A photographic technique for assessing the viewing-angle performance of liquid-crystal displays

被引:3
作者
Fetterly, Kenneth A.
Samei, Ehsan
机构
[1] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
[2] Duke Univ, Dept Radiol, Duke Adv Imaging Labs, Durham, NC USA
[3] Duke Univ, Dept Phys, Duke Adv Imaging Labs, Durham, NC USA
[4] Duke Univ, Dept Phys Med, Duke Adv Imaging Labs, Durham, NC USA
[5] Duke Univ, Dept Biomed Engn, Duke Adv Imaging Labs, Durham, NC USA
关键词
liquid-crystal display; viewing angle;
D O I
10.1889/1.2372420
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Liquid-crystal displays (LCDs) have notable variation in luminance and perceived contrast as a function of the angle from which they are viewed. Though this is an important performance issue for LCDs, most evaluation techniques for assessing this variation have been limited to laboratory settings. This study demonstrates the use of a photographic technique for such an evaluation. The technique is based on an actively cooled charge-coupled-device (CCD) detector in combination with a macro lens covering a circular angular range (theta) of +/-42.5 degrees. The camera was used to evaluate the luminance and perceived contrast properties of an LCD. Uniform field images corresponding to 17 equally spaced gray-scale values in the digital driving level (DDL) range of the display system were acquired. The 12-bit gray-scale digital images produced by the camera were converted to luminance units (cd/m(2)) via the measured luminance vs. DDL response function of the camera. The changes in perceived contrast as a function of viewing angle were derived from the Barten model of the gray-scale response of the human-visual system using the methods proposed by the AAPM TG18 Report. The results of this photographic technique were compared to measurements acquired from a similar display using a Fourier-optics-based luminance meter. The results of the two methods generally agreed to within 5%. The photographic methods used were found to be accurate and robust for in-field assessment of the angular response of LCDs over the FOV of the camera.
引用
收藏
页码:867 / 872
页数:6
相关论文
共 8 条
[1]   Goniometric and conoscopic measurements of angular display contrast for one-, three-, five-, and nine-million-pixel medical liquid crystal displays [J].
Badano, A ;
Fifadara, DH .
MEDICAL PHYSICS, 2004, 31 (12) :3452-3460
[2]  
Barten P. G. J., 1999, CONTRAST SENSITIVITY
[3]  
BARTEN PGJ, 1992, P SOC PHOTO-OPT INS, V1666, P57, DOI 10.1117/12.135956
[4]  
KRUPINSKI EA, 2004 RSNA ANN M
[5]  
*NEMA, 2001, DIG IM COMM MED D 14
[6]   Viewing angle performance of medical liquid crystal displays [J].
Samei, E ;
Wright, SL .
MEDICAL PHYSICS, 2006, 33 (03) :645-654
[7]   Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report [J].
Samei, E ;
Badano, A ;
Chakraborty, D ;
Compton, K ;
Cornelius, C ;
Corrigan, K ;
Flynn, MJ ;
Hemminger, B ;
Hangiandreou, N ;
Johnson, J ;
Moxley-Stevens, DM ;
Pavlicek, W ;
Roehrig, H ;
Rutz, L ;
Samei, E ;
Shepard, J ;
Uzenoff, RA ;
Wang, JH ;
Willis, CE .
MEDICAL PHYSICS, 2005, 32 (04) :1205-1225
[8]  
*VESA DISPL METR C, 2001, FLAT PAN DISPL MEAS