Magnetic resonance microscopy of spinal cord injury in mouse using a miniaturized implantable RF coil

被引:20
|
作者
Bilgen, Mehmet
机构
[1] Univ Kansas, Sch Med, Hoglund Brain Imaging Ctr, Kansas City, KS 66160 USA
[2] Univ Kansas, Sch Med, Dept Mol & Integrat Physiol, Kansas City, KS 66160 USA
关键词
magnetic resonance imaging; microscopy; inductive overcoupling; radio frequency coil; implantable coil; spinal cord;
D O I
10.1016/j.jneumeth.2006.06.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A magnetic resonance neuroimaging method is described for high-resolution imaging of spinal cord injury in live mouse. The method is based on a specially designed radio frequency coil system formed by a combination of an implantable coil and an external volume coil. The implantable coil is a 5 mm x 10 mm rectangular design with a 9.1 pF capacitor and 22 gauge copper wire and optimal for surgical implantation over the cervical or thoracic spine. The external volume coil is a standard birdcage resonator. The coils are inductively overcoupled for imaging the spinal cord at 9.4 T magnetic field strength. The inductive overcoupling provides flexibility in tuning the resonant frequency and matching the impedance of the implanted coil remotely using the tuning and matching capabilities of the volume coil. After describing the implementation of the imaging setup, in vivo data are gathered to demonstrate the imaging performance of the coil system and the feasibility of performing MR microscopy on injured mouse spinal cord. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:93 / 97
页数:5
相关论文
共 50 条
  • [1] In vivo magnetic resonance microscopy of rat spinal cord at 7 T using implantable RF coils
    Bilgen, M
    Elshafiey, I
    Narayana, PA
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1250 - 1253
  • [2] In Vivo Magnetic Resonance Imaging of Spinal Cord Injury in the Mouse
    Gonzalez-Lara, Laura E.
    Xu, Xiaoyun
    Hofstetrova, Klara
    Pniak, Anna
    Brown, Arthur
    Foster, Paula J.
    JOURNAL OF NEUROTRAUMA, 2009, 26 (05) : 753 - 762
  • [3] Magnetic resonance imaging of mouse spinal cord
    Bilgen, M
    Al-Hafez, B
    Berman, NEJ
    Festoff, BW
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) : 1226 - 1231
  • [4] An Implantable RF Solenoid for Magnetic Resonance Microscopy and Microspectroscopy
    Rivera, Debra S.
    Cohen, Mark S.
    Clark, W. Gilbert
    Chu, Allen C.
    Nunnally, Ray L.
    Smith, Jolinda
    Mills, Dixie
    Judy, Jack W.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (08) : 2118 - 2125
  • [5] Design of a superconducting volume coil for magnetic resonance microscopy of the mouse brain
    Nouls, John C.
    Izenson, Michael G.
    Greeley, Harold P.
    Johnson, G. Allan
    JOURNAL OF MAGNETIC RESONANCE, 2008, 191 (02) : 231 - 238
  • [6] Nuclear magnetic resonance microimaging of mouse spinal cord in vivo
    Bonny, JM
    Gaviria, M
    Donnat, JP
    Jean, B
    Privat, A
    Renou, JP
    NEUROBIOLOGY OF DISEASE, 2004, 15 (03) : 474 - 482
  • [7] In vivo 1H magnetic resonance imaging and spectroscopy of the rat spinal cord using an inductively-coupled chronically implanted RF coil
    Silver, X
    Ni, WX
    Mercer, EV
    Beck, BL
    Bossart, EL
    Inglis, B
    Mareci, TH
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1216 - 1222
  • [8] The Role of Magnetic Resonance Imaging and Computed Tomography in Spinal Cord Injury
    Hussain, Omar
    Kaushal, Mayank
    Agarwal, Nitin
    Kurpad, Shekar
    Shabani, Saman
    LIFE-BASEL, 2023, 13 (08):
  • [9] The Role of Magnetic Resonance Imaging in the Management of Acute Spinal Cord Injury
    Bozzo, Anthony
    Marcoux, Judith
    Radhakrishna, Mohan
    Pelletier, Julie
    Goulet, Benoit
    JOURNAL OF NEUROTRAUMA, 2011, 28 (08) : 1401 - 1411
  • [10] Clinical and magnetic resonance imaging correlation in acute spinal cord injury
    Ramon, S
    Dominguez, R
    Ramirez, L
    Paraira, M
    Olona, M
    Castello, T
    Fernandez, LG
    SPINAL CORD, 1997, 35 (10) : 664 - 673