An optical fiber-based monitoring system to study the seepage flow below the landside toe of a river levee

被引:28
作者
Cola, Simonetta [1 ]
Girardi, Veronica [1 ]
Bersan, Silvia [2 ]
Simonini, Paolo [1 ]
Schenato, Luca [3 ]
De Polo, Fabio [4 ]
机构
[1] Univ Padua, Dept Civil Environm & Architectural Engn, Via Ognissanti 39, Padua, Italy
[2] CRUX Engn, Phoenixstr 28c, Delft, Netherlands
[3] CNR, Res Inst Geohydrol Protect, Corso Stati Uniti 4, Padua, Italy
[4] Mt Water Author, Via Cesare Battisti 23, Bolzano, Italy
关键词
Levee; Seepage; Piping; Fiber optic sensor; Monitoring;
D O I
10.1007/s13349-021-00475-y
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The development of innovative monitoring systems to mitigate the risk associated to river levee failure is a recent challenge involving synergic effort of public institutions, specialized companies and academics. The present study examines a 350 m stretch of Adige river levees, located in the Province of Bolzano (Italy) close to the village of Salorno, interested in the recent past by moderate piping phenomena and subjected to subsequent interventions for seepage control (cut-off diaphragm wall). As is customary, the levee body and its foundation soil were investigated through geophysical and geotechnical surveys. The arising results provided a multi-dimensional characterization of the levee and the nearby soil water-meadows likely to be affected by preferential paths for piping. The detection of those paths entailed the joined use of piezometers and distributed optical fiber sensing (DFOS) system, the latter installed in a shallow trench on the landside. In the last days of October 2018, Northeastern Italy was hit by a tremendous storm and the Adige river was subjected to a relevant double flooding event. This exceptional circumstance, entirely recorded by the monitoring system, gives the chance to provide insight into the seepage process undermining the levee stability.
引用
收藏
页码:691 / 705
页数:15
相关论文
共 40 条
[1]  
Albalat C, 1995, EDFD400723GC953018 E
[2]  
Amabile A, 2020, CAN GEOTECH J
[3]  
Bersan S, 2015, THESIS U PADOVA
[4]   Large-Scale Testing of Distributed Temperature Sensing for Early Detection of Piping [J].
Bersan, Silvia ;
Koelewijn, Andre R. ;
Putti, Mario ;
Simonini, Paolo .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2019, 145 (09)
[5]   Effectiveness of distributed temperature measurements for early detection of piping in river embankments [J].
Bersan, Silvia ;
Koelewijn, Andre R. ;
Simonini, Paolo .
HYDROLOGY AND EARTH SYSTEM SCIENCES, 2018, 22 (02) :1491-1508
[6]   Application of a high resolution distributed temperature sensor in a physical model reproducing subsurface water flow [J].
Bersan, Silvia ;
Schenato, Luca ;
Rajendran, Aneesh ;
Palmieri, Luca ;
Cola, Simonetta ;
Pasuto, Alessandro ;
Simonini, Paolo .
MEASUREMENT, 2017, 98 :321-324
[7]  
Bonelli S, 2013, CIV ENG GEOMECH SER, P1, DOI 10.1002/9781118577165
[8]  
BOSSI G., 2018, INTERNAL EROSION EAR, P234
[9]   Combined geophysical surveys for the characterization of a reconstructed river embankment [J].
Busato, Laura ;
Boaga, Jacopo ;
Peruzzo, Luca ;
Himi, Mahjoub ;
Cola, Simonetta ;
Bersan, Silvia ;
Cassiani, Giorgio .
ENGINEERING GEOLOGY, 2016, 211 :74-84
[10]  
Cejka F, 2018, WATER STUDIES, P171, DOI 10.2495/EI-V1-N3-267-278