pulse shape; Measuring impedance; Statistical analysis;
D O I
10.1007/978-3-030-31676-1_52
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) signal analysis is a well-known tool for monitoring the conditions of insulation systems of electrical machines and equipment. Classical analyzes of PD are mostly based on the evaluation of the phase angle of the test voltage at which partial discharges occur. At the present, the partial discharge detection is mostly based on the measurement of charging currents that are needed to resume the voltage on the sample that was there before the partial discharge occurred. Other electrical methods are, for example, the scanning of an electromagnetic field emitted during a partial discharge. Another developed methodology in the field of measuring and analyzing partial discharges is the monitoring of pulse parameters of the detected discharge. Experiments suggest that measuring the rise and fall time of the pulse edges and amplitude measurements can evaluate the partial discharge signal. Especially this method could be very helpful at the moment when partial discharges at DC are studied and evaluated. The disadvantage of partial discharges at DC is the fact there is no phase and phase angle position for PD patterns recognition. Thus, another evaluation method development is necessary for PD recognition DC. There is presented in the study an experiment where the PD pulse shapes, in the manner of rise time and fall time, were investigated at laboratory PD models at both voltage types AC and DC. The PD models simulated corona discharges. Each individual pulse of a partial discharge can be detected by a suitable scanning impedance and viewed with fast digital oscilloscopes. As has been said, there is a presumption that different discharge arrangements or even variously degraded insulating materials have different waveforms of the sensed pulses. The main monitored parameters of individual pulses are their rise time and amplitude. Since the occurrence of partial discharge is essentially a random phenomenon, statistical analysis of a significant amount of data is required. A view of the behaviour of the partial discharge pulse in various cases of the discharge activity brings different results in the observation of the pulse rise time and its amplitude in the various observed setups. Monitoring the rise time and pulse amplitude is one way of evaluating partial discharges, regardless of their superimposed position on the sine wave of the supply voltage. Thus this PD monitoring could be a part of PD evaluation at DC. These pulse parameters together with other PD analysis at DC (as pulse sequence analysis) could be used to estimate the partial discharge type as well as to evaluate the deterioration of the insulation of electrical machines.
引用
收藏
页码:549 / 559
页数:11
相关论文
共 50 条
  • [21] Investigation on the pulse shape of DC corona discharges in air under varying test voltage level
    Luehring, Ulrich
    Wienold, Daniel
    Jenau, Frank
    2018 IEEE 2ND INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), 2018,
  • [22] The current and voltage time variations simulation of tbe relaxation pulse discharges, generated by dc and ac sources
    Mustata, I
    Biloiu, C
    Leu, GF
    Popescu, A
    Musa, G
    INTERNATIONAL CONFERENCE ON PHENOMENA IN IONIZED GASES, VOL IV, PROCEEDINGS, 1999, : 219 - 220
  • [23] Pulse-sequence analysis of partial discharges in a void and electrical treeing
    Suwarno
    Suzuoki, Y
    Mizutani, T
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 130 - 133
  • [24] Phase behavior in AC generated partial discharges: electroconvection and the moderation of discharges
    Stricklett, KL
    vonGlahn, P
    VanBrunt, RJ
    IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 525 - 525
  • [25] Phase Resolved Analysis of Partial Discharges in Liquid Nitrogen Under AC Voltages
    Truong, L. H.
    Lewin, P. L.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2179 - 2187
  • [26] PARTIAL DISCHARGES IN GASEOUS VOIDS FOR DC VOLTAGE
    KREUGER, FH
    FROMM, U
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1994, 33 (02): : 1079 - 1084
  • [27] Partial discharges in gaseous voids for DC voltage
    Kreuger, Frederik H., 1600, Publ by JJAP, Minato-ku (33):
  • [28] About the kinetic power induced by AC and DC discharges
    Moreau, E
    Touchard, G
    2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, : 469 - 473
  • [29] MONOCHROMATISATION EFFECT - AC/DC DISCHARGES COMPARATIVE BEHAVIOR
    Ciobotaru, L. C.
    ROMANIAN REPORTS IN PHYSICS, 2010, 62 (01) : 134 - 141
  • [30] Partial discharge characteristics in polyethylene using Pulse Shape and Pulse Sequence Analysis
    Arief, Y. Z.
    Patsch, R.
    Benzerouk, D.
    Menzel, J.
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 308 - +