Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient's pain and anxiety

被引:18
作者
Contesini, Massimiliano [1 ]
Guberti, Monica [2 ]
Saccani, Roberta [3 ]
Braglia, Luca [4 ]
Iotti, Cinzia [3 ]
Botti, Andrea [5 ]
Abbati, Emilio [3 ]
Iemmi, Marina [2 ]
机构
[1] Azienda Unita Sanit Locale, Human Resource Dev Training, Reggio Emilia, Italy
[2] Arcispedale Santa Maria Nuova IRCCS, Nursing Directorate, Reggio Emilia, Italy
[3] Arcispedale S Maria Nuova IRCCS, Radiat Oncol Dept, Reggio Emilia, Italy
[4] Arcispedale S Maria Nuova IRCCS, Sci Directorate, Reggio Emilia, Italy
[5] Arcispedale S Maria Nuova IRCCS, Med Phys Dept, Reggio Emilia, Italy
来源
RADIATION ONCOLOGY | 2017年 / 12卷
关键词
HNC; IMRT; Setup error; Pain; Anxiety; Customised immobilisation systems; IMAGE-GUIDANCE; UP ERRORS;
D O I
10.1186/s13014-017-0807-y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: In patients with head-neck cancer treated with IMRT, immobility of the upper part of the body during radiation is maintained by means of customised immobilisation devices. The main purpose of this study was to determine how the procedures for preparation of customised immobilisation systems and the patients characteristics influence the extent of setup errors. Methods: A longitudinal, prospective study involving 29 patients treated with IMRT. Data were collected before CT simulation and during all the treatment sessions (528 setup errors analysed overall); the correlation with possible risk factors for setup errors was explored using a linear mixed model. Results: Setup errors were not influenced by the patient's anxiety and pain. Temporary removal of the thermoplastic mask before carrying out the CT simulation shows statistically borderline, clinically relevant, increase of setup errors (+ 24.7%, 95% CI: -0.5% -55.8%). Moreover, a unit increase of radiation therapists who model the customised thermoplastic mask is associated to a -18% (-29.2% - -4.9%) reduction of the errors. The setup error is influenced by the patient's physical features; in particular, it increases both in patients in whom the treatment position is obtained with 'Shoulder down' (+ 27.9%, 2.2% -59.7%) and in patients with 'Scoliosis/kyphosis' problems (+ 65.4%, 2.3% - 164.2%). Using a 'Small size standard plus customized neck support device' is associated to a -52.3% (-73.7% - -11.2%) reduction. The increase in number of radiation therapists encountered during the entire treatment cycle does not show associations. Increase in the body mass index is associated with a slight reduction in setup error by (-2.8%, -5% - -0.7%). Conclusion: The position of the patient obtained by forcing the shoulders downwards, clinically significant scoliosis or kyphosis and the reduction of the number of radiation therapists who model the thermoplastic mask are found to be statistically significant risk factors that can cause an increase in setup errors, while the use of 'Small size' neck support device and patient BMI can diminish them.
引用
收藏
页数:7
相关论文
共 28 条
[1]  
[Anonymous], 2011, HDB PAIN ASSESSMENT
[2]  
[Anonymous], 2014, LINEAR MIXED MODELS, DOI DOI 10.1201/B17198
[3]   Comparison of two dead and neck immobilization systems [J].
Bentel, GC ;
Marks, LB ;
Hendren, K ;
Brizel, DM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04) :867-873
[4]   Clinical challenges in the implementation of a tomotherapy service for head and neck cancer patients in a regional UK radiotherapy centre [J].
Chatterjee, S. ;
Mott, J. H. ;
Smyth, G. ;
Dickson, S. ;
Dobrowsky, W. ;
Kelly, C. G. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1000) :358-366
[5]   EVALUATION OF THE PLANNING TARGET VOLUME IN THE TREATMENT OF HEAD AND NECK CANCER WITH INTENSITY-MODULATED RADIOTHERAPY: WHAT IS THE APPROPRIATE EXPANSION MARGIN IN THE SETTING OF DAILY IMAGE GUIDANCE? [J].
Chen, Allen M. ;
Farwell, D. Gregory ;
Luu, Quang ;
Donald, Paul J. ;
Perks, Julian ;
Purdy, James A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (04) :943-949
[6]   MULTI-SYSTEM VERIFICATION OF REGISTRATIONS FOR IMAGE-GUIDED RADIOTHERAPY IN CLINICAL TRIALS [J].
Cui, Yunfeng ;
Galvin, James M. ;
Straube, William L. ;
Bosch, Walter R. ;
Purdy, James A. ;
Li, X. Allen ;
Xiao, Ying .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (01) :305-312
[7]  
De Bari B, 2012, RADIOL MED, V117, P885, DOI 10.1007/s11547-011-0765-7
[8]   Assessment of residual setup errors for anatomical sub-structures in image-guided head-and-neck cancer radiotherapy [J].
Djordjevic, Milos ;
Sjoholm, Emmelie ;
Tullgren, Owe ;
Sorcini, Bruno .
ACTA ONCOLOGICA, 2014, 53 (05) :646-653
[9]   STUDIES WITH PAIN RATING-SCALES [J].
DOWNIE, WW ;
LEATHAM, PA ;
RHIND, VM ;
WRIGHT, V ;
BRANCO, JA ;
ANDERSON, JA .
ANNALS OF THE RHEUMATIC DISEASES, 1978, 37 (04) :378-381
[10]   Prevalence of pain in patients with cancer: a systematic review of the past 40 years [J].
Everdingen, M. H. J. Van den Beuken-Van ;
De Rijke, J. M. ;
Kessel, A. G. ;
Schouten, H. C. ;
Van Kleef, M. ;
Patijn, J. .
ANNALS OF ONCOLOGY, 2007, 18 (09) :1437-1449