Ocular Impression-Taking-Which Material Is Best?

被引:0
|
作者
Turner, Jennifer M. [1 ]
Purslow, Christine [1 ]
Murphy, Paul J. [1 ,2 ]
机构
[1] Cardiff Univ, Sch Optometry & Vis Sci, Cardiff, S Glam, Wales
[2] Univ Waterloo, Sch Optometry & Vis Sci, 200 Columbia Ave West, Waterloo, ON N2L 3G1, Canada
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2019年 / 45卷 / 01期
关键词
Ocular impression; Ocular surface; Ocular prosthetics; Materials; ELASTOMERIC IMPRESSION; LOCAL-ANESTHETICS; ACCURACY; REPEATABILITY;
D O I
10.1097/ICL.0000000000000496
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To assess the efficacy and effect on clinical signs of a polyvinylsiloxane (Tresident; Shutz Dental Group GmbH, Germany) compared with an irreversible hydrocolloid (Orthoprint; Zhermack SpA, Badia Polesine, Italy) for ocular impression-taking. Methods: Twenty subjects were recruited (13 female and 7 male), with mean age 31.164.6 years (SD) (range 25.8-39.7). Subjects attended for 2 sessions, each of 1-hr duration, on 2 separate days. Each session was scheduled at the same time on each day. At each visit, the subject underwent an ocular impression procedure, using either Tresident or Orthoprint, in random order and to one eye only. Investigator 2 was blind to this assignment. Two experienced practitioners conducted the study, investigator 1 performed the ocular impression procedures and investigator 2 observed and assessed the clinical signs: logMAR visual acuity, ocular surface staining, tear break-up time (TBUT), and ocular hyperemia. Results: Visual acuity was unaffected by either material; TBUT was marginally disrupted by both materials, but was not clinically significant according to published criteria; ocular redness increased with both materials; and corneal staining was significantly greater after Orthoprint impression. Less redness and clinically insignificant staining after impression-taking, with fewer clinical complications, was found after use of Tresident. Conclusions: Tresident offers a quicker, more effective, and clinically viable method of obtaining ocular impression topography compared with the traditional Orthoprint, and Orthoprint causes significantly more superficial punctuate staining of the corneal epithelium than Tresident.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 50 条
  • [1] Which final impression technique and material is best for complete and removable partial dentures?
    Al-Ansari A.
    Evidence-Based Dentistry, 2019, 20 (3) : 70 - 71
  • [2] What category of impression material is best for your practice?
    Christensen, GJ
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (07): : 1026 - 1028
  • [3] Taking a poke at the liver: which way is best?
    Shah, Neil D.
    Baron, Todd H.
    ENDOSCOPY INTERNATIONAL OPEN, 2019, 7 (01) : E72 - E73
  • [4] WHICH EMBOLIC MATERIAL IS BEST SUITED FOR WHICH EMBOLIZATION PROCEDURE
    PROBST, P
    CASTANEDAZUNIGA, WR
    GOMES, AS
    AMPLATZ, K
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1978, 129 (04): : 447 - 454
  • [5] Which is the best thin film piezoelectric material?
    Muralt, Paul
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [6] Impression cytology and ocular characteristics in ocular rosacea
    Koçak-Altintas, AG
    Kocak-Midillioglu, I
    Gül, U
    Bilezikci, B
    Isiksaçan, O
    Duman, S
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (04) : 351 - 359
  • [7] CAVITY PREPARATION AND IMPRESSION TAKING
    CUMMINS, RL
    JOURNAL OF PROSTHETIC DENTISTRY, 1966, 16 (02): : 376 - &
  • [8] Impression cytology of the ocular surface
    Singh, R
    Joseph, A
    Umapathy, T
    Tint, NL
    Dua, HS
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (12) : 1655 - 1659
  • [10] Ocular surface impression cytology
    McKelvie, P
    ADVANCES IN ANATOMIC PATHOLOGY, 2003, 10 (06) : 328 - 337