Feed rate control in robotic bone drilling process

被引:12
作者
Boiadjiev, Tony [1 ]
Boiadjiev, George [2 ]
Delchev, Kamen [2 ,3 ]
Chavdarov, Ivan [2 ]
Kastelov, Roumen [4 ]
机构
[1] Bulgarian Acad Sci, Inst Informat & Commun Technol, Sofia, Bulgaria
[2] Sofia Univ, Fac Math & Informat, 5 James Bourchier Blvd, Sofia 1164, Bulgaria
[3] Bulgarian Acad Sci, Inst Mech, Sofia, Bulgaria
[4] Minist Interior, Orthoped & Trauma Clin Ctr, Sofia, Bulgaria
关键词
Bone drilling; orthopaedic surgery; handheld-medical robot; feed rate control; thrust force feedback;
D O I
10.1177/0954411920975890
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The bone drilling process is characterised by various parameters, the most important of which are the feed rate (mm/s) and the drill speed (rpm). They highly reflect the final effects and results of the drilling process, such as mechanical and thermal damages of bone tissue and hole quality. During manual drilling, these parameters are controlled by the surgeon based on his practical skills. But automatic drilling can assure an optimal result of the manipulation where such parameters are under control. During bicortical automatic bone drilling such a process consists of several stages: searching the contact with the first cortex, cortex drilling and automatic stop; searching the contact with the second cortex, cortex drilling and automatic stop; drill bit extraction. This work presents a way to control the feed rate during different stages of the bone drilling process (an original feed rate control algorithm) using the orthopaedic drilling robot (ODRO). The feed rate control is based on a proposed algorithm created and realised by specific software. During bicortical bone drilling process the feed rate takes various values in any stage in the range 0.5-6 mm/s. These values depend on drill bit position and real time force sensor data. The novelty of this work is the synthesis of an original feed rate control algorithm to solve the main problems of bone drilling in orthopaedic surgery - minimisation the drilling time (the heat generation); eliminating of the drill bit slip at the first (near) cortex and the drill bit bending at the second (far) cortex; minimising the risk of micro cracks which causes Traumatic Osteonecrosis; improving hole quality of the drilled holes; eliminating of the drill bit slip and the drill bit bending at the second cortex; minimising the value of the second cortex drill bit penetration by bicortical bone drilling.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 31 条
  • [1] Plunging When Drilling: Effect of Using Blunt Drill Bits
    Alajmo, Giuseppe
    Schlegel, Urs
    Gueorguiev, Boyko
    Matthys, Romano
    Gautier, Emanuel
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (08) : 482 - 487
  • [2] Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone
    Alam, K.
    Mitrofanov, A. V.
    Silberschmidt, V. V.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2011, 33 (02) : 234 - 239
  • [3] Experimental measurements of temperatures in ultrasonically assisted drilling of cortical bone
    Alam, Khurshid
    Hassan, Edris
    Bahadur, Issam
    [J]. BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2015, 29 (04) : 753 - 757
  • [4] Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws
    Allan, W
    Williams, ED
    Kerawala, CJ
    [J]. BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2005, 43 (04) : 314 - 319
  • [5] Thermal osteonecrosis and bone drilling parameters revisited
    Augustin, Goran
    Davila, Slavko
    Mihoci, Kristijan
    Udiljak, Toma
    Vedrina, Denis Stjepan
    Antabak, Anko
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (01) : 71 - 77
  • [6] Cortical bone drilling and thermal osteonecrosis
    Augustin, Goran
    Zigman, Tomislav
    Davila, Slavko
    Udilljak, Toma
    Staroveski, Tomislav
    Brezak, Danko
    Babic, Slaven
    [J]. CLINICAL BIOMECHANICS, 2012, 27 (04) : 313 - 325
  • [7] The effects of drilling force on cortical temperatures and their duration: an in vitro study
    Bachus, KN
    Rondina, MT
    Hutchinson, DT
    [J]. MEDICAL ENGINEERING & PHYSICS, 2000, 22 (10) : 685 - 691
  • [8] Bertollo N., 2011, Biomechanics in Applications, P53
  • [9] Boiadjiev George, 2014, Applied Mechanics and Materials, V664, P419, DOI 10.4028/www.scientific.net/AMM.664.419
  • [10] Boiadjiev G., 2013, INT J PURE APPL MATH, V88, P577