A tantalum electrode coated with graphene nanowalls for simultaneous voltammetric determination of dopamine, uric acid, L-tyrosine, and hydrochlorothiazide

被引:39
作者
Tian, Fangyuan [1 ]
Li, Hongji [1 ]
Li, Mingji [2 ]
Li, Cuiping [2 ]
Lei, Yingjie [1 ]
Yang, Baohe [2 ]
机构
[1] Tianjin Univ Technol, Sch Chem & Chem Engn, Tianjin Key Lab Organ Solar Cells & Photochem Con, Tianjin 300384, Peoples R China
[2] Tianjin Univ Technol, Sch Elect Informat Engn, Tianjin Key Lab Film Elect & Communicate Devices, Tianjin 300384, Peoples R China
基金
中国国家自然科学基金;
关键词
Multiple sensing; Scanning electronmicroscopy; Transmission electron microscopy; X-ray diffraction; Differential pulse voltammetry; Electrochemical impedance spectroscopy; Electro catalysis; GLASSY-CARBON ELECTRODE; DOPED DIAMOND ELECTRODE; ASCORBIC-ACID; NANOTUBES; OXIDE; AMLODIPINE; VALSARTAN; DISEASE; COMPLEX;
D O I
10.1007/s00604-017-2154-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe a voltammetric sensor for simultaneous determination of dopamine (DA), uric acid (UA), L-tyrosine (Tyr), and the diuretic drug hydrochlorothiazide (HCTZ). The assay is based on the use of graphene nanowalls deposited on a tantalum substrate. The nanowalls are characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, electrochemical impedance spectroscopy, and cyclic voltammetry. The nanowalls are vertically grown on the substrate by direct-current arc plasma jet chemical vapor deposition. The modified electrode is shown to enable simultaneous differential pulse voltammetric determination of DA, UA, Tyr, and HCTZ. The graphene nanowalls display a large specific surface, high conductivity, and a large number of catalytically active sites for oxidation of analytes. Simultaneous detection is performed best at a pH value of 7.0 and at peak potentials of 0.124 V (vs. SCE) for DA, 0.256 V for UA, 0.536 V for Tyr and 0.708 V for HCTZ. The respective detection limits are 0.04 mu M, 0.1 mu M, 0.6 mu M and 0.4 mu M. The results show that this graphene wall modified electrode is a promising tool for the design of sensitive, selective, and stable sensors.
引用
收藏
页码:1611 / 1619
页数:9
相关论文
共 35 条
[1]   Simultaneous determination of ascorbic acid, dopamine, uric acid and folic acid based on activated graphene/MWCNT nanocomposite loaded Au nanoclusters [J].
Abdelwahab, Adel A. ;
Shim, Yoon-Bo .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 :659-665
[2]   Association of Serum Uric Acid Level With Blood Pressure Variability in Newly Diagnosed Essential Hypertension [J].
Cagli, Kumral ;
Turak, Osman ;
Canpolat, Ugur ;
Ozcan, Firat ;
Tok, Derya ;
Mendi, Mehmet Ali ;
Oksuz, Fatih ;
Siriopol, Dimitrie ;
Veisa, Gabriel ;
Covic, Adrian ;
Kanbay, Mehmet .
JOURNAL OF CLINICAL HYPERTENSION, 2015, 17 (12) :929-935
[3]   Synthesis of Large-Area Graphene Layers on Poly-Nickel Substrate by Chemical Vapor Deposition: Wrinkle Formation [J].
Chae, Seung Jin ;
Guenes, Fethullah ;
Kim, Ki Kang ;
Kim, Eun Sung ;
Han, Gang Hee ;
Kim, Soo Min ;
Shin, Hyeon-Jin ;
Yoon, Seon-Mi ;
Choi, Jae-Young ;
Park, Min Ho ;
Yang, Cheol Woong ;
Pribat, Didier ;
Lee, Young Hee .
ADVANCED MATERIALS, 2009, 21 (22) :2328-+
[4]   glassy carbon electrode modified with a nickel(II) norcorrole complex and carbon nanotubes for simultaneous or individual determination of ascorbic acid, dopamine, and uric acid [J].
Deng, Keqin ;
Li, Xiaofang ;
Huang, Haowen .
MICROCHIMICA ACTA, 2016, 183 (07) :2139-2145
[5]   A novel and highly sensitive electrochemical sensor based on a high-quality modified graphene electrode for the determination of hydrochlorothiazide in pharmaceutical formulations and human plasma [J].
Er, Engin ;
Celikkan, Huseyin ;
Aksu, M. Levent ;
Erk, Nevin .
ANALYTICAL METHODS, 2015, 7 (21) :9254-9260
[6]   Simultaneous determination of captopril and hydrochlorothiazide on boron-doped diamond electrode by batch injection analysis with multiple pulse amperometric detection [J].
Gimenes, Denise Tofanello ;
Marra, Mariana Cardoso ;
de Freitas, Jhonys Machado ;
Abarza Munoz, Rodrigo Alejandro ;
Richter, Eduardo Mathias .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 212 :411-418
[7]   Mesoporous nitrogen containing carbon materials for the simultaneous detection of ascorbic acid, dopamine and uric acid [J].
Joshi, Anju ;
Schuhmann, Wolfgang ;
Nagaiah, Tharamani C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 :544-555
[8]  
Kannan P.K., 2016, Nanotechnology, V27, DOI DOI 10.1088/0957-4484/27/7/075504
[9]   A glassy carbon electrode modified with graphene and poly(acridine red) for sensing uric acid [J].
Li, Yang ;
Ran, Gu ;
Yi, Wen Jiao ;
Luo, Hong Qun ;
Li, Nian Bing .
MICROCHIMICA ACTA, 2012, 178 (1-2) :115-121
[10]   A glassy carbon electrode modified with MoS2 nanosheets and poly(3,4-ethylenedioxythiophene) for simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid [J].
Li, Ying ;
Lin, Hechun ;
Peng, Hui ;
Qi, Ruijuan ;
Luo, Chunhua .
MICROCHIMICA ACTA, 2016, 183 (09) :2517-2523