After a short introduction to the technique of high voltage circuit-breakers, their most popular drives and the ways to test them are presented. Afterwards the investigated test drive is introduced, as well as the design and realisation of the experiment. It is shown, that the drive is an efficient system, which possesses exceeding hydraulic edge conditions. Despite extreme climatic circumstances, the drive works reliably and maintenance-free during its whole lifecycle.
引用
收藏
页码:3980 / 3984
页数:5
相关论文
共 50 条
  • [21] ELECTRICAL ENDURANCE AND RELIABILITY OF CIRCUIT-BREAKERS - COMMON EXPERIENCE AND PRACTICE OF 2 UTILITIES
    PONS, A
    SABOT, A
    BABUSCI, G
    PIERRAT, L
    HEISING, CR
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (01) : 168 - 174
  • [22] Application of high current and current zero simulations of high-voltage circuit breakers
    Franck, C. M.
    Seeger, M.
    CONTRIBUTIONS TO PLASMA PHYSICS, 2006, 46 (10) : 787 - 797
  • [23] MEASUREMENT OF THE POST ARC CURRENT OF HV CIRCUIT-BREAKERS APPLICATION TO SHORT-CIRCUIT TESTS WITH ITRV
    GUILLOUX, C
    THERME, Y
    SCARPA, PG
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1148 - 1154
  • [24] Design objectives of new digital control and monitoring of high voltage circuit breakers
    Dupraz, JP
    Schiemann, A
    Montillet, GF
    2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 1088 - 1093
  • [25] Simulation by Neural Networks of Electric Arc Quenching in High Voltage Circuit Breakers
    Bryantsevich, Alexandro
    REVISTA DIGITAL LAMPSAKOS, 2010, (04): : 7 - 11
  • [26] EVALUATION OF THE EFFECT OF PRESSURIZED BUSHINGS ON SEISMIC QUALIFICATION OF SF6 CIRCUIT-BREAKERS
    OKUNO, M
    SETOYAMA, T
    MURASE, S
    HELLESTED, R
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (02) : 955 - 960
  • [27] Thermal behavior of automatic Thermal-Magnetic protection circuit-breakers: Experimental test
    Grasselli, Umberto
    Ruvio, Alessandro
    Tempra, Luca
    Felicetti, Carmelo
    2020 20TH IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2020 4TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2020,
  • [28] HYDRO-QUEBEC CONCERNS RELATED TO PERFORMANCES OF SF6 CIRCUIT-BREAKERS
    BEAUCHEMIN, R
    LATOUR, Y
    LANDRY, M
    RIFFON, P
    BEAUCHEMIN, R
    ALEXANDER, RW
    JEANJEAN, R
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1123 - 1129
  • [29] Monitoring and measurement of high-frequency oscillatory transient recovery voltage of circuit breakers
    Malekpour, Majid
    Pouramin, Alireza
    Malekpour, Amin
    Toan Phung
    Ambikairajah, Eliathamby
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2018, 12 (06) : 764 - 769
  • [30] Three-phase short circuit testing of high-voltage circuit breakers using synthetic circuits
    Dufournet, D
    Montillet, G
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (01) : 142 - 147