A comparative study of Cu-Ni Alloy using LIBS, LA-TOF, EDX, and XRF

被引:84
作者
Ahmed, N. [1 ,2 ]
Ahmed, R. [1 ]
Rafiqe, M. [2 ]
Baig, M. A. [1 ]
机构
[1] Natl Ctr Phys, Quaid I Azam Univ Campus, Islamabad 45320, Pakistan
[2] Univ Azad Jammu & Kashmir, Dept Phys, Muzaffarabad, Azad Kashmir, Pakistan
关键词
CF-LIBS; CuNi alloy; Electron density; LA-TOFMS; LIBS; Plasma temperature; Quantitative analysis; LASER-INDUCED BREAKDOWN; QUANTITATIVE ELEMENTAL ANALYSIS; INDUCED PLASMA; SPECTROSCOPY; SPECTROMETRY; EMISSION;
D O I
10.1017/S0263034616000732
中图分类号
O59 [应用物理学];
学科分类号
摘要
LASER induced breakdown spectroscopy (LIBS) has been used for the quantitative analysis of Cu-Ni alloy of known composition (75% Cu, 25% Ni) using the one line calibration free-LIBS (OLCF-LIBS), self-calibration-LIBS (SC-LIBS), calibration free LIBS (CF-LIBS), time of flight-mass spectroscopy (TOF-MS), energy dispersive X-ray spectroscopy (EDX) and X-ray fluorescence spectroscopy (XRF). For the LIBS-based studies, the plasma was generated by focusing the beam of a Q-switched Nd:YAG laser (532 nm, pulse energy about 200 mJ, 5 ns pulse duration) while the sample was placed in air at an atmospheric pressure. Plasma temperature about (9500 +/- 300) K was calculated by the Boltzmann plot method using the neutral lines of Cu and Ni whereas the electron number density was calculated (2.0 +/- 0.5) x 10(16) cm(-3) from the Stark broadening of an isolated Cu line as well as using the relative intensities of the neutral and singly ionized optically thin lines in the Saha-Boltzmann equation. The elemental compositions determined by different LIBS methods and standard techniques are; OLCF-LIBS (69% Cu and 31% Ni), SC-LIBS (72% Cu and 28% Ni), CF-LIBS (74% Cu and 26% Ni), TOF (74% Cu and 26% Ni), EDX (75% Cu and 24.5% Ni), XRF (73% Cu and 24.7% Ni), and LA-TOF (74% Cu and 26% Ni). It is demonstrated that the CF-LIBS method gives compositions comparable with that determined by LA-TOF, EDX, or XRF, which is also in agreement with the certified reported composition.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 40 条
[1]   Application of calibration-free laser-induced breakdown spectroscopy to radially resolved spectra from a copper-based alloy laser-induced plasma [J].
Aguilera, J. A. ;
Aragon, C. ;
Cristoforetti, G. ;
Tognoni, E. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (07) :685-689
[2]   Effects of laser wavelengths and pulse energy ratio on the emission enhancement in dual pulse LIBS [J].
Ahmed, Rizwan ;
Iqbal, Javed ;
Baig, M. Aslam .
LASER PHYSICS LETTERS, 2015, 12 (06)
[3]   A comparative study of enhanced emission in double pulse laser induced breakdown spectroscopy [J].
Ahmed, Rizwan ;
Baig, M. A. .
OPTICS AND LASER TECHNOLOGY, 2015, 65 :113-118
[4]   A comparative study of single and double pulse laser induced breakdown spectroscopy [J].
Ahmed, Rizwan ;
Baig, M. Aslam .
JOURNAL OF APPLIED PHYSICS, 2009, 106 (03)
[5]  
Andrzej W. M., 2006, LASER INDUCED BREAKD
[6]  
[Anonymous], 2006, Handbook of Laser-Induced Breakdown Spectroscopy
[7]  
[Anonymous], AT SPECTR DAT
[8]  
Babina EM, 2003, PUB ASTRO OBS BELGR, P163
[9]   Spatial diagnostics of the laser induced lithium fluoride plasma [J].
Baig, M. A. ;
Qamar, Aisha ;
Fareed, M. A. ;
Anwar-ul-Haq, M. ;
Ali, Raheel .
PHYSICS OF PLASMAS, 2012, 19 (06)
[10]   Effects of experimental parameters in quantitative analysis of steel alloy by laser-induced breakdown spectroscopy [J].
Bassiotis, I ;
Diamantopoulou, A ;
Giannoudakos, A ;
Roubani-Kalantzopoulou, F ;
Kompitsas, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (06) :671-683