Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience

被引:32
|
作者
Kostopoulou, Anna [1 ]
Karyofillis, Panagiotis [1 ]
Livanis, Efthimios [1 ]
Thomopoulou, Sofia [1 ]
Stefopoulos, Christos [1 ]
Doudoumis, Konstantinos [1 ]
Theodorakis, Georgios [1 ]
Voudris, Vassilios [1 ]
机构
[1] Onassis Cardiac Surg Ctr, Dept Cardiol, Athens, Greece
来源
EUROPACE | 2016年 / 18卷 / 01期
关键词
Transcatheter aortic valve implantation; Atrioventricular block; Bundle branch block; Pacemaker; Electrophysiology test; BUNDLE-BRANCH BLOCK; DEGREE ATRIOVENTRICULAR-BLOCK; CONDUCTION ABNORMALITIES; PACEMAKER REQUIREMENT; STENOSIS; SYSTEM; QRS;
D O I
10.1093/europace/euv137
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The most frequent conduction complications with transcatheter aortic valve implantation (TAVI) are complete atrioventricular (AV) block and new bundle branch block (BB). The purpose of this study was to assess clinical, electrocardiographic, and electrophysiological predictors of conduction abnormalities in patients (pts) undergoing TAVI with the CoreValve prosthesis. The secondary end points were the long-term rhythm follow-up and the recovery of conduction. Forty-five consecutive pts with severe aortic stenosis, New York Heart Association II/III, and normal or slightly impaired left ventricular function who underwent CoreValve transcatheter implantation were randomized 2:1 to electrocardiographic and electrocardiographic plus electrophysiological evaluations. Pacemakers were implanted in pts with complete AV block. Follow-up was performed at 1, 6, 12, and 24 months. Conduction was affected in the total group of pts undergoing TAVI. The PR lengthened compared with the baseline but did not exceed the normal cut-off of 200 ms, and the QRS widened, basically due to new left bundle branch blocks (LBBBs). Within 1 month of follow-up, 10 pts (22%) developed complete AV block (9 peri-procedurally-20%) and 15 pts (33%) developed a new bundle BB, with LBBBs being the most common (14-31%). In the 30 pts who underwent an electrophysiological study, analysis showed that prolonged HV intervals were prognostic for pacemaker implantation. Follow-up in the total study group revealed that only 4 of the 10 (9%) initial implantations remained completely pacemaker dependent. Conduction was affected in all pts undergoing TAVI, but serious complications that required permanent pacing generally occurred in pts with pre-existing conduction abnormalities.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 50 条
  • [21] Incidence and clinical outcome of prosthesis-patient mismatch after transcatheter aortic valve implantation with the CoreValve prosthesis
    Munoz-Garcia, Antonio J.
    Munoz-Garcia, Manuel
    Carrasco-Chinchilla, Fernando
    Molina-Mora, Maria J.
    Rodriguez-Bailon, Isabel
    Dominguez-Franco, Antonio J.
    Jimenez-Navarro, Manuel F.
    Alonso-Briales, Juan H.
    Gomez-Doblas, Juan J.
    Hernandez-Garcia, Jose M.
    de Teresa-Galvan, Eduardo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (03) : 1074 - 1076
  • [22] Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis
    Baan, Jan, Jr.
    Yong, Ze Yie
    Koch, Karel T.
    Henriques, Jose P. S.
    Bouma, Berto J.
    Vis, Marije M.
    Cocchieri, Riccardo
    Piek, Jan J.
    de Mol, Bas A. J. M.
    AMERICAN HEART JOURNAL, 2010, 159 (03) : 497 - 503
  • [23] Conduction recovery and avoidance of permanent pacing after transcatheter aortic valve implantation
    Marzahn, Corinne
    Koban, Cornel
    Seifert, Martin
    Isotani, Akihiro
    Neuss, Michael
    Hoeschermann, Frank
    Butter, Christian
    JOURNAL OF CARDIOLOGY, 2018, 71 (1-2) : 101 - 108
  • [24] Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation
    Hoydahl, Martin Petter
    Kjonas, Didrik
    Rosner, Assami
    Antonsen, Bendik Trones
    Forsdahl, Signe Helene
    Busund, Rolf
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2025, 59 (01)
  • [25] Atrioventricular Conduction Disturbance Characterization in Transcatheter Aortic Valve Implantation With the CoreValve Prosthesis
    Rubin, Jose M.
    Avanzas, Pablo
    del Valle, Raquel
    Renilla, Alfredo
    Rios, Enrique
    Calvo, David
    Lozano, Inigo
    Anguera, Ignasi
    Diaz-Molina, Beatriz
    Cequier, Angel
    Moris de la Tassa, Cesar
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) : 280 - 286
  • [26] Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation
    Fujita, Buntaro
    Kuetting, Maximilian
    Seiffert, Moritz
    Scholtz, Smita
    Egron, Sandrine
    Prashovikj, Emir
    Boergermann, Jochen
    Schaefer, Timm
    Scholtz, Werner
    Preuss, Rainer
    Gummert, Jan
    Steinseifer, Ulrich
    Ensminger, Stephan M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (12) : 1385 - 1393
  • [27] 5-Year Outcomes After Transcatheter Aortic Valve Implantation With CoreValve Prosthesis
    Barbanti, Marco
    Petronio, Anna Sonia
    Ettori, Federica
    Latib, Azeem
    Bedogni, Francesco
    De Marco, Federico
    Poli, Arnaldo
    Boschetti, Carla
    De Carlo, Marco
    Fiorina, Claudia
    Colombo, Antonio
    Brambilla, Nedy
    Bruschi, Giuseppe
    Martina, Paola
    Pandolfi, Claudia
    Giannini, Cristina
    Curello, Salvatore
    Sgroi, Carmelo
    Gulino, Simona
    Patane, Martina
    Ohno, Yohei
    Tamburino, Claudia
    Attizzani, Guilherme F.
    Imme, Sebastiano
    Gentili, Alessandra
    Tamburino, Corrado
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (08) : 1084 - 1091
  • [28] Transcatheter aortic valve implantation with a mechanically expandable prosthesis: a learning experience for permanent pacemaker implantation rate reduction
    Ortak, Jasmin
    D'Ancona, Giuseppe
    Ince, Hueseyin
    Agma, Hueseyin U.
    Safak, Erdal
    Oener, Alper
    Kische, Stephan
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2018, 23
  • [29] Transcatheter aortic valve implantation versus sutureless aortic valve replacement: a single-centre cost analysis
    De Paepe, Jarne
    Lamberigts, Marie
    Meuris, Bart
    Jacobs, Steven
    Adriaenssens, Tom
    Dubois, Christophe
    Verbrugghe, Peter
    ACTA CARDIOLOGICA, 2024, 79 (01) : 30 - 40
  • [30] Permanent Pacemaker Insertion After CoreValve Transcatheter Aortic Valve Implantation Incidence and Contributing Factors (the UK CoreValve Collaborative)
    Khawaja, M. Z.
    Rajani, R.
    Cook, A.
    Khavandi, A.
    Moynagh, A.
    Chowdhary, S.
    Spence, M. S.
    Brown, S.
    Khan, S. Q.
    Walker, N.
    Trivedi, U.
    Hutchinson, N.
    De Belder, A. J.
    Moat, N.
    Blackman, D. J.
    Levy, R. D.
    Manoharan, G.
    Roberts, D.
    Khogali, S. S.
    Crean, P.
    Brecker, S. J.
    Baumbach, A.
    Mullen, M.
    Laborde, J. -C.
    Hildick-Smith, D.
    CIRCULATION, 2011, 123 (09) : 951 - U47