Voltammetric studies of sumatriptan on the surface of pyrolytic graphite electrode modified with multi-walled carbon nanotubes decorated with silver nanoparticles

被引:81
作者
Ghalkhani, Masoumeh [1 ]
Shahrokhian, Saeed [1 ,2 ]
Ghorbani-Bidkorbeh, Fatemeh [1 ]
机构
[1] Sharif Univ Technol, Dept Chem, Tehran 111559516, Iran
[2] Sharif Univ Technol, Inst Nanosci & Technol, Tehran 111559516, Iran
关键词
Sumatriptan; Decorated multi-walled carbon nanotube; Silver nanoparticle; Modified electrode; Voltammetry; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; SELECTIVE DETERMINATION; HUMAN PLASMA; VALIDATION; COMPOSITE; SUCCINATE; OXIDATION; DOPAMINE; ASSAY;
D O I
10.1016/j.talanta.2009.06.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multi-walled carbon nanotube decorated with silver nanoparticles (AgNPs-MWCNT) is used as an effective strategy for modification of the surface of pyrolytic graphite electrode (PGE). This modification procedure improved colloidal dispersion of the decorated MWCNTs in water, affording uniform and stable thin films for altering the surface properties of the working electrode. Robust electrode for sensing applications is obtained in a simple solvent evaporation process. The electrochemical behavior of sumatriptan (Sum) at the bare PGE and AgNPs-MWCNT modified PGE is investigated. The results indicate that the AgNPs-MWCNT modified PCE significantly enhanced the oxidation peak current of Sum. A remarkable enhancement in microscopic area of the electrode together with strong adsorption of Sum on the surface of the modified electrode resulted in a considerable increase in the peak current of Sum. Experimental parameters, such as scan rate, pH, accumulation conditions and amount of the modifier used on the PCE surface are optimized by monitoring the CV responses toward Sum. It is found that a maximum current response can be obtained at pH 7.4 after accumulation at open circuit for 150 s. Further experiments demonstrated that the oxidative peak currents increased linearly with Sum concentration in the range of 8.0 x 10(-8)-1.0 X 10(-4) mol L-1 with a detection limit of 4.0 x 10(-8) mol L-1. The modified electrode showed high sensitivity, selectivity, long-term stability and remarkable voltammetric reproducibility in response to Sum. These excellent properties make the prepared sensor suitable for the analysis in pharmaceutical and clinical preparations. The modified electrode was successfully applied for the accurate determination of trace amounts of Sum in pharmaceutical preparations. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 32 条
[1]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[2]  
ALTRIA KD, 1993, ANAL PROC, V30, P363
[3]   Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites [J].
Banks, CE ;
Davies, TJ ;
Wildgoose, GG ;
Compton, RG .
CHEMICAL COMMUNICATIONS, 2005, (07) :829-841
[4]   Reversible sidewall functionalization of buckytubes [J].
Boul, PJ ;
Liu, J ;
Mickelson, ET ;
Huffman, CB ;
Ericson, LM ;
Chiang, IW ;
Smith, KA ;
Colbert, DT ;
Hauge, RH ;
Margrave, JL ;
Smalley, RE .
CHEMICAL PHYSICS LETTERS, 1999, 310 (3-4) :367-372
[5]   Validation of a liquid chromatographic tandem mass spectrometric method for the determination of sumatriptan in human biological fluids [J].
Cheng, KN ;
Redrup, MJ ;
Barrow, A ;
Williams, PN .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (03) :399-408
[6]  
Deshpande, 1998, INDIAN DRUGS, V35, P404
[7]   Fully automated assay for the determination of sumatriptan in human serum using solid-phase extraction and high-performance liquid chromatography with electrochemical detection [J].
Dunne, M ;
Andrew, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (06) :721-726
[8]   Hydrophobic anchoring of monolayer-protected gold nanoclusters to carbon nanotubes [J].
Ellis, AV ;
Vjayamohanan, K ;
Goswaimi, R ;
Chakrapani, N ;
Ramanathan, LS ;
Ajayan, PM ;
Ramanath, G .
NANO LETTERS, 2003, 3 (03) :279-282
[9]   High-performance liquid chromatographic determination of sumatriptan after in vitro transdermal diffusion studies [J].
Femenía-Font, A ;
Merino, V ;
Rodilla, V ;
López-Castellano, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (03) :621-626
[10]   Determination of sumatriptan succinate in human plasma by highperformance liquid chromatography with coulometric detection and utilization of solid-phase extraction [J].
Franklin, M ;
Odontiadis, J ;
Clement, EM .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (02) :416-420