VOLUMETRIC ARC INTENSITY-MODULATED THERAPY FOR SPINE BODY RADIOTHERAPY: COMPARISON WITH STATIC INTENSITY-MODULATED TREATMENT

被引:92
作者
Wu, Q. Jackie [1 ]
Yoo, Sua [1 ]
Kirkpatrick, John P. [1 ]
Thongphiew, Danthai [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Dept Radiat Oncol, Durham, NC 27710 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2009年 / 75卷 / 05期
关键词
Intensity-modulated arc therapy; Intensity-modulated radiation therapy; Spine; Stereotactic body radiotherapy; RADIATION-THERAPY; STEREOTACTIC RADIOSURGERY; CORD; TOLERANCE; DELIVERY; IMRT;
D O I
10.1016/j.ijrobp.2009.05.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This clinical study evaluates the feasibility of using volumetric arc-modulated treatment (VMAT) for spine stereotactic body radiotherapy (SBRT) to achieve highly conformal dose distributions that spare adjacent organs at risk (OAR) with reduced treatment time. Methods and Materials: Ten spine SBRT patients were studied retrospectively. The intensity-modulated radiotherapy (IMRT) and VMAT plans were generated using either one or two arcs. Planning target volume (PTV) dose coverage, OAR dose sparing, and normal tissue integral dose were measured and compared. Differences in treatment delivery were also analyzed. Results: The PTV DVHs were comparable between VMAT and IMRT plans in the shoulder (D-99%-D-90%), slope (D-90%-D-10%), and tail (D-10%-D-1%) regions. Only VMAT(2arc) had a better conformity index than IMRT (1.09 vs. 1.15,p = 0.007). For cord sparing, IMRT was the best, and VMAT(1arc) was the worst. Use of IMRT achieved greater than 10% more D-1% sparing for six of 10 cases and 7% to 15% more D-10% sparing over the VAMT(1arc). The differences between IMRT and VAMT(2arc) were smaller and statistically nonsignificant at all dose levels. The differences were also small and statistically nonsignificant for other OAR sparing. The mean monitor units (MUs) were 8711, 7730, and 6317 for IMRT, VMAT(1arc) and VMAT(2arc) plans, respectively, with a 26% reduction from IMRT to VMAT(2arc). The mean treatment time was 15.86,8.56, and 7.88 min for IMRT, VMAT(1arc) and VMAT(2arc) The difference in integral dose was statistically nonsignificant. Conclusions: Although VMAT provided comparable PTV coverage for spine SBRT, 1arc showed significantly worse spinal cord sparing compared with IMRT, whereas 2are was comparable to IMRT. Treatment efficiency is substantially improved with the VMAT. (C) 2009 Elsevier Inc.
引用
收藏
页码:1596 / 1604
页数:9
相关论文
共 30 条
  • [1] Radiation for primary spine tumors
    Bilsky, Mark H.
    Gerszten, Peter
    Laufer, Ilya
    Yamada, Yoshiya
    [J]. NEUROSURGERY CLINICS OF NORTH AMERICA, 2008, 19 (01) : 119 - +
  • [2] Comparison of plan quality provided by intensity-modulated arc therapy and helical tomotherapy
    Cao, Daliang
    Holmes, Timothy W.
    Afghan, Muhammad K. N.
    Shepard, David M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 240 - 250
  • [3] Phase I clinical evaluation of near-simultaneous computed tomographic image-guided stereotactic body radiotherapy for spinal metastases
    Chang, EL
    Shiu, AS
    Lii, MF
    Rhines, LD
    Mendel, E
    Mahajan, A
    Weinberg, JS
    Mathews, LA
    Brown, BW
    Maor, MH
    Cox, JD
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (05): : 1288 - 1294
  • [4] Phase I/II study of stereotactic body radiotherapy for spinal metastasis and its pattern of failure
    Chang, Eric L.
    Shiu, Almon S.
    Mendel, Ehud
    Mathews, Leni A.
    Mahajan, Anita
    Allen, Pamela K.
    Weinberg, Jeffrey S.
    Brown, Barry W.
    Wang, Xin Shelly
    Woo, Shiao Y.
    Cleeland, Charles
    Maor, Moshe H.
    Rhines, Laurence D.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (02) : 151 - 160
  • [5] Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods
    Chui, CS
    Chan, MF
    Yorke, E
    Spirou, S
    Ling, CC
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2441 - 2449
  • [6] Methodological issues in radiation dose-volume outcome analyses: Summary of a joint AAPM/NIH workshop
    Deasy, JO
    Niemierko, A
    Herbert, D
    Yan, D
    Jackson, A
    Ten Haken, RK
    Langer, M
    Sapareto, S
    [J]. MEDICAL PHYSICS, 2002, 29 (09) : 2109 - 2127
  • [7] Inverse planning for intensity-modulated arc therapy using direct aperture optimization
    Earl, MA
    Shepard, DM
    Naqvi, S
    Li, XA
    Yu, CX
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) : 1075 - 1089
  • [8] Gerszten PC, 2004, NEUROSURGERY, V55, P89, DOI 10.1227/01.NEU.0000126873.00845.A7
  • [9] Leaf-sequencing for intensity-modulated arc therapy using graph algorithms
    Luan, Shuang
    Wang, Chao
    Cao, Daliang
    Chen, Danny Z.
    Shepard, David M.
    Yu, Cedric X.
    [J]. MEDICAL PHYSICS, 2008, 35 (01) : 61 - 69
  • [10] Spinal cord tolerance to high-dose fractionated 3D conformal proton-photon irradiation as evaluated by equivalent uniform dose and dose volume histogram analysis
    Marucci, L
    Niemierko, A
    Liebsch, NJ
    Aboubaker, F
    Liu, MCC
    Munzenrider, JE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02): : 551 - 555