Combined sampler robot and high-performance liquid chromatography: a fully automated system for biological small-angle X-ray scattering experiments at the Synchrotron SOLEIL SWING beamline

被引:293
作者
David, G. [1 ]
Perez, J. [1 ]
机构
[1] Synchrotron SOLEIL, Orme Merisiers, F-91192 Gif Sur Yvette, France
关键词
SAXS;
D O I
10.1107/S0021889809029288
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Small-angle X-ray scattering for macromolecules in solution is now widely used in structural biology to complement high-resolution structure determination obtained by X-ray crystallography or NMR. In the context of third-generation synchrotron sources, this increasing interest leads to developments in sample environments and automation. The presence of an online purification system is justified by the need for sample monodispersity. A combined system including an auto-sampler robot and online high-performance liquid chromatography (HPLC) has been developed and optimized at the SWING beamline of Synchrotron SOLEIL (Gif-sur-Yvette, France). In the sample changer mode, a few microlitres of sample can be injected between two air bubbles and circulated at a controlled speed of typically 40 mu l min(-1). A maximum of 14 samples per hour could be measured in this mode by remote controlling the sample injections. In the HPLC mode, an initially polydisperse sample can be separated into each of its components before immediate data acquisition. The sample cell is thermostated, and offers a visualization control and online UV-Vis absorption monitoring.
引用
收藏
页码:892 / 900
页数:9
相关论文
共 13 条
  • [1] Improved signal-to-background ratio in small-angle X-ray scattering experiments with synchrotron radiation using an evacuated cell for solutions
    Dubuisson, JM
    Decamps, T
    Vachette, P
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1997, 30 : 49 - 54
  • [2] Protein interactions as seen by solution X-ray scattering prior to crystallogenesis
    Ducruix, A
    Guilloteau, JP
    RiesKautt, M
    Tardieu, A
    [J]. JOURNAL OF CRYSTAL GROWTH, 1996, 168 (1-4) : 28 - 39
  • [3] Guinier G Fournet A., 1955, SMALL ANGLE SCATTERI
  • [4] Small-angle scattering: a view on the properties, structures and structural changes of biological macromolecules in solution
    Koch, MHJ
    Vachette, P
    Svergun, DI
    [J]. QUARTERLY REVIEWS OF BIOPHYSICS, 2003, 36 (02) : 147 - 227
  • [5] PRIMUS:: a Windows PC-based system for small-angle scattering data analysis
    Konarev, PV
    Volkov, VV
    Sokolova, AV
    Koch, MHJ
    Svergun, DI
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2003, 36 : 1277 - 1282
  • [6] THE INFLUENCE OF TEMPERATURE ON LYSOZYME CRYSTALS - STRUCTURE AND DYNAMICS OF PROTEIN AND WATER
    KURINOV, IV
    HARRISON, RW
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1995, 51 : 98 - 109
  • [7] Liquid-chromatography-coupled SAXS for accurate sizing of aggregating proteins
    Mathew, E
    Mirza, A
    Menhart, N
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2004, 11 : 314 - 318
  • [8] Analysis of X-ray and neutron scattering from biomacromolecular solutions
    Petoukhov, Maxim V.
    Svergun, Dmitri I.
    [J]. CURRENT OPINION IN STRUCTURAL BIOLOGY, 2007, 17 (05) : 562 - 571
  • [9] X-ray solution scattering (SAXS) combined with crystallography and computation: defining accurate macromolecular structures, conformations and assemblies in solution
    Putnam, Christopher D.
    Hammel, Michal
    Hura, Greg L.
    Tainer, John A.
    [J]. QUARTERLY REVIEWS OF BIOPHYSICS, 2007, 40 (03) : 191 - 285
  • [10] Automated sample-changing robot for solution scattering experiments at the EMBL Hamburg SAXS station X33
    Round, A. R.
    Franke, D.
    Moritz, S.
    Huchler, R.
    Fritsche, M.
    Malthan, D.
    Klaering, R.
    Svergun, D. I.
    Roessle, M.
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2008, 41 : 913 - 917