Orbital implants: potential new directions

被引:14
作者
Hicks, Celia R.
Morrison, David
Lou, Xia
Crawford, Geoffrey J. [1 ]
Gadjatsy, Adam
Constable, Ian J.
机构
[1] Univ Western Australia, Ctr Ophthalmol & Visual Sci, Nedlands, WA 6009, Australia
[2] Univ Western Australia, Lions Eye Inst, Dept Biomat & Polymer Res, Nedlands, WA 6009, Australia
[3] Curtin Univ Technol, Nanochem Res Inst, Bentley, WA 6102, Australia
[4] Curtin Univ Technol, Dept Chem Engn, Bentley, WA 6102, Australia
关键词
biocolonization; enucleation; orbital implant;
D O I
10.1586/17434440.3.6.805
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article reviews orbital implants used to replace an eye after enucleation or evisceration. Advantages of implant placement are described, with discussion of implant and wrap material, and design features that affect clinical outcomes. Implants may be porous or nonporous, pegged for linkage with a cosmetic shell or unpegged, and may be wrapped with a covering material or tissue or unwrapped. Device shape, volume and material qualities affect tissue tolerance and the risk of exposure or extrusion. Limitations of currently available devices are discussed, with factors affecting surgeon and patient choice. Ideally, a device should be easy to insert, avoid the need for wrapping or adjunctive tissues, be light, biointegratable, comfortable after implantation and provide satisfactory orbital volume replacement, movement and cosmesis without requiring further surgery or pegging. This review briefly discusses developments in implant design and aspects of design that affect function, but is not a detailed clinical review; rather, it aims to stimulate thought on optimal design and discusses recent developments. Novel technology in the form of a prototype device with a soft, biointegratable anterior surface is described as an example of newer approaches.
引用
收藏
页码:805 / 815
页数:11
相关论文
共 63 条
  • [1] Anophthalmic socket and orbital implants - Role of CT and MR imaging
    Ainbinder, DJ
    Haik, BG
    Mazzoli, RA
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 1998, 36 (06) : 1133 - +
  • [2] The quasi-integrated porous polyethylene orbital implant
    Anderson, RL
    Yen, MT
    Lucci, LM
    Caruso, RT
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 18 (01) : 50 - 55
  • [3] The porous polyethylene (Medpor) spherical orbital implant - A retrospective study of 136 cases
    Blaydon, SM
    Shepler, TR
    Neuhaus, RW
    White, WL
    Shore, JW
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 19 (05) : 364 - 371
  • [4] INTERPENETRATING POLYMER NETWORK (IPN) AS A PERMANENT JOINT BETWEEN THE ELEMENTS OF A NEW-TYPE OF ARTIFICIAL CORNEA
    CHIRILA, TV
    VIJAYASEKARAN, S
    HORNE, R
    CHEN, YC
    DALTON, PD
    CONSTABLE, IJ
    CRAWFORD, GJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (06): : 745 - 753
  • [5] Intraorbital implants after enucleation and their complications - A 10-year review
    Christmas, NJ
    Gordon, CD
    Murray, TG
    Tse, D
    Johnson, T
    Garonzik, S
    O'Brien, JM
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (09) : 1199 - 1203
  • [6] Chuah CT, 2004, ANN ACAD MED SINGAP, V33, P477
  • [7] Enucleation: Past, present, and future
    Custer, PL
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 16 (05) : 316 - 321
  • [8] Orbital implants in enucleation surgery - A report by the American Academy of Ophthalmology
    Custer, PL
    Kennedy, RH
    Woog, JJ
    Kaltreider, SA
    Meyer, DR
    [J]. OPHTHALMOLOGY, 2003, 110 (10) : 2054 - 2061
  • [9] Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (Medpor)
    De Potter, P
    Duprez, T
    Cosnard, G
    [J]. OPHTHALMOLOGY, 2000, 107 (09) : 1656 - 1660
  • [10] Orbital myiasis in a patient with a chronically exposed hydroxyapatite implant
    Devoto, MH
    Zaffaroni, MC
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 20 (05) : 395 - 396