Voltammetric Determination of Tetracycline by Using Multi-Wall Carbon Nanotube - Ionic Liquid Film Coated Glassy Carbon Electrode

被引:0
作者
Guo, Gaiping [1 ]
Zhao, Faqiong [1 ]
Xiao, Fei [1 ]
Zeng, Baizhao [1 ]
机构
[1] Wuhan Univ, Coll Chem & Mol Sci, Wuhan 430072, Peoples R China
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2009年 / 4卷 / 09期
基金
中国国家自然科学基金;
关键词
Tetracycline; ionic liquid; carbon nanotube; voltammetry; SOLID-PHASE EXTRACTION; CHROMATOGRAPHY; RESIDUES; ANTIBIOTICS; BIOSENSOR; WATER; MILK;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A voltammetric method was developed for the determination of tetracycline (TC) by using an ionic liquid (IL, 1-octyl-3-methylimidazolium-hexafluorophosphate) - multi-wall carbon nanotube (MWNT) film coated glassy carbon electrode (GCE). Experiment showed that both IL and MWNT could facilitate the TC oxidation. Thus on the electrode TC exhibited a sensitive anode peak at 0.54 V (vs. SCE) in pH 7.0 phosphate buffer solutions. Under the optimized experimental conditions, the peak current was linear to TC concentration in the range of 1.1x10(-7)-2.2x10(-5) M for 150 s accumulation. The electrode had good reproducibility. It was successfully applied to the detection of TC in egg and pharmaceutical samples.
引用
收藏
页码:1365 / 1372
页数:8
相关论文
共 22 条
  • [1] Abiman P, 2008, INT J ELECTROCHEM SC, V3, P104
  • [2] Multi-residue determination of veterinary drugs in milk by ultra-high-pressure liquid chromatography-tandem mass spectrometry
    Aguilera-Luiz, M. M.
    Martinez Vidal, Jose Luis
    Romero-Gonzalez, Roberto
    Garrido Frenich, Antonia
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1205 (1-2) : 10 - 16
  • [3] Evaluation of a Microbiological Multi-Residue System on the detection of antibacterial substances in ewe milk
    Althaus, Rafael
    Isabel Berruga, Maria
    Montero, Ana
    Roca, Marta
    Pilar Molina, Maria
    [J]. ANALYTICA CHIMICA ACTA, 2009, 632 (01) : 156 - 162
  • [4] Simultaneous determination of sulfonamides, tetracyclines and tiamulin in swine wastewater by solid-phase extraction and liquid chromatography-mass spectrometry
    Ben, Weiwei
    Qiang, Zhimin
    Adams, Craig
    Zhang, Heqing
    Chen, Liping
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (02) : 173 - 180
  • [5] Development of the electrochemical biosensor for organophosphate chemicals using CNT/ionic liquid bucky gel electrode
    Choi, Bong Gill
    Park, HoSeok
    Park, Tae Jung
    Kim, Dong Hyun
    Lee, Sang Yup
    Hong, Won Hi
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (03) : 672 - 675
  • [6] Sensitivity improvement of the oxidation of tetracycline at acetylene black electrode in the presence of sodium dodecyl sulfate
    Dang, XP
    Hu, CG
    Wei, YL
    Chen, WH
    Hu, SS
    [J]. ELECTROANALYSIS, 2004, 16 (23) : 1949 - 1955
  • [7] Ion-paired solid phase extraction as a sample preparation strategy for the-high-performance liquid chromatographic determination of oxytetracycline in the bryophyte Fontinalis antipyretica
    Delépée, R
    Pouliquen, H
    [J]. ANALYTICA CHIMICA ACTA, 2003, 475 (1-2) : 117 - 123
  • [8] Sensitive voltammetric response of methylparathion on single-walled carbon nanotube paste coated electrodes using ionic liquid as binder
    Fan, Shuangshuang
    Xiao, Fei
    Liu, Liqin
    Zhao, Faqiong
    Zeng, Baizhao
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 132 (01): : 34 - 39
  • [9] Molecular ordering of organic molten salts triggered by single-walled carbon nanotubes
    Fukushima, T
    Kosaka, A
    Ishimura, Y
    Yamamoto, T
    Takigawa, T
    Ishii, N
    Aida, T
    [J]. SCIENCE, 2003, 300 (5628) : 2072 - 2074
  • [10] Isolation of tetracyclines in milk using a solid-phase extracting column and water eluent
    Furusawa, N
    [J]. TALANTA, 2003, 59 (01) : 155 - 159