FLEXOR POLLICIS LONGUS TENDON RUPTURES AFTER PALMAR PLATE FIXATION OF FRACTURES OF THE DISTAL RADIUS

被引:74
作者
Casaletto, J. A.
Machin, D.
Leung, R.
Brown, D. J.
机构
[1] Royal Liverpool Hosp, Liverpool Upper Limb Unit, Liverpool L7 8XP, Merseyside, England
[2] Broadgreen Univ Hosp, Liverpool Upper Limb Unit, Liverpool, Merseyside, England
关键词
flexor pollicis longus; rupture; distal radius fracture; palmar plating; PI PLATE; COMPLICATION; OSTEOSYNTHESIS; SYSTEM;
D O I
10.1177/1753193408100964
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Palmar plate fixation of distal radial fractures is becoming a standard treatment for this common injury. Ruptures of the extensor pollicis longus tendon have been reported in 8.6% of cases after this procedure. Although palmar plate fixation has also been associated with flexor pollicis longus (FPL) tendon problems, the majority of reported cases pre-date the use of newer anatomically pre-contoured locking plates. In this paper seven cases of FPL rupture are presented. This complication does not appear to be unique to one type of implant. The possible aetiologies for FPL ruptures are discussed and ways to reduce the incidence of this complication are suggested.
引用
收藏
页码:471 / 474
页数:4
相关论文
共 15 条
[1]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[2]  
[Anonymous], 1990, COMPREHENSIVE CLASSI
[3]   Limits of palmar locking-plate osteosynthesis of unstable distal radius fractures [J].
Arora, R. ;
Lutz, M. ;
Zimmermann, R. ;
Krappinger, D. ;
Gabl, M. ;
Pechlaner, S. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2007, 39 (01) :34-41
[4]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[5]   Rupture of the flexor tendons on an anterior plate for distal radial fracture: four cases and a review of the literature [J].
Cognet, JM ;
Dujardin, C ;
Popescu, A ;
Gouzou, S ;
Simon, R .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (05) :476-481
[6]   Flexor tendon injuries following locked volar plating of distal radius fractures [J].
Cross, Andrew W. ;
Schmidt, Christopher C. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02) :164-167
[7]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[8]   Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741
[9]   Ruptures of flexor tendons at the wrist as a complication of fracture of the distal radius [J].
Kato, N ;
Nemoto, K ;
Arino, H ;
Ichikawa, T ;
Fujikawa, K .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2002, 36 (04) :245-248
[10]   Loss of flexor pollicis longus function after plating of the radius - Report of six cases [J].
Keogh, P ;
Khan, H ;
Cooke, E ;
McCoy, G .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1997, 22B (03) :375-376