Ultrasound Transducer and System for Real-Time Simultaneous Therapy and Diagnosis for Noninvasive Surgery of Prostate Tissue

被引:25
作者
Jeong, Jong Seob [1 ]
Chang, Jin Ho [1 ]
Shung, K. Kirk [1 ]
机构
[1] Univ So Calif, Dept Biomed Engn, NIH Resource Ctr Med Ultrason Transducer Technol, Los Angeles, CA 90089 USA
关键词
INTENSITY FOCUSED ULTRASOUND; CODED EXCITATION; DESIGN; ARRAYS;
D O I
10.1109/TUFFC.2009.1267
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
For noninvasive treatment of prostate tissue using high-intensity focused ultrasound this paper proposes a design of an integrated multifunctional confocal phased array (IMCPA) and a strategy to perform both imaging and therapy simultaneously with this array. IMCPA is composed of triple-row phased arrays: a 6-MHz array in the center row for imaging and two 4-MHz arrays in the outer rows for therapy. Different types of piezoelectric materials and stack configurations may be employed to maximize their respective functionalities, i.e., therapy and imaging. Fabrication complexity of IMCPA may be reduced by assembling already constructed arrays. In IMCPA, reflected therapeutic signals may corrupt the quality of imaging signals received by the center-row array. This problem can be overcome by implementing a coded excitation approach and/or a notch filter when B-mode images are formed during therapy. The 13-bit Barker code, which is a binary code with unique autocorrelation properties, is preferred for implementing coded excitation, although other codes may also be used. From both Field II simulation and experimental results, we verified whether these remedial approaches would make it feasible to simultaneously carry out imaging and therapy by IMCPA. The results showed that the 13-bit Barker code with 3 cycles per bit provided acceptable performances. The measured -6 dB and -20 dB range mainlobe widths were 0.52 mm and 0.91 mm, respectively, and a range sidelobe level was measured to be -48 dB regardless of whether a notch filter was used. The 13-bit Barker code with 2 cycles per bit yielded -6 dB and -20 dB range mainlobe widths of 0.39 mm and 0.67 mm. Its range sidelobe level was found to be -40 dB after notch filtering. These results indicate the feasibility of the proposed transducer design and system for real-time imaging during therapy.
引用
收藏
页码:1913 / 1922
页数:10
相关论文
共 41 条
[1]  
[Anonymous], 2006, EAU-EBU Updat Ser, DOI DOI 10.1016/J.EEUS.2006.01.002
[2]   International recommendations and guidelines for the safe use of diagnostic ultrasound in medicine [J].
Barnett, SB ;
Ter Haar, GR ;
Ziskin, MC ;
Rott, HD ;
Duck, FA ;
Maeda, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :355-366
[3]   High-intensity focused ultrasound for the treatment of localized prostate cancer: 5-year experience [J].
Blana, A ;
Walter, B ;
Rogenhofer, S ;
Wieland, WF .
UROLOGY, 2004, 63 (02) :297-300
[4]   Dual-mode ultrasound transducer for image-guided interstitial thermal therapy [J].
Bouchoux, Guillaume ;
Lafon, Cyril ;
Berriet, Remi ;
Chapelon, Jean Yves ;
Fleury, Gerard ;
Cathignol, Dominique .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (04) :607-616
[5]  
Carney R., 1963, IEEE Trans. Space Electron. Telem, V9, P109
[6]   In vivo demonstration of noninvasive thermal surgery of the liver and kidney using an ultrasonic phased array [J].
Daum, DR ;
Smith, NB ;
King, R ;
Hynynen, K .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (07) :1087-1098
[7]   Dual-mode ultrasound phased arrays for image-guided surgery [J].
Ebbini, Emad S. ;
Yao, Hui ;
Shrestha, Ajay .
ULTRASONIC IMAGING, 2006, 28 (02) :65-82
[9]   CONTROL OF THE NECROSED TISSUE VOLUME DURING NONINVASIVE ULTRASOUND SURGERY USING A 16-ELEMENT PHASED-ARRAY [J].
FAN, XB ;
HYNYNEN, K .
MEDICAL PHYSICS, 1995, 22 (03) :297-306
[10]  
Fiore D., 1996, P IEEE ULTR S, P531