Lever-arm and boresight correction, and field of view determination of a spectroradiometer mounted on an unmanned aircraft system

被引:21
作者
Gautam, Deepak [1 ,2 ]
Lucieer, Arko [1 ]
Watson, Christopher [1 ]
McCoull, Colin [1 ]
机构
[1] Univ Tasmania, Sch Technol Environm & Design, Discipline Geog & Spatial Sci, Hobart, Tas 7005, Australia
[2] Univ Adelaide, Fac Sci, Sch Agr Food & Wine, Adelaide, SA 5064, Australia
基金
澳大利亚研究理事会;
关键词
Aerial spectroscopy; UAS; UAV; Boresight; Lever-arm; Field of view; Spectroradiometer; Footprint; Geolocation; INDUCED CHLOROPHYLL FLUORESCENCE; HYPERSPECTRAL IMAGERY; CAMERA CALIBRATION; SELF-CALIBRATION; LIDAR SYSTEM; UAV; SPECTROSCOPY; PHOTOSYNTHESIS; PHOTOGRAMMETRY; TEMPERATURE;
D O I
10.1016/j.isprsjprs.2019.06.016
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
This study addresses the correction of lever-arm offset and boresight angle, and field of view (FOV) determination to enable accurate footprint determination of a spectroradiometer mounted on an unmanned aircraft system (UAS). To characterise the footprint, an accurate determination of the spectroradiometer position and orientation (pose) must be acquired with a global navigation satellite system (GNSS) and an inertial measurement unit (IMU). Accurate pose estimation requires an accurate lever-arm and boresight correction between the pose measuring sensors and the spectroradiometer. Similarly, the spectroradiometer FOV is required to determine the footprint size as a function of above ground level (AGL) flying height. The system used in this study consists of an IMU with dual-frequency and dual-antenna GNSS receiver, a machine vision camera, and a point measuring spectroradiometer (Ocean Optics QE Pro). The lever-arm offset was determined from a scaled 3D point cloud of the system, created using photos of the airframe and processed with the structure-from-motion (SfM) algorithm. The boresight angles were estimated with stationary experiments by computing the difference between the orientations of the IMU, the spectroradiometer, and the camera. The orientation of the spectroradiometer was determined by moving a spectrally distinct target into the FOV. The orientation of IMU was measured by averaging its readings during the stationary epoch, while SfM was employed as an independent technique to estimate the orientation of the camera. The footprint of the spectroradiometer for a combination of AGL height and Gershun tube aperture ring was determined experimentally, enabling computation of the effective FOV. In-flight validation of the lever-arm and boresight correction was performed by comparing the corrected pose of the co-mounted camera with the pose derived from SfM as the reference. Our experimental results demonstrate that controlled determination and correction of lever-arm and boresight increases the pose estimation accuracy and thereby supports the direct georeferencing of a UAS-mounted spectroradiometer point observation.
引用
收藏
页码:25 / 36
页数:12
相关论文
共 49 条
[1]   Quantitative Remote Sensing at Ultra-High Resolution with UAV Spectroscopy: A Review of Sensor Technology, Measurement Procedures, and Data Correction Workflows [J].
Aasen, Helge ;
Honkavaara, Eija ;
Lucieer, Arko ;
Zarco-Tejada, Pablo J. .
REMOTE SENSING, 2018, 10 (07)
[2]   Generating 3D hyperspectral information with lightweight UAV snapshot cameras for vegetation monitoring: From camera calibration to quality assurance [J].
Aasen, Helge ;
Burkart, Andreas ;
Bolten, Andreas ;
Bareth, Georg .
ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2015, 108 :245-259
[3]   Meta-analysis assessing potential of steady-state chlorophyll fluorescence for remote sensing detection of plant water, temperature and nitrogen stress [J].
Ac, Alexander ;
Malenovsky, Zbynek ;
Olejnickova, Julie ;
Galle, Alexander ;
Rascher, Uwe ;
Mohammed, Gina .
REMOTE SENSING OF ENVIRONMENT, 2015, 168 :420-436
[4]  
[Anonymous], THESIS
[5]  
[Anonymous], THESIS
[6]   A Novel UAV-Based Ultra-Light Weight Spectrometer for Field Spectroscopy [J].
Burkart, Andreas ;
Cogliati, Sergio ;
Schickling, Anke ;
Rascher, Uwe .
IEEE SENSORS JOURNAL, 2014, 14 (01) :62-67
[7]  
Caras T., 2011, J SPECTRAL IMAGING, V2, P1, DOI DOI 10.1255/JSI.2011.A1
[8]   A New Calibration Method Using Low Cost MEM IMUs to Verify the Performance of UAV-Borne MMS Payloads [J].
Chiang, Kai-Wei ;
Tsai, Meng-Lun ;
Naser, El-Sheimy ;
Habib, Ayman ;
Chu, Chien-Hsun .
SENSORS, 2015, 15 (03) :6560-6585
[9]   The Development of an UAV Borne Direct Georeferenced Photogrammetric Platform for Ground Control Point Free Applications [J].
Chiang, Kai-Wei ;
Tsai, Meng-Lun ;
Chu, Chien-Hsun .
SENSORS, 2012, 12 (07) :9161-9180
[10]   Continuous and long-term measurements of reflectance and sun-induced chlorophyll fluorescence by using novel automated field spectroscopy systems [J].
Cogliati, S. ;
Rossini, M. ;
Julitta, T. ;
Meroni, M. ;
Schickling, A. ;
Burkart, A. ;
Pinto, F. ;
Rascher, U. ;
Colombo, R. .
REMOTE SENSING OF ENVIRONMENT, 2015, 164 :270-281