Stereotactic Transcranial Focused Ultrasound Targeting System for Murine Brain Models

被引:7
作者
Choi, Sang Won [1 ]
Gerhardson, Tyler, I [1 ]
Duclos, Sarah E. [1 ]
Surowiec, Rachel K. [2 ,3 ]
Scheven, Ulrich M. [4 ]
Galban, Stefanie [2 ,3 ]
Lee, Fred T., Jr. [5 ]
Greve, Joan M. [1 ]
Balter, James M. [6 ]
Hall, Timothy L. [1 ]
Xu, Zhen [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Ctr Mol Imaging, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[5] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[6] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
Accuracy; brain tumors; focused ultrasound (FUS); glioblastoma; histotripsy; mouse; stereotactic; transcranial; NEURONAVIGATION; HISTOTRIPSY; ABLATION; BARRIER;
D O I
10.1109/TUFFC.2020.3012303
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An inexpensive, accurate focused ultrasound stereotactic targeting method guided by pretreatment magnetic resonanceimaging (MRI) images formurine brainmodels is presented. An uncertainty of each sub-component of the stereotactic system was analyzed. The entire system was calibrated using clot phantoms. The targeting accuracy of the system was demonstrated with an in vivo mouse glioblastoma ( GBM) model. The accuracy was quantified by the absolute distance difference between the prescribed and ablated points visible on the pre treatment and post-treatment MR images, respectively. A precalibration phantom study (N = 6) resulted in an error of 0.32 +/- 0.31, 0.72 +/- 0.16, and 1.06 +/- 0.38 mm in axial, lateral, and elevational axes, respectively. A postcalibration phantom study (N = 8) demonstrated a residual error of 0.09 +/- 0.01, 0.15 +/- 0.09, and 0.47 +/- 0.18 mm in axial, lateral, and elevational axes, respectively. The calibrated system showed significantly reduced (p < 0.05) error of 0.20 +/- 0.21, 0.34 +/- 0.24, and 0.28 +/- 0.21mmin axial, lateral, and elevationalaxes, respectively, in the in vivo GBM tumor-bearing mice (N = 10).
引用
收藏
页码:154 / 163
页数:10
相关论文
共 46 条
[1]  
[Anonymous], SPEED SOUND
[2]  
[Anonymous], 2016, THESIS
[3]   FOR WHOM THE BUBBLE GROWS: PHYSICAL PRINCIPLES OF BUBBLE NUCLEATION AND DYNAMICS IN HISTOTRIPSY ULTRASOUND THERAPY [J].
Bader, Kenneth B. ;
Vlaisavljevich, Eli ;
Maxwell, Adam D. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (05) :1056-1080
[4]   Stereotactic Intracranial Implantation and In vivo Bioluminescent Imaging of Tumor Xenografts in a Mouse Model System of Glioblastoma Multiforme [J].
Baumann, Brian C. ;
Dorsey, Jay F. ;
Benci, Joseph L. ;
Joh, Daniel Y. ;
Kao, Gary D. .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (67)
[5]   Alzheimer Disease in a Mouse Model: MR Imaging-guided Focused Ultrasound Targeted to the Hippocampus Opens the Blood-Brain Barrier and Improves Pathologic Abnormalities and Behavior [J].
Burgess, Alison ;
Dubey, Sonam ;
Yeung, Sharon ;
Hough, Olivia ;
Eterman, Naomi ;
Aubert, Isabelle ;
Hynynen, Kullervo .
RADIOLOGY, 2014, 273 (03) :736-745
[6]  
Carter M., 2015, GUIDE RES TECHNIQUES, P73, DOI [10.1016/b978-0-12-800511-8.00003-4, DOI 10.1016/B978-0-12-800511-8.00003-4]
[7]   An MRI-compatible system for focused ultrasound experiments in small animal models [J].
Chopra, Rajiv ;
Curiel, Laura ;
Staruch, Robert ;
Morrison, Laetitia ;
Hynynen, Kullervo .
MEDICAL PHYSICS, 2009, 36 (05) :1867-1874
[8]   Focused Ultrasound Immunotherapy for Central Nervous System Pathologies: Challenges and Opportunities [J].
Curley, Colleen T. ;
Sheybani, Natasha D. ;
Bullock, Timothy N. ;
Price, Richard J. .
THERANOSTICS, 2017, 7 (15) :3608-3623
[9]  
da Costa L., 2015, J THER ULTRASOUND, V3
[10]   The targeting accuracy of a preclinical MRI-guided focused ultrasound system [J].
Ellens, N. P. K. ;
Kobelevskiy, I. ;
Chau, A. ;
Waspe, A. C. ;
Staruch, R. M. ;
Chopra, R. ;
Hynynen, K. .
MEDICAL PHYSICS, 2015, 42 (01) :430-439