Computer assisted detection software for CT colonography: effect of sphericity filter on performance characteristics for patients with and without fecal tagging
被引:14
作者:
Dehmeshki, Jamshid
论文数: 0引用数: 0
h-index: 0
机构:UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
Dehmeshki, Jamshid
Halligan, Steve
论文数: 0引用数: 0
h-index: 0
机构:UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
Halligan, Steve
Taylor, Stuart A.
论文数: 0引用数: 0
h-index: 0
机构:UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
Taylor, Stuart A.
Roddie, Mary E.
论文数: 0引用数: 0
h-index: 0
机构:UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
Roddie, Mary E.
McQuillan, Justine
论文数: 0引用数: 0
h-index: 0
机构:UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
McQuillan, Justine
Honeyfield, Lesley
论文数: 0引用数: 0
h-index: 0
机构:UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
Honeyfield, Lesley
Amin, Hamdan
论文数: 0引用数: 0
h-index: 0
机构:UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
Amin, Hamdan
机构:
[1] UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England
The aim of this study is to investigate the effect of changing sphericity filter values on performance of a computer assisted detection (CAD) system for CT colonography for data with and without fecal tagging. Colonography data from 138 patients with 317 validated polyps were divided into those with (86) and without (52) fecal tagging. Polyp coordinates were established by three observers and datasets analysed subsequently by a proprietary CAD system used at four discrete sphericity filter settings. Prompts were compared with the known coordinates in order to determine sensitivity and specificity. Sensitivity was highest at low sphericity; of 164 polyps 6 mm or more, 144 (87.8%) were detected at sphericity 0.3, and 132 (80.1%) at sphericity 0.9. Of 42 polyps measuring 10 mm or more, 40 (95.2%) were detected at sphericity 0.3, and 36 (85.7%) at sphericity 0.9. There was no significant difference in sensitivity for tagged and un-tagged data but specificity was reduced in tagged data at low sphericity and significantly reduced in untagged data at high sphericity. CAD had a sensitivity of 95.2% for polyps measuring 1 cm or more and 87.8% for polyps 6 mm or more when used at a sphericity setting of 0.3. Higher sphericity settings increased specificity while reducing sensitivity. The bowel preparation used significantly impacts on specificity.