A Human Factors Perspective on the Use of Automated Aids in the Evaluation of NDT Data

被引:7
作者
Bertovic, Marija [1 ]
机构
[1] BAM Fed Inst Mat Res & Testing, Unter Eichen 87, D-12205 Berlin, Germany
来源
42ND ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 6TH EUROPEAN-AMERICAN WORKSHOP ON RELIABILITY OF NDE | 2016年 / 1706卷
关键词
DECISION-MAKING; BIAS; RELIABILITY; MISUSE; TRUST; COMPLACENCY; INSPECTION; DISUSE; PERFORMANCE; RELIANCE;
D O I
10.1063/1.4940449
中图分类号
O59 [应用物理学];
学科分类号
摘要
In comparison to manual NDT methods, mechanized NDT is considered to be more reliable for a number of reasons, one of which being that the role of the inspectors and, therewith, the potential for human error, have been reduced. However, human-automation interaction research suggests that in spite of its numerous benefits, automation can lead to new yet unknown risks. One of those risks is inappropriate reliance on automation, which can result in automation misuse and disuse. The aim of this study was to investigate the potential inappropriate use of automation (specifically the automated aids) in NDT addressing therewith the prevalent belief in the high reliability of automation held by the NDT community. To address this issue, 70 NDT trainees were asked to control the results of an eddy current data evaluation, allegedly provided by an automated aid, i.e. indication detection and sizing software. Seven errors were implemented into the task and it was measured to what extent the participants agreed with the aid. The results revealed signs of both misuse (agreeing with the aid even though it is incorrect) and disuse (disagreeing with the aid even though it is correct) of the aid that can affect the reliability with which inspections are carried out. Whereas misuse could be explained by a lower propensity to take risks and by a decreased verification behavior-possibly due to bias towards automation and complacent behavior-, disuse was assigned to problems in establishing the sizing criterion or to general difficulties in sizing. The implications of these results for the NDT praxis including suggestions for the decrease of automation bias are discussed.
引用
收藏
页数:16
相关论文
共 49 条
[1]   Effects of incorrect computer-aided detection (CAD) output on human decision-making in mammography [J].
Alberdi, E ;
Povyakalo, A ;
Strigini, L ;
Ayton, P .
ACADEMIC RADIOLOGY, 2004, 11 (08) :909-918
[2]  
[Anonymous], 2010, Statistik fur Humanund Sozialwissenschaftler
[3]  
[Anonymous], 2013, Report SKB TR-13-18
[4]   Misuse of automated decision aids:: Complacency, automation bias and the impact of training experience [J].
Bahner, J. Elin ;
Hueper, Anke-Dorothea ;
Manzey, Dietrich .
INTERNATIONAL JOURNAL OF HUMAN-COMPUTER STUDIES, 2008, 66 (09) :688-699
[5]  
Bainbridge L., 1987, NEW TECHNOLOGY HUMAN, P271, DOI DOI 10.1016/S1474-6670(17)62897-0
[6]  
Bertovic M., 2014, R1406 SKB
[7]  
Bertovic M., 2014, 1427252 SKB
[8]  
Bertovic M, 2015, THESIS TU BERLIN
[9]   Human Factors Perspective on the Reliability of NDT in Nuclear Applications [J].
Bertovic, Marija ;
Fahlbruch, Babette ;
Mueller, Christina .
MATERIALS TESTING, 2013, 55 (04) :243-253
[10]   Reliability of non-destructive test techniques in the inspection of pipelines used in the oil industry [J].
Carvalho, A. A. ;
Rebello, J. M. A. ;
Souza, W. V. ;
Sagrilo, L. V. S. ;
Soares, S. D. .
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2008, 85 (11) :745-751