High-power solid-state amplifier for superconducting radio frequency cavity test facility

被引:0
作者
Jain, Akhilesh [1 ]
Sharma, Deepak Kumar [1 ]
Gupta, Alok Kumar [1 ]
Pathak, Kriti [1 ]
Lad, M. R. [1 ]
机构
[1] Raja Ramanna Ctr Adv Technol, Radio Frequency Syst Div, Indore 452013, India
关键词
Efficiency;
D O I
10.1063/5.0030896
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A horizontal test facility is set up at the Raja Ramanna Centre for Advanced Technology to test the superconducting radio frequency dressed cavities. Along with the cryomodule, control instrumentation, and the power coupler, this facility incorporates a high-power solid-state amplifier for establishing the desired cavity voltage gradient during the testing. This article describes the design, construction, rigorous testing, and measured results of this high-power solid-state radio frequency amplifier and its constituent components. Its maximum output power is 36 kW (average) at the operating frequency of 650 MHz. Its main features are its modular and scalable design with in-house developed constituent components. These components include 500 W, 20 dB gain modules, novel two-tier radial dividers, combiners, power sensors, and aperture-coupled directional couplers. Their excellent reprise performance for the multiple quantities confirms the design methodology presented here. The measured wall plug efficiency of this 36 kW amplifier is 43.6%, and its power gain is 86 dB. The designed radial combiner is highly efficient (power-combining efficiency of 98.4%), and the directional coupler exhibits a very low loss (insertion loss of 0.05 dB).
引用
收藏
页数:11
相关论文
共 26 条
[1]  
[Anonymous], 2012, REV ACCELERATOR SCI
[2]  
Ansys, High frequency structure simulation software
[3]   Grazing Zero [J].
Cripps, Steve C. .
IEEE MICROWAVE MAGAZINE, 2010, 11 (07) :24-34
[4]   Indus-2 Synchrotron Radiation Source: current status and utilization [J].
Deb, S. K. ;
Singh, Gurnam ;
Gupta, P. D. .
11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
[5]   Feedback compensated 10 kW solid-state pulsed power amplifier at 352 MHz for particle accelerators [J].
Duc, L. Hoang ;
Jobs, M. ;
Lofnes, T. ;
Ruber, R. ;
Olsson, J. ;
Dancila, D. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (10)
[6]  
Dye Norman., 2001, RADIO FREQUENCY TRAN, Vsecond
[7]   A Compact 500 MHz 65 kW Solid-State Power Amplifier for Accelerator Applications [J].
Gaspar, M. ;
Garvey, T. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (02) :699-706
[8]  
Gupta A.K., 2019, PAC 19
[9]  
Gupta A.K., 2018, PAC 18
[10]  
Gupta AK, 2018, 2018 2ND INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ENVIRONMENT: TOWARDS SMART TECHNOLOGY (ICEPE)