The effect of gradually graded shear stress on the morphological integrity of a huvec-seeded compliant small-diameter vascular graft

被引:95
作者
Inoguchi, Hiroyuki
Tanaka, Takashi
Maehara, Yoshihiko
Matsuda, Takehisa
机构
[1] Kyushu Univ, Grad Sch Med, Div Biomed Engn, Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Univ, Grad Sch Med, Div Surg & Sci, Higashi Ku, Fukuoka 8128582, Japan
[3] Yasuhisa Koki Bio Mech Co Ltd, Ohta Ku, Tokyo 1460092, Japan
关键词
graded shear stress; endothelial cell; small-diameter vascular graft;
D O I
10.1016/j.biomaterials.2006.09.020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The premature endothelialization of tissue-engineered grafts had often induced cellular detachment at an early period of implantation in arterial circulation, resulting in occlusion at an early period of implantation. This study was aimed to determine whether gradually increased shear stress applied ex vivo improves cell retention and tissue morphological integrity including cell shape and alignment, actin fiber alignment and expression of vascular endothelial (VE) cadherin. Tissue-engineered grafts used for this study were human umbilical vein endothelial cell (HUVEC)-seeded compliant small-diameter grafts made of POLY(L-lactide-co-epsilon-caprolactone) fiber meshes fabricated by electrospinning. The shear stresses applied to grafts, generated using a custom-designed mock circulatory apparatus, were 3.2, 8.7 and 19.6 dyn/cm(2). The grafts completely monolayered prior to shear stress exposure exhibited a polygonal cobblestone morphology with randomly distributed actin fibers and VE cadherin at the continuous peripheral region of adjacent cells. The 24-h-loading of high shear stresses (8.7 and 19.6dyn/cm(2)) equivalent to those of the arterial circulatory system resulted in severe cellular damage resulting in the complete loss of cells. However, a gradually increased graded exposure from a low (3.2dyn/cm(2)) to a high shear stress (19.6dyn/cm(2)) resulted in a markedly reduced cell detachment, a highly elongated cell shape, and orientation or alignment of both cells and actin fibers, which were parallel to the direction of flow. Although VE-cadherin expression was not detected yet, a higher degree of tissue integrity was achieved, which may greatly improve the performance particularly at an early period of implantation. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:486 / 495
页数:10
相关论文
共 25 条
[1]   SHEAR-STRESS INHIBITS ADHESION OF CULTURED MOUSE ENDOTHELIAL-CELLS TO LYMPHOCYTES BY DOWN-REGULATING VCAM-1 EXPRESSION [J].
ANDO, J ;
TSUBOI, H ;
KORENAGA, R ;
TAKADA, Y ;
TOYAMASORIMACHI, N ;
MIYASAKA, M ;
KAMIYA, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 267 (03) :C679-C687
[2]   MECHANICAL-STRESS MECHANISMS AND THE CELL - AN ENDOTHELIAL PARADIGM [J].
DAVIES, PF ;
TRIPATHI, SC .
CIRCULATION RESEARCH, 1993, 72 (02) :239-245
[3]   FLUID-FLOW STIMULATES TISSUE PLASMINOGEN-ACTIVATOR SECRETION BY CULTURED HUMAN-ENDOTHELIAL CELLS [J].
DIAMOND, SL ;
ESKIN, SG ;
MCINTIRE, LV .
SCIENCE, 1989, 243 (4897) :1483-1485
[4]   Arterial replacement with compliant hierarchic hybrid vascular graft: Biomechanical adaptation and failure [J].
He, HB ;
Matsuda, T .
TISSUE ENGINEERING, 2002, 8 (02) :213-224
[5]   Canine endothelial progenitor cell-lined hybrid vascular graft with nonthrombogenic potential [J].
He, HB ;
Shirota, T ;
Yasui, H ;
Matsuda, T .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (02) :455-464
[6]  
He HB, 2001, CELL TRANSPLANT, V11, P75
[7]   Mechanical responses of a compliant electrospun poly(L-lactide-co-ε-caprolactone) small-diameter vascular graft [J].
Inoguchi, H ;
Kwon, IK ;
Inoue, E ;
Takamizawa, K ;
Maehara, Y ;
Matsuda, T .
BIOMATERIALS, 2006, 27 (08) :1470-1478
[8]  
KAMIYA A, 1984, B MATH BIOL, V46, P127, DOI 10.1016/S0092-8240(84)80038-5
[9]   Mesoscopic spatial designs of nano- and microfiber meshes for tissue-engineering matrix and scaffold based on newly devised multilayering and mixing electrospinning techniques [J].
Kidoaki, S ;
Kwon, IK ;
Matsuda, T .
BIOMATERIALS, 2005, 26 (01) :37-46
[10]   Structural features and mechanical properties of in situ-bonded meshes of segmented polyurethane electrospun from mixed solvents [J].
Kidoaki, S ;
Kwon, K ;
Matsuda, T .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 76B (01) :219-229