Nucleate boiling of low GWP refrigerants on highly enhanced tube surface

被引:39
作者
Gorgy, Evraam [1 ]
机构
[1] Great Lakes Thermal Technol Inc, Decatur, GA 30035 USA
关键词
Low GWP refrigerants; Nucleate boiling; Enhanced surfaces; Flooded evaporators; Modified Wilson Plot; Internal flow correlation; HEAT-TRANSFER; BUNDLE; SMOOTH; R-134A; R-123; FLOW;
D O I
10.1016/j.ijheatmasstransfer.2016.01.057
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the experimental investigation of the heat transfer performance of alternative low GWP (Global Warming Potential) refrigerants during nucleate boiling. The fluids used in the study are R-1234ze, R-1233zd(E), and R-450A. The first two HFOs (hydro-fluoro-olefins) have a GWP index less than or equal to 1 while the zeotropic blend R-450a has a GWP index of 547. This study compared R-1234ze and R-450A to their targeted replacement, R-134a, and compared R-1233zd(E) to R-123 using a highly enhanced tube surface. Tests were conducted at a heat flux range of 10-110 kW/m(2) and at a saturation temperature of 4.44 degrees C. Results show that the performance of R-1234ze is very similar to that of R-134a while R-450a shows performance degradation of 28% compared to R-134a. For the R-123 replacement, R-1233zd(E) demonstrates a noticeable 19% performance increase. The results section includes a power-law model to predict the refrigerant-side heat transfer coefficient for all five fluids. Meanwhile, the heat flux used in the model covers a range of 10-60 kW/m(2), a typical range of interest for refrigerant evaporator design. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:660 / 666
页数:7
相关论文
共 26 条
[1]  
[Anonymous], INT J HEAT MASS TRAN
[2]  
Briggs D.E., 1969, Chemical Engineering Progress Symposium Series, V65, P35
[3]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[4]  
Gorgy E.I., 2011, THESIS KANSAS STATE
[5]   Convective boiling of R-134a and R-123 on an enhanced tube bundle with standard pitch, RP-1316 [J].
Gorgy, Evraam ;
Eckels, Steven .
HVAC&R RESEARCH, 2013, 19 (02) :193-206
[6]   Average Heat Transfer Coefficient for Pool Boiling of R-134a and R-123 on Smooth and Enhanced Tubes (RP-1316) [J].
Gorgy, Evraam ;
Eckels, Steven .
HVAC&R RESEARCH, 2010, 16 (05) :657-676
[7]  
Kedzierski M., 2013, 1807 NIST, V1807
[8]   Nucleate pool boiling on structured enhanced tubes having pores with connecting gaps [J].
Kim, NH ;
Choi, KK .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (01) :17-28
[9]  
Kline S.J., 1952, ASME Mechanical Engineering, V75, P3
[10]   RELATIVE CONTRIBUTIONS OF GREENHOUSE GAS EMISSIONS TO GLOBAL WARMING [J].
LASHOF, DA ;
AHUJA, DR .
NATURE, 1990, 344 (6266) :529-531