VOLUMETRIC ARC INTENSITY-MODULATED THERAPY FOR SPINE BODY RADIOTHERAPY: COMPARISON WITH STATIC INTENSITY-MODULATED TREATMENT

被引:92
|
作者
Wu, Q. Jackie [1 ]
Yoo, Sua [1 ]
Kirkpatrick, John P. [1 ]
Thongphiew, Danthai [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Dept Radiat Oncol, Durham, NC 27710 USA
关键词
Intensity-modulated arc therapy; Intensity-modulated radiation therapy; Spine; Stereotactic body radiotherapy; RADIATION-THERAPY; STEREOTACTIC RADIOSURGERY; CORD; TOLERANCE; DELIVERY; IMRT;
D O I
10.1016/j.ijrobp.2009.05.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This clinical study evaluates the feasibility of using volumetric arc-modulated treatment (VMAT) for spine stereotactic body radiotherapy (SBRT) to achieve highly conformal dose distributions that spare adjacent organs at risk (OAR) with reduced treatment time. Methods and Materials: Ten spine SBRT patients were studied retrospectively. The intensity-modulated radiotherapy (IMRT) and VMAT plans were generated using either one or two arcs. Planning target volume (PTV) dose coverage, OAR dose sparing, and normal tissue integral dose were measured and compared. Differences in treatment delivery were also analyzed. Results: The PTV DVHs were comparable between VMAT and IMRT plans in the shoulder (D-99%-D-90%), slope (D-90%-D-10%), and tail (D-10%-D-1%) regions. Only VMAT(2arc) had a better conformity index than IMRT (1.09 vs. 1.15,p = 0.007). For cord sparing, IMRT was the best, and VMAT(1arc) was the worst. Use of IMRT achieved greater than 10% more D-1% sparing for six of 10 cases and 7% to 15% more D-10% sparing over the VAMT(1arc). The differences between IMRT and VAMT(2arc) were smaller and statistically nonsignificant at all dose levels. The differences were also small and statistically nonsignificant for other OAR sparing. The mean monitor units (MUs) were 8711, 7730, and 6317 for IMRT, VMAT(1arc) and VMAT(2arc) plans, respectively, with a 26% reduction from IMRT to VMAT(2arc). The mean treatment time was 15.86,8.56, and 7.88 min for IMRT, VMAT(1arc) and VMAT(2arc) The difference in integral dose was statistically nonsignificant. Conclusions: Although VMAT provided comparable PTV coverage for spine SBRT, 1arc showed significantly worse spinal cord sparing compared with IMRT, whereas 2are was comparable to IMRT. Treatment efficiency is substantially improved with the VMAT. (C) 2009 Elsevier Inc.
引用
收藏
页码:1596 / 1604
页数:9
相关论文
共 50 条
  • [1] Volumetric Modulated Arc Therapy for Spine Body Radiotherapy: Comparison with Static Intensity Modulated Treatment
    Wu, Q.
    Yoo, S.
    Kirkpatrick, J.
    McMahon, R.
    Thongphiew, D.
    Yin, F.
    MEDICAL PHYSICS, 2009, 36 (06) : 2655 - +
  • [2] Treatment Efficiency of Volumetric Modulated Arc Therapy in Comparison With Intensity-Modulated Radiotherapy in the Treatment of Prostate Cancer
    Hall, William A.
    Fox, Timothy H.
    Jiang, Xiaojun
    Prabhu, Roshan S.
    Rossi, Peter J.
    Godette, Karen
    Jani, Ashesh B.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (02) : 128 - 134
  • [3] Volumetric modulated arc therapy in differentiated thyroid cancer: a treatment planning comparison with intensity-modulated radiotherapy
    Chan, Wing Lok
    Ng, Sherry C. Y.
    Law, Martin W. M.
    Lee, Victor H. F.
    Wan, K. Y.
    Leung, T. W.
    JOURNAL OF RADIATION ONCOLOGY, 2015, 4 (04) : 417 - 422
  • [4] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [5] VOLUMETRIC-MODULATED ARC THERAPY FOR STEREOTACTIC BODY RADIOTHERAPY OF LUNG TUMORS: A COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY TECHNIQUES
    Holt, Andrea
    van Vliet-Vroegindeweij, Corine
    Mans, Anton
    Belderbos, Jose S.
    Damen, Eugene M. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1560 - 1567
  • [6] Volumetric intensity-modulated Arc (RapidArc) therapy for primary hepatocellular carcinoma: comparison with intensity-modulated radiotherapy and 3-D conformal radiotherapy
    Yu-Cheng Kuo
    Ying-Ming Chiu
    Wen-Pin Shih
    Hsiao-Wei Yu
    Chia-Wen Chen
    Pei-Fong Wong
    Wei-Chan Lin
    Jeng-Jong Hwang
    Radiation Oncology, 6
  • [7] Volumetric intensity-modulated Arc (RapidArc) therapy for primary hepatocellular carcinoma: comparison with intensity-modulated radiotherapy and 3-D conformal radiotherapy
    Kuo, Yu-Cheng
    Chiu, Ying-Ming
    Shih, Wen-Pin
    Yu, Hsiao-Wei
    Chen, Chia-Wen
    Wong, Pei-Fong
    Lin, Wei-Chan
    Hwang, Jeng-Jong
    RADIATION ONCOLOGY, 2011, 6
  • [8] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Arc Therapy for Rectal Cancer
    Oskeroglu Kaplan, Sedenay
    Akboru, Halil
    Sarali, Yunus
    Altin, Suleyman
    Unsal, Mustafa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (02): : 59 - 65
  • [9] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for liver stereotactic ablative body radiotherapy
    Thibault, Isabelle
    Wronski, Matt
    Korol, Renee
    Chu, William
    Helou, Joelle
    Erler, Darby
    Chung, Hans T.
    JOURNAL OF RADIATION ONCOLOGY, 2016, 5 (01) : 63 - 69
  • [10] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy for the Treatment of Multiple Intracranial Metastases
    Liu, X.
    Yin, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 2912 - 2912