Quantification of susceptibility artifacts produced on high-field magnetic resonance images by various biomaterials used for neurosurgical implants - Technical note

被引:60
作者
Matsuura, H
Inoue, T
Konno, H
Sasaki, M
Ogasawara, K
Ogawa, A
机构
[1] Iwate Med Univ, Dept Neurosurg, Morioka, Iwate 0208505, Japan
[2] Iwate Med Univ, Dept Radiol, Morioka, Iwate 0208505, Japan
关键词
neurosurgical implant; magnetic resonance imaging; susceptibility artifact;
D O I
10.3171/jns.2002.97.6.1472
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Although various biomaterials such as ceramics or titanium alloy are widely used in neurosurgery, the susceptibility artifacts that appear around these materials cause problems when a magnetic resonance (MR) imager is used to assess lesions after surgery. The purpose of the present study was to quantify the susceptibility artifacts produced by various biomaterials used for neurosurgical implants. Using a 3-tesla MR imaging unit, we obtained MR images of various biomaterials, including six types of ceramics, a cobalt-based alloy (Elgiloy), pure titanium, a titanium alloy, and stainless steel. All implants shared a uniform size and shape. In each image, a linear region of interest was defined across the center of the biomaterial in the transverse direction, and the diameter of the susceptibility artifact was calculated. The ceramics produced a considerably smaller artifact diameter than those produced by other biomaterials. Among the types of ceramics, zirconia was found to produce the smallest artifact diameter. Among the remaining biomaterials, the diameters of the artifacts decreased in order from that associated with stainless steel to those associated with cobalt-based alloys, pure titanium, and titanium alloy. Little difference was observed between the artifact diameters associated with pure titanium and titanium alloy. Ceramics are the most suitable biomaterials for minimizing artifacts in high-field MR imaging.
引用
收藏
页码:1472 / 1475
页数:4
相关论文
共 21 条
[1]  
BATZDORF U, 1991, SPINE, V16, P123, DOI 10.1097/00007632-199116020-00004
[2]   CLINICAL NMR IMAGING OF THE BRAIN - 140 CASES [J].
BYDDER, GM ;
STEINER, RE ;
YOUNG, IR ;
HALL, AS ;
THOMAS, DJ ;
MARSHALL, J ;
PALLIS, CA ;
LEGG, NJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (02) :215-236
[3]   NICKEL-DOPED AGAROSE-GEL PHANTOMS IN MR IMAGING [J].
CHRISTOFFERSSON, JO ;
OLSSON, LE ;
SJOBERG, S .
ACTA RADIOLOGICA, 1991, 32 (05) :426-431
[4]   VISUALIZATION OF CEREBRAL AND VASCULAR ABNORMALITIES BY NMR IMAGING - THE EFFECTS OF IMAGING PARAMETERS ON CONTRAST [J].
CROOKS, LE ;
MILLS, CM ;
DAVIS, PL ;
BRANTZAWADZKI, M ;
HOENNINGER, J ;
ARAKAWA, M ;
WATTS, J ;
KAUFMAN, L .
RADIOLOGY, 1982, 144 (04) :843-852
[5]   CLINICAL-EFFICIENCY OF NUCLEAR MAGNETIC-RESONANCE IMAGING [J].
CROOKS, LE ;
ORTENDAHL, DA ;
KAUFMAN, L ;
HOENNINGER, J ;
ARAKAWA, M ;
WATTS, J ;
CANNON, CR ;
BRANTZAWADZKI, M ;
DAVIS, PL ;
MARGULIS, AR .
RADIOLOGY, 1983, 146 (01) :123-128
[6]   EFFECT OF FIELD-STRENGTH ON SUSCEPTIBILITY ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING [J].
FARAHANI, K ;
SINHA, U ;
SINHA, S ;
CHIU, LCL ;
LUFKIN, RB .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1990, 14 (06) :409-413
[7]  
Frahm C, 1996, CARDIOVASC INTER RAD, V19, P335
[8]  
Fujisawa A., 1996, BIOCERAMICS, V9, P495
[9]   Artefact on MRA following aneurysm clipping:: an in vitro study and prospective comparison with conventional angiography [J].
Grieve, JP ;
Stacey, R ;
Moore, E ;
Kitchen, ND ;
Jäger, HR .
NEURORADIOLOGY, 1999, 41 (09) :680-686
[10]   RECONSTRUCTION OF THE SELLAR FLOOR DURING TRANS-SPHENOIDAL OPERATIONS USING ALUMINA CERAMIC [J].
KOBAYASHI, S ;
SUGITA, K ;
MATSUO, K ;
INOUE, T .
SURGICAL NEUROLOGY, 1981, 15 (03) :196-197