A Comparison of the Handling and Accuracy of Syringe and Vial Versus Prefilled Insulin Pen (FlexPen)

被引:45
作者
Asakura, Toshinari [1 ,2 ]
Seino, Hiroaki [2 ,3 ]
Nakano, Reiko [4 ]
Muto, Tatsuya [5 ]
Toraishi, Kenichi [6 ]
Sako, Yasuhiro
Kageyama, Miho [2 ]
Yohkoh, Noriaki
机构
[1] Niigata Univ Pharm & Appl Life Sci, Dept Clin Pharm, Fac Pharmaceut Sci, Akiha Ku, Niigata 9568603, Japan
[2] Ohta Nishinouchi Hosp, Dept Diabet Ctr, Ohta, Gunma, Japan
[3] Seino Clin, Koriyama, Fukushima, Japan
[4] Manda Mem Hosp, Dept Pharm, Manda, Japan
[5] Aichi Med Univ, Sch Med, Toyohashi, Aichi, Japan
[6] Saiseikai Fukuoka Gen Hosp, Dept Pharm, Fukuoka, Japan
关键词
DIABETIC-PATIENTS; DOSING ACCURACY; INJECTION; EFFICACY; SAFETY;
D O I
10.1089/dia.2009.0006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To determine the preferable method for self-injecting insulin, we compared the handling, safety, and dose accuracy of a conventional disposable syringe and vial with FlexPen (R) (Novo Nordisk A/S, Bagsvaerd, Denmark), a prefilled pen. Methods: Insulin therapy-naive healthcare professionals (HCPs) (n = 30), unfamiliar with insulin delivery, injected 10 U of insulin into a sponge pad using either a syringe and vial or the FlexPen, both with 30-gauge 8-mm needles, on day 1. The following day, they used the alternative method. They evaluated the handling of the two methods on device-specific questionnaires and compared overall preference on a third questionnaire. To evaluate dose accuracy, 30 insulin therapy-experienced HCPs and 20 insulin therapy-naive HCPs were asked to deliver 10 U of insulin using each method, and the amount discharged was weighed. Results: FlexPen was rated easier to use and overall more preferable than the syringe and vial by insulin therapy-naive HCPs (P < 0.001). The pen device was more accurate than the syringe and vial when used by experienced HCPs ( mean +/- SD dose delivered, 9.91 +/- 0.11U vs. 9.82 +/- 0.25 U, respectively; P < 0.001) and by insulin therapy-naive HCPs ( 9.91 +/- 0.12U vs. 9.74 +/- 0.85 U; P < 0.001). Conclusions: Insulin therapy-naive HCPs found FlexPen easier to handle and preferable to use compared to a conventional syringe and vial. Both insulin therapy-experienced and -naive HCPs were able to deliver insulin significantly more accurately with the FlexPen than with a syringe and vial (P < 0.001).
引用
收藏
页码:657 / 661
页数:5
相关论文
共 26 条
[1]  
*AM DIAB ASS, 2004, LIF DIAB, P184
[2]  
[Anonymous], 2006, DIAB ATL, P95
[3]  
Asakura T, 2005, DIABETES, V54, pA498
[4]  
ASAKURA T, 2001, J NEW REMEDIES CLIN, V2177, P941
[5]  
ASAKURA T, 2004, PHARMA MED, V23, P129
[6]  
ASAKURA T, 2005, IYAKU J, V41, P2295
[7]  
ASAKURA T, 1996, PRACTICE, V13, P575
[8]  
ASAKURA T, 2005, J CLIN RES, V8, P33
[9]  
ASAKURA T, 2003, GUIDEBOOK NOVOLIN R
[10]  
ASAKURA T, 1996, PRACTICE, V13, P263