Development and comparison of direct immersion solid phase micro extraction Arrow-GC-MS for the determination of selected pesticides in water

被引:23
作者
Khademi, Seyed Mohammad Seyed [1 ]
Salemi, Amir [2 ]
Jochmann, Maik [1 ]
Joksimoski, Sasho [1 ]
Telgheder, Ursula [1 ,3 ]
机构
[1] Univ Duisburg Essen, Dept Instrumental Analyt Chem IAC, Univ Str 5, D-45141 Essen, Germany
[2] Shahid Beheshti Univ, Environm Sci Res Inst, Dept Environm Technol, POB 19839-63113, Tehran, Iran
[3] IWW, Moritz Str 26, D-45476 Mulheim, Germany
关键词
Central composite design; GC?MS; Pesticide; SPME arrow; Water;
D O I
10.1016/j.microc.2021.106006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pesticides are compounds which can affect human, environmental and aquatic system health. Therefore, the detection and determination of these compounds at trace level concentrations is of great importance. In this study selected pesticides out of four classes were investigated as target analytes: Dichlorovos as an insecticide, terbutryn as herbicide, cybutryne from the group of biocides and quinoxyfen as an example of fungicides. A direct immersion solid phase micro extraction (SPME) Arrow-GC?MS method was developed and validated for fully automated microextraction of the target compounds from aqueous samples. In this regard, the most important experimental parameters of the extraction: Extraction time, extraction temperature, pH, ionic strength of the sample and the Arrow type, were studied and optimized. In addition, the developed method was compared with the conventional SPME, regarding sensitivity, relative recovery and precision. The limit of detection values of SPME Arrow were between 0.68 and 544 ng L-1 for dichlorvos and quioxyfen, respectively, and significantly less than similar values obtained from conventional SPME (4.63 and 4400 ng L-1 for the same compounds). For all investigated pesticides, recovery rates ranged between 90 and 116% for the Arrow as well as 85 and 107% for the classical SPME fiber. Relative standard deviations (RSD %) were 4.3?7.8 and 3.5?11.8 for the Arrow and classic SPME, respectively. Also, coefficient of determination (R2) range was within the range of 0.993?0.999 for SPME Arrow and 0.990?0.996 for classic SPME.
引用
收藏
页数:6
相关论文
共 37 条
[1]  
[Anonymous], 2016, LC GC N AM, P18
[2]  
[Anonymous], 2007, Polychlorinated Biphenyls (PCBs) by gas chromatography, P1
[3]  
[Anonymous], 2008, Progress on drinking water and sanitation: special focus on sanitation, P1
[4]   Solid-phase microextraction for quantitative analysis of organophosphorus pesticides in environmental water samples [J].
Beltran, J ;
Lopez, FJ ;
Cepria, O ;
Hernandez, F .
JOURNAL OF CHROMATOGRAPHY A, 1998, 808 (1-2) :257-263
[5]   Concentrations of the antifouling compound Irgarol 1051 and of organotins in water and sediments of German North and Baltic Sea marinas [J].
Biselli, S ;
Bester, K ;
Hühnerfuss, H ;
Fent, K .
MARINE POLLUTION BULLETIN, 2000, 40 (03) :233-243
[6]   LC-MS analysis of antifouling agent Irgarol 1051 and its decyclopropylated degradation product in seawater from marinas in Hong Kong [J].
Cai, Zongwei ;
Fun, Yun ;
Ma, Wai-Tang ;
Lam, Michael Hon-Wah ;
Tsui, James .
TALANTA, 2006, 70 (01) :91-96
[7]   Contamination of Caribbean coastal waters by the antifouling herbicide Irgarol 1051 [J].
Carbery, Kelly ;
Owen, Richard ;
Frickers, Trish ;
Otero, Ernesto ;
Readman, James .
MARINE POLLUTION BULLETIN, 2006, 52 (06) :635-644
[8]   Study of the presence of pesticides in surface waters in the Ebro river basin (Spain) [J].
Claver, Ana ;
Ormad, Pena ;
Rodriguez, Luis ;
Ovelleiro, Jose Luis .
CHEMOSPHERE, 2006, 64 (09) :1437-1443
[9]   Determination of organochlorine pesticides in water samples by dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry [J].
Cortada, Carol ;
Vidal, Lorena ;
Pastor, Raul ;
Santiago, Noemi ;
Canals, Antonio .
ANALYTICA CHIMICA ACTA, 2009, 649 (02) :218-221
[10]   Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry [J].
Diaz, Laura ;
Llorca-Porcel, Julio ;
Valor, Ignacio .
ANALYTICA CHIMICA ACTA, 2008, 624 (01) :90-96