Implantation techniques and chronic lead parameters of biventricular pacing dual-chamber defibrillators

被引:66
作者
Daoud, EG [1 ]
Kalbfleisch, SJ [1 ]
Hummel, JD [1 ]
Weiss, R [1 ]
Augustini, RS [1 ]
Duff, SB [1 ]
Polsinelli, G [1 ]
Castor, J [1 ]
Meta, T [1 ]
机构
[1] Riverside Methodist Hosp, MidWest Res Fdn, Columbus, OH USA
关键词
heartfailure; pacemaker; defibrillator; resynchronization; left ventricle; lead;
D O I
10.1046/j.1540-8167.2002.00964.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The aim of this study is to describe implantation techniques and lead performance for biventricular pacing, dual-chamber implantable cardioverter defibrillators (ICDs). Methods and Results: A dual-chamber ICD with biventricular pacing was implanted in 87 patients with congestive heart failure (ejection fraction: 0.21 +/- 0.09), prolonged QRS duration (161 +/- 22 msec), and an indication for ICD therapy. Left ventricular pacing was achieved with a thoracotomy approach (n = 21) or a nonthoracotomy approach (n = 66). With a thoracotomy, biventricular devices were implanted successfully in all patients. During follow-up (17 +/- 11 months), 9 patients died (43%), 2 underwent transplantation, and 2 required left ventricular lead revision. At last follow-up, biventricular sensing and capture threshold were 11 +/- 5 mV and 1.5 +/- 0.8 V, respectively. For nonthoracotomy procedures, two types of coronary sinus (CS) leads were implanted: an over-the-wire lead (n = 45) and a shaped lead (n = 21). The rate of successful implantation (overall: 89%) (over-the-wire 93% vs shaped 81%; P = 0.1) and durations for CS lead placement (66 +/- 50 vs 58 +/- 34 min, P = 0.6) and the procedure (133 +/- 58 vs 129 +/- 33 min, P = 0.8) were not different between the two CS leads. During follow-up (11 9 months), 9 patients died (14%), and the shaped CS lead dislodged in 3 patients (3 shaped vs 0 over-the-wire, P = 0.01). At last follow-up, biventricular sensing and capture threshold were 10 +/- 4 mV and 1.8 +/- 0.7 V, respectively, and there was no difference between over-the-wire and shaped leads. By multivariate analysis, mortality was associated with absence of spironolactone therapy but not procedural features. Conclusion: Nonthoracotomy CS lead implantation is feasible, with a success rate of about 90% and few adverse events. For the remaining 10%, a thoracotomy approach can be completed safely in these ill patients without increased risk for death.
引用
收藏
页码:964 / 970
页数:7
相关论文
共 24 条
  • [1] Abraham WT, 2002, NEW ENGL J MED, V346, P1902
  • [2] Achtelik M, 2000, PACE, V23, P1741
  • [3] High failure rate for an epicardial implantable cardioverter-defibrillator lead: Implications for long-term follow-up of patients with an implantable cardioverter-defibrillator
    Brady, PA
    Friedman, PA
    Trusty, JM
    Grice, S
    Hammill, SC
    Stanton, MS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) : 616 - 622
  • [4] Echocardiographic evidence of a hemodynamic and clinical improvement in patients paced for heart failure
    Breithardt, OA
    Stellbrink, C
    Franke, A
    Auricchio, A
    Huvelle, E
    Sack, S
    Bakker, P
    Hanrath, P
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (9A) : 133K - 137K
  • [5] Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay.
    Cazeau, S
    Leclercq, C
    Lavergne, T
    Walker, S
    Varma, C
    Linde, C
    Garrigue, S
    Kappenberger, L
    Haywood, GA
    Santini, M
    Bailleul, C
    Daubert, JC
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (12) : 873 - 880
  • [6] Initial clinical experience with ambulatory use of an implantable atrial defibrillator for conversion of atrial fibrillation
    Daoud, EG
    Timmermans, C
    Fellows, C
    Hoyt, R
    Lemery, R
    Dawson, K
    Ayers, GM
    [J]. CIRCULATION, 2000, 102 (12) : 1407 - 1413
  • [7] INCIDENCE, PRESENTATION, DIAGNOSIS, AND MANAGEMENT OF MALFUNCTIONING IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR RATE-SENSING LEADS
    DAOUD, EG
    KIRSH, MM
    BOLLING, SF
    STRICKBERGER, SA
    MORADY, F
    KOU, WH
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (05) : 892 - 895
  • [8] FUNCTIONAL ABNORMALITIES IN ISOLATED LEFT-BUNDLE BRANCH-BLOCK - THE EFFECT OF INTERVENTRICULAR ASYNCHRONY
    GRINES, CL
    BASHORE, TM
    BOUDOULAS, H
    OLSON, S
    SHAFER, P
    WOOLEY, CF
    [J]. CIRCULATION, 1989, 79 (04) : 845 - 853
  • [9] Biventricular pacing decreases sympathetic activity compared with right ventricular pacing in patients with depressed ejection fraction
    Hamdan, MH
    Zagrodzky, JD
    Joglar, JA
    Sheehan, CJ
    Ramaswamy, K
    Erdner, JF
    Page, RL
    Smith, ML
    [J]. CIRCULATION, 2000, 102 (09) : 1027 - 1032
  • [10] Left heart pacing - Experience with several types of coronary vein leads
    Hansky, B
    Vogt, J
    Gueldner, H
    Lamp, B
    Tenderich, G
    Krater, L
    Heintze, J
    Minami, K
    Horstkotte, D
    Koerfer, R
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2002, 6 (01) : 71 - 75