Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience

被引:32
|
作者
Kostopoulou, Anna [1 ]
Karyofillis, Panagiotis [1 ]
Livanis, Efthimios [1 ]
Thomopoulou, Sofia [1 ]
Stefopoulos, Christos [1 ]
Doudoumis, Konstantinos [1 ]
Theodorakis, Georgios [1 ]
Voudris, Vassilios [1 ]
机构
[1] Onassis Cardiac Surg Ctr, Dept Cardiol, Athens, Greece
来源
EUROPACE | 2016年 / 18卷 / 01期
关键词
Transcatheter aortic valve implantation; Atrioventricular block; Bundle branch block; Pacemaker; Electrophysiology test; BUNDLE-BRANCH BLOCK; DEGREE ATRIOVENTRICULAR-BLOCK; CONDUCTION ABNORMALITIES; PACEMAKER REQUIREMENT; STENOSIS; SYSTEM; QRS;
D O I
10.1093/europace/euv137
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The most frequent conduction complications with transcatheter aortic valve implantation (TAVI) are complete atrioventricular (AV) block and new bundle branch block (BB). The purpose of this study was to assess clinical, electrocardiographic, and electrophysiological predictors of conduction abnormalities in patients (pts) undergoing TAVI with the CoreValve prosthesis. The secondary end points were the long-term rhythm follow-up and the recovery of conduction. Forty-five consecutive pts with severe aortic stenosis, New York Heart Association II/III, and normal or slightly impaired left ventricular function who underwent CoreValve transcatheter implantation were randomized 2:1 to electrocardiographic and electrocardiographic plus electrophysiological evaluations. Pacemakers were implanted in pts with complete AV block. Follow-up was performed at 1, 6, 12, and 24 months. Conduction was affected in the total group of pts undergoing TAVI. The PR lengthened compared with the baseline but did not exceed the normal cut-off of 200 ms, and the QRS widened, basically due to new left bundle branch blocks (LBBBs). Within 1 month of follow-up, 10 pts (22%) developed complete AV block (9 peri-procedurally-20%) and 15 pts (33%) developed a new bundle BB, with LBBBs being the most common (14-31%). In the 30 pts who underwent an electrophysiological study, analysis showed that prolonged HV intervals were prognostic for pacemaker implantation. Follow-up in the total study group revealed that only 4 of the 10 (9%) initial implantations remained completely pacemaker dependent. Conduction was affected in all pts undergoing TAVI, but serious complications that required permanent pacing generally occurred in pts with pre-existing conduction abnormalities.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 50 条
  • [41] Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation
    Lopez-Aguilera, Jose
    Segura Saint-Gerons, Jose Maria
    Mazuelos Bellido, Francisco
    Suarez de Lezo, Javier
    Ojeda Pineda, Soledad
    Pan Alvarez-Ossorio, Manuel
    Romero Moreno, Miguel Angel
    Pavlovic, Djordje
    Espejo Perez, Simona
    Suarez de Lezo, Jose
    REVISTA ESPANOLA DE CARDIOLOGIA, 2016, 69 (01): : 28 - 36
  • [42] Incidence and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with a balloon-expandable biosprosthesis in patients with bicuspid aortic valves
    Suygun, Hakan
    Kasapkara, Haci Ahmet
    Guney, Murat Can
    Polat, Melike
    Bozkurt, Engin
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2024, 20 (03): : 311 - 318
  • [43] Predictors for permanent pacemaker implantation following transcatheter aortic valve implantation: trends over the past decade
    Eliav, Rotem
    Elitzur, Yair
    Planer, David
    Beeri, Ronen
    Gilon, Dan
    Shuvy, Mony
    Luria, David
    Danenberg, Haim
    Perlman, Gidon Y.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (02) : 299 - 307
  • [44] ;Electrocardiographic and Imaging Predictors for Permanent Pacemaker (PPM) Implantation Following Transcatheter Aortic Valve Replacement (TAVR)
    Routh, Jared M.
    Joseph, Lee
    Marthaler, Brodie R.
    Bhave, Prashant
    CIRCULATION, 2015, 132
  • [45] Timing of Conduction Abnormalities Leading to Permanent Pacemaker Insertion After Transcatheter Aortic Valve Implantation-A Single-Centre Review
    Ozier, Daniel
    Zivkovic, Nevena
    Elbaz-Greener, Gabby
    Singh, Sheldon M.
    Wijeysundera, Harindra C.
    CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (12) : 1660 - 1667
  • [46] Predictors of high-degree conduction disturbances and pacemaker implantation after transcatheter aortic valve replacement: Prognostic role of the electrophysiological study
    Ferreira, Thomas
    Da Costa, Antoine
    Cerisier, Alexis
    Vidal, Nicolas
    Guichard, Jean Baptiste
    Romeyer, Cecile
    Barthelemy, Jean Claude
    Isaaz, Karl
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (05): : 843 - 855
  • [47] Right subclavian approach in transcatheter aortic valve implantation using the CoreValve prosthesis
    Tousek, Petr
    Kocka, Viktor
    Bednar, Frantisek
    Dvoracek, Miroslav
    Vlcek, Libor
    Bulvas, Miroslav
    Linkova, Hana
    Sulzenko, Jakub
    Widimsky, Petr
    COR ET VASA, 2012, 54 (05) : E326 - E328
  • [48] Correlates on MSCT of Paravalvular Aortic Regurgitation After Transcatheter Aortic Valve Implantation Using the Medtronic CoreValve Prosthesis
    Schultz, Carl J.
    Tzikas, Apostolos
    Moelker, Adriaan
    Rossi, Alexia
    Nuis, Rutger-Jan
    Geleijnse, Marcel M.
    van Mieghem, Nicolas
    Krestin, Gabriel P.
    de Feyter, Pim
    Serruys, Patrick W.
    de Jaegere, Peter P.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 78 (03) : 446 - 455
  • [49] Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3
    Mauri, Victor
    Reimann, Andreas
    Stern, Daniel
    Scherner, Maximilian
    Kuhn, Elmar
    Rudolph, Volker
    Rosenkranz, Stephan
    Eghbalzadeh, Kaveh
    Friedrichs, Kai
    Wahlers, Thorsten
    Baldus, Stephan
    Madershahian, Navid
    Rudolph, Tanja K.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (21) : 2200 - 2209
  • [50] The impact of transcatheter aortic valve implantation on left ventricular performance and wall thickness - single-centre experience
    Stoklosa, Patrycjusz
    Szymanski, Piotr
    Dabrowski, Maciej
    Zakrzewski, Dariusz
    Michalek, Piotr
    Orlowska-Baranowska, Ewa
    E-Hassan, Kamal
    Chmielak, Zbigniew
    Witkowski, Adam
    Hryniewiecki, Tomasz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2015, 11 (01): : 37 - 43