MRI-Guided HIFU Methods for the Ablation of Liver and Renal Cancers

被引:41
作者
de Senneville, Baudouin Denis [1 ,2 ]
Moonen, Chrit [1 ]
Ries, Mario [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept UMCU, Imaging Div, Utrecht, Netherlands
[2] Univ Bordeaux, Math Inst Bordeaux, Dept CNRS, UMR CNRS 5251, F-33400 Talence, France
来源
THERAPEUTIC ULTRASOUND | 2016年 / 880卷
关键词
Real-time; MRI HIFU; Tumor ablation; INTENSITY-FOCUSED ULTRASOUND; RESPIRATORY MOTION; ONLINE CORRECTION; SHIFT METHOD; TIME; THERMOMETRY; FIELD; REFERENCELESS; FEASIBILITY; TUMORS;
D O I
10.1007/978-3-319-22536-4_3
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
MRI-guided High Intensity Focused Ultrasound (MRI-HIFU) is a promising method for the non-invasive ablation of pathological tissue in many organs, including mobile organs such as liver and kidney. The possibility to locally deposit thermal energy in a non-invasive way opens a path towards new therapeutic strategies with improved reliability and reduced associated trauma, leading to improved efficacy, reduced hospitalization and costs. Liver and kidney tumors represent a major health problem because not all patients are suitable for curative treatment with surgery. Currently, radio-frequency is the most used method for percutaneous ablation. The development of a completely non-invasive method based on MR guided high intensity focused ultrasound (HIFU) treatments is of particular interest due to the associated reduced burden for the patient, treatment related patient morbidity and complication rate. The objective of MR-guidance is hereby to control heat deposition with HIFU within the targeted pathological area, despite the physiological motion of these organs, in order to provide an effective treatment with a reduced duration and an increased level of patient safety. Regarding this, several technological challenges have to be addressed: Firstly, the anatomical location of both organs within the thoracic cage requires inter-costal ablation strategies, which preserve the therapeutic efficiency, but prevent undesired tissue damage to the ribs and the intercostal muscle. Secondly, both therapy guidance and energy deposition have to be rendered compatible with the continuous physiological motion of the abdomen.
引用
收藏
页码:43 / 63
页数:21
相关论文
共 115 条
[1]  
[Anonymous], 2011, GLOB CANC FACTS FIG, V2nd
[2]  
Arnold P, 2011, LECT NOTES COMPUT SC, V6892, P623, DOI 10.1007/978-3-642-23629-7_76
[3]   Respiratory-Gated MRgHIFU in Upper Abdomen Using an MR-Compatible In-Bore Digital Camera [J].
Auboiroux, Vincent ;
Petrusca, Lorena ;
Viallon, Magalie ;
Muller, Arnaud ;
Terraz, Sylvain ;
Breguet, Romain ;
Montet, Xavier ;
Becker, Christoph D. ;
Salomir, Rares .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[4]   Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility study ex vivo [J].
Auboiroux, Vincent ;
Petrusca, Lorena ;
Viallon, Magalie ;
Goget, Thomas ;
Becker, Christoph D. ;
Salomir, Rares .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (10) :N159-N171
[5]   Transcostal high-intensity-focused ultrasound:: ex vivo adaptive focusing feasibility study [J].
Aubry, J-F ;
Pernot, M. ;
Marquet, F. ;
Tanter, M. ;
Fink, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11) :2937-2951
[6]   In Vivo T2-Based MR Thermometry in Adipose Tissue Layers for High-Intensity Focused Ultrasound Near-Field Monitoring [J].
Baron, Paul ;
Ries, Mario ;
Deckers, Roel ;
de Greef, Martijn ;
Tanttu, Jukka ;
Kohler, Max ;
Viergever, Max A. ;
Moonen, Chrit T. W. ;
Bartels, Lambertus W. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) :1057-1064
[7]   PERFORMANCE OF OPTICAL-FLOW TECHNIQUES [J].
BARRON, JL ;
FLEET, DJ ;
BEAUCHEMIN, SS .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) :43-77
[8]   FOCUSING OF HIGH-INTENSITY ULTRASOUND THROUGH THE RIB CAGE USING A THERAPEUTIC RANDOM PHASED ARRAY [J].
Bobkova, Svetlana ;
Gavrilov, Leonid ;
Khokhlova, Vera ;
Shaw, Adam ;
Hand, Jeffrey .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (06) :888-906
[9]   A hybrid computational model for ultrasound phased-array heating in presence of strongly scattering obstacles [J].
Botros, YY ;
Volakis, JL ;
VanBaren, P ;
Ebbini, ES .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (11) :1039-1050
[10]   Three-dimensional liver motion tracking using real-time two-dimensional MRI [J].
Brix, Lau ;
Ringgaard, Steffen ;
Sorensen, Thomas Sangild ;
Poulsen, Per Rugaard .
MEDICAL PHYSICS, 2014, 41 (04)