Defining a New Standard for IVUS Optimized Drug Eluting Stent Implantation: The PRAVIO Study

被引:24
作者
Gerber, R. T. [1 ,2 ]
Latib, A. [2 ]
Lelasi, A. [2 ]
Cosgrave, J. [1 ]
Qasim, A. [1 ]
Airoldi, F. [2 ]
Chieffo, A. [2 ]
Montorfano, M. [2 ]
Carlino, M. [2 ]
Michev, I. [2 ]
Tobis, J. [3 ]
Colombo, A. [1 ,2 ]
机构
[1] EMO Ctr Cuore Columbus, I-20145 Milan, Italy
[2] Hosp San Raffaele, Catheterisat Lab, I-20132 Milan, Italy
[3] Univ Calif Los Angeles, Sch Med, Div Cardiol, Los Angeles, CA 90024 USA
关键词
IVUS guided stenting; drug eluting stents; complex lesions; INTRAVASCULAR ULTRASOUND GUIDANCE; CORONARY-ARTERY LESIONS; ANGIOGRAPHIC GUIDANCE; RESTENOSIS; THROMBOSIS; STENOSIS; DISEASE; TRIAL; UNDEREXPANSION; INTERVENTIONS;
D O I
10.1002/ccd.21973
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Preliminary Investigation to the Angiographic Versus IVUS Optimization Trial is a single center prospective observational intravascular ultrasound (IVUS) guided stent implantation study assessing new criteria for optimal drug eluting stent (DES) deployment. Background: IVUS assessment of DES often reveals underexpansion and malapposition. Optimal stent deployment is currently poorly defined and previous criteria may not be suitable in long and complex lesions. Methods: Optimization was defined as achieving >= 70% of the cross-sectional area (CSA) of the postdilation balloon. This criterion was applied in 113 complex lesions. The size of this balloon was calculated according to vessel media-to-media diameters at various sites inside the stented segment. The IVUS guided treated lesions were matched according to diabetes, vessel type, reference vessel diameter, minimum lumen diameter (MLD), and lesion length with a group of angiographic treated lesions to compare final MLD achieved. Results: Mean minimum stent CSA according to the postdilation balloon utilized was 4.62 mm(2), 6.26 mm(2), 7.87 mm(2), and 9.87 mm(2) for 2.5 mm, 3.0 mm, 3.5 mm, and 4 mm balloons, respectively. Final MLD (mm) was significantly larger in the IVUS compared to the angiographic-guided group (3.09 +/- 0.50 vs. 2.67 +/- 0.54; P < 0.0001). There were no procedural complications related to IVUS use. Conclusions: We propose new IVUS criteria based on vessel remodeling that results in an increment in the final MLD, compared to angiographic guidance, which is much larger than any previously published study. This criterion seems to be safely achievable. A proposed randomized study (angiographic vs. IVUS optimization trial) has been launched to test these concepts. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:348 / 356
页数:9
相关论文
共 31 条
[1]   Cutting balloon angioplasty for the treatment of in-stent restenosis: A matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty [J].
Adamian, M ;
Colombo, A ;
Briguori, C ;
Nishida, T ;
Marsico, F ;
Di Mario, C ;
Albiero, R ;
Moussa, I ;
Moses, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) :672-679
[2]   Mechanisms of residual lumen stenosis after high-pressure stent implantation -: A quantitative coronary angiography and intravascular ultrasound study [J].
Bermejo, J ;
Botas, J ;
García, E ;
Elízaga, J ;
Osende, J ;
Soriano, J ;
Abeytua, M ;
Delcán, JL .
CIRCULATION, 1998, 98 (02) :112-118
[3]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[4]   IVUS guidance results in lower in-stent restenosis: A chapter for a history book? [J].
Colombo, A .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 59 (03) :322-323
[5]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[6]   Late incomplete stent apposition after drug-eluting stent implantation: a true risk factor or "an innocent bystander"? [J].
Colombo, Antonio ;
Latib, Azeem .
HEART, 2008, 94 (03) :253-254
[7]   Intravascular ultrasound assessment of drug-eluting stent expansion [J].
Costa, Jose de Ribamar, Jr. ;
Mintz, Gary S. ;
Carlier, Stephane G. ;
Fujii, Kenichi ;
Sano, Koichi ;
Kimura, Masashi ;
Tanaka, Kaoru ;
Costa, Ricardo A. ;
Lui, Joanna ;
Na, Yingbo ;
Castellanos, Celia ;
Biro, Sinan ;
Moussa, Issam ;
Stone, Gregg W. ;
Moses, Jeffrey W. ;
Leon, Martin B. .
AMERICAN HEART JOURNAL, 2007, 153 (02) :297-303
[8]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[9]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[10]   Vascular responses to drug eluting stents - Importance of delayed healing [J].
Finn, Aloke V. ;
Nakazawa, Gaku ;
Joner, Michael ;
Kolodgie, Frank D. ;
Mont, Erik K. ;
Gold, Herman K. ;
Virmani, Renu .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2007, 27 (07) :1500-1510