Physio-optical considerations in the design of fetal pulse oximetry sensors

被引:21
作者
Mannheimer, PD
Fein, ME
Casciani, JR
机构
来源
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY | 1997年 / 72卷
关键词
medical optics; pulse oximetry; tissue optics; low saturation;
D O I
10.1016/S0301-2115(97)02713-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Pulse oximetry is being investigated as a potentially useful tool for assessing the well-being of the fetus during labor and delivery. Two commonly made simplifying assumptions in the basic mathematics of pulse oximetry, however, strongly influence the accuracy of the measurement if not accounted for in the sensor's design. Accurate oximeter performance requires a good overlap in light penetration at the wavelengths utilized in order to minimize the effects of tissue heterogeneity. Furthermore, path length changes arising from variations in tissue absorbance must be balanced at the two wavelengths or else calibration bias may result. The effects of light scattering within the tissue need to be considered over the range of oxygen saturation in which best operation of the system is desired. For oximeters designed to monitor air-breathing patients at high saturation, the conventional choice of emitter wavelengths optimizes both accuracy and measurement sensitivity. For the lower oxygen saturations typical in the fetus during labor, numerical modeling suggests that significantly better accuracy can be expected when a far red and near infrared emitter pair are used, even though the saturation measurement sensitivity is somewhat reduced. (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:S9 / S19
页数:11
相关论文
共 26 条
[1]   MODEL FOR PHOTON MIGRATION IN TURBID BIOLOGICAL MEDIA [J].
BONNER, RF ;
NOSSAL, R ;
HAVLIN, S ;
WEISS, GH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (03) :423-432
[2]   CORRELATION OF LASER DOPPLER WAVE PATTERNS WITH UNDERLYING MICROVASCULAR ANATOMY [J].
BRAVERMAN, IM ;
KEH, A ;
GOLDMINZ, D .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1990, 95 (03) :283-286
[3]   FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY [J].
BUSCHMANN, J ;
RALL, G ;
KNITZA, R .
LANCET, 1992, 339 (8793) :615-615
[4]   Fetal pulse oximetry - A preliminary report on sensor precision determined by dual sensor studies [J].
Davies, MG ;
Greene, KR .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 :S35-S41
[5]  
DILDY GA, 1993, OBSTET GYNECOL, V81, P630
[6]   INTRAPARTUM FETAL PULSE OXIMETRY - FETAL OXYGEN-SATURATION TRENDS DURING LABOR AND RELATION TO DELIVERY OUTCOME [J].
DILDY, GA ;
VANDENBERG, PP ;
KATZ, M ;
CLARK, SL ;
JONGSMA, HW ;
NIJHUIS, JG ;
LOUCKS, CA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 171 (03) :679-684
[7]   PERCENTILES FOR GAS VALUES IN HUMAN UMBILICAL-CORD BLOOD [J].
ESKES, TKAB ;
JONGSMA, HW ;
HOUX, PCW .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1983, 14 (05) :341-346
[8]  
Flewelling R., 1995, BIOMEDICAL ENG HDB, P1346
[9]  
GRAAFF R, 1993, THESIS RIJKSUNIVERSI
[10]  
HASELGROVE J, 1991, P SOC PHOTO-OPT INS, V1431, P30, DOI 10.1117/12.44175