Fluorescent nitrogen and sulfur co-doped carbon dots from casein and their applications for sensitive detection of Hg2+ and biothiols and cellular imaging

被引:103
作者
Xu, Shouming [1 ]
Liu, Yang [1 ,2 ]
Yang, Hong [3 ]
Zhao, Kang [1 ]
Li, Jianguo [1 ]
Deng, Anping [1 ]
机构
[1] Soochow Univ, Coll Chem Chem Engn & Mat Sci, Key Lab Hlth Chem & Mol Diag Suzhou, Suzhou 215123, Peoples R China
[2] Nantong Univ, Sch Publ Hlth, 9 Seyuan Rd, Nantong 226019, Peoples R China
[3] Soochow Univ, Coll Pharm Sci, Suzhou 215123, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon dots (CDs); Nitrogen and sulfur co-doped carbon dots (NSCDs); Hg2+; Biothiols; Detection; Cellular imaging; POT GREEN SYNTHESIS; GRAPHENE QUANTUM DOTS; LABEL-FREE DETECTION; ONE-STEP SYNTHESIS; SELECTIVE DETECTION; RECOVERED FLUORESCENCE; FACILE SYNTHESIS; NANODOTS; MERCURY; PROBE;
D O I
10.1016/j.aca.2017.01.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fluorescent nitrogen and sulfur co-doped carbon dots (NSCDs) were synthesized by a one-step pyrolysis strategy using casein as carbon, nitrogen and sulfur sources, and characterized by UVevis spectrum, fluorescent spectrum, X-ray photoelectron spectroscopy (XPS) and FT-IR, etc. The synthesized NSCDs displayed a blue emission under ultraviolet illumination with a quantum yield of 31.8%, and a good aqueous solubility, photostability and biocompatibility. It was found that the fluorescence intensity of NSCDs could be selectively quenched by Hg2+, so NSCDs was used as an effective probe for the detection of Hg2+. The linear range and the limit of detection (LOD) of the fluorescent sensor based on NSCDs for the detection of Hg2+ were 0.01-0.25 mu M and 6.5 mu M, respectively. Spiked water samples were detected by the sensor with the recovery of 95.4-106.3% and relative standard deviation (RSD) of 3.6-8.6%. It was also observed that the quenched NSCDs-Hg2+ system could be restored by the addition of biothiols such as L-cysteine (Lcy), homocysteine (Hcy) and glutathione (GSH), thus NSCDs-Hg2+ system was employed as a fluorescent sensor for the detection of biothiols. The linear range and LOD of the NSCDs-Hg2+ system were 1-10 mM and 23.6 nM for Lcy, 0.2-2.5 mM and 12.3 nM for Hcy, and 0.1-2.0 mM and 16.8 nM for GSH, respectively. The NSCDs-Hg2+ system was applied for the detection of biothiols in serum samples with satisfied results. In addition, the study in vitro imaging HeLa cells revealed that the synthesized NSCDs could be used as effective fluorescent probes in cellular imaging without noticeable cytotoxicity. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:150 / 160
页数:11
相关论文
共 64 条
  • [1] [Anonymous], 2010, ANGEW CHEM-GER EDIT, DOI DOI 10.1002/ANGE.201000982
  • [2] Recent Trends in Macro-, Micro-, and Nanomaterial-Based Tools and Strategies for Heavy-Metal Detection
    Aragay, Gemma
    Pons, Josefina
    Merkoci, Arben
    [J]. CHEMICAL REVIEWS, 2011, 111 (05) : 3433 - 3458
  • [3] Development of a Rhodamine-Rhodanine-Based Fluorescent Mercury Sensor and Its Use to Monitor Real-Time Uptake and Distribution of Inorganic Mercury in Live Zebrafish Larvae
    Bera, Kallol
    Das, Anand Kant
    Nag, Moupnya
    Basak, Soumen
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (05) : 2740 - 2746
  • [4] Carbon dots for multiphoton bioimaging
    Cao, Li
    Wang, Xin
    Meziani, Mohammed J.
    Lu, Fushen
    Wang, Haifang
    Luo, Pengju G.
    Lin, Yi
    Harruff, Barbara A.
    Veca, L. Monica
    Murray, Davoy
    Xie, Su-Yuan
    Sun, Ya-Ping
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (37) : 11318 - +
  • [5] Luminescent CdS quantum dots as selective ion probes
    Chen, YF
    Rosenzweig, Z
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (19) : 5132 - 5138
  • [6] Aptamer-capped nanocrystal quantum dots: A new method for label-free protein detection
    Choi, Jong Hyun
    Chen, Kok Hao
    Strano, Michael S.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (49) : 15584 - 15585
  • [7] Nuclear factor κB activity determines the sensitivity of kidney epithelial cells to apoptosis:: Implications for mercury-induced renal failure
    Dieguez-Acuña, FJ
    Polk, WW
    Ellis, ME
    Simmonds, PL
    Kushleika, JV
    Woods, JS
    [J]. TOXICOLOGICAL SCIENCES, 2004, 82 (01) : 114 - 123
  • [8] Carbon-Based Dots Co-doped with Nitrogen and Sulfur for High Quantum Yield and Excitation-Independent Emission
    Dong, Yongqiang
    Pang, Hongchang
    Yang, Hong Bin
    Guo, Chunxian
    Shao, Jingwei
    Chi, Yuwu
    Li, Chang Ming
    Yu, Ting
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2013, 52 (30) : 7800 - 7804
  • [9] Carbon Quantum Dots and Applications in Photocatalytic Energy Conversion
    Fernando, K. A. Shiral
    Sahu, Sushant
    Liu, Yamin
    Lewis, William K.
    Guliants, Elena A.
    Jafariyan, Anairhossein
    Wang, Ping
    Bunker, Christopher E.
    Sun, Ya-Ping
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (16) : 8363 - 8376
  • [10] Foda M. F., 2011, ACS APPL MATER INTER, V6, P2011