Rapid identification of metallothionein isoforms in liver cytosol fraction by capillary zone electrophoresis using EDTA

被引:10
|
作者
Kubo, K
Sakita, Y
Otaki, N
Kimura, M
Minami, T
机构
[1] Kinki Univ, Toyo Oka Jr Coll, Dept Living Sci & Program Proc, Toyoake 6688580, Japan
[2] Kinki Univ, Fac Pharmaceut Sci, Osaka 5578502, Japan
[3] Natl Inst Ind Hlth, Dept Occupat Dis, Kawasaki, Kanagawa 2148585, Japan
[4] Keio Univ, Sch Med, Dept Mol Biol, Tokyo 1600016, Japan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2000年 / 742卷 / 01期
关键词
metallothionein; EDTA;
D O I
10.1016/S0378-4347(00)00144-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Identification of metallothionein (MT) isoforms on capillary zone electrophoresis (CZE) analysis was studied using a linear polyacrylamide-coated capillary at pH 7.4 and EDTA. The CZE system was able to separate standard (purified and commercially available) MT specimens into their isoforms within 10 min. The peaks of MT-1 and MT-2 isoforms disappeared on addition of EDTA to the specimen, and the disappearance was shown to be time-dependent and dose-dependent, although the reason why the peaks decreased is still unclear. A heat-treated cytosol fraction prepared from Zn-injected mouse liver showed many major and minor peaks on CZE analysis. Two major peaks were identified to be MT-1 and MT-2, respectively, by co-injection with the purified MT isoforms. When EDTA was added to the cytosol fraction, the two major peaks, MT-1 and MT-2, and three other minor peaks disappeared time-dependently. Therefore, each MT isoform in the cytosol fraction can be identified by the addition of EDTA, also the peaks are identified by the corresponding migration times of purified MTs. Unknown substances like MT sub-isoforms may also be detected, although this question warrants clarification. From these results, it was concluded that the addition of EDTA is useful for identification of MT isoforms in cytosol fractions on CZE analysis. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 198
页数:6
相关论文
共 50 条
  • [1] Separation of metallothionein isoforms of mouse liver cytosol by capillary zone electrophoresis
    Minami, T
    Yoshita, C
    Tanaka, M
    Kubo, K
    Okabe, N
    Okazaki, Y
    TALANTA, 1998, 46 (02) : 347 - 354
  • [2] Quantitation of metallothionein isoforms in mouse liver on capillary zone electrophoresis
    Minami, T
    Tohno, Y
    Okazaki, Y
    Kubo, K
    Otaki, N
    Kimura, M
    ANALYTICA CHIMICA ACTA, 1998, 372 (1-2) : 241 - 247
  • [3] Stability of metallothionein isoforms by capillary zone electrophoresis
    Minami, T
    Sakita, Y
    Kub, K
    Okabe, N
    Okazaki, Y
    Tohno, S
    Tohno, Y
    Yamada, M
    CELLULAR AND MOLECULAR BIOLOGY, 1998, 44 (02) : 285 - 292
  • [4] Identification of metallothionein isoforms with capillary zone electrophoresis using a polyacrylamide-coated tube
    Minami, T
    Matsubara, H
    Ohigashi, M
    Otaki, N
    Kimura, M
    Kubo, K
    Okabe, N
    Okazaki, Y
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 685 (02): : 353 - 359
  • [5] SEPARATION OF METALLOTHIONEIN ISOFORMS BY CAPILLARY ZONE ELECTROPHORESIS
    BEATTIE, JH
    RICHARDS, MP
    SELF, R
    JOURNAL OF CHROMATOGRAPHY, 1993, 632 (1-2): : 127 - 135
  • [6] Identification of metallothionein isoforms on capillary zone electrophoresis by adding anti-metallothionein antibody
    Kubo, K
    Sakita, Y
    Okazaki, Y
    Otaki, N
    Kimura, M
    Minami, T
    JOURNAL OF CHROMATOGRAPHY B, 1999, 736 (1-2): : 185 - 190
  • [7] Effect of heat treatment on metallothionein isoforms using capillary zone electrophoresis
    Kubo, K
    Sakita, Y
    Minami, T
    ANALUSIS, 2000, 28 (05) : 366 - 369
  • [8] APPLICATION OF CAPILLARY ZONE ELECTROPHORESIS TO THE SEPARATION OF METALLOTHIONEIN ISOFORMS
    RICHARDS, MP
    BEATTIE, JH
    SELF, R
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10): : 2113 - 2128
  • [9] Separation of metallothionein isoforms and identification of complexed metals by capillary zone electrophoresis using diode array detection
    Virtanen, V
    Bordin, G
    Rodriguez, AR
    TRACE ELEMENTS IN MAN AND ANIMALS 10, 2000, : 1103 - 1105
  • [10] APPLICATION OF CAPILLARY ZONE ELECTROPHORESIS (CZE) TO THE SEPARATION OF METALLOTHIONEIN ISOFORMS
    RICHARDS, MP
    BEATTIE, JH
    SELF, R
    FASEB JOURNAL, 1992, 6 (04): : A1093 - A1093