Generation of a square wave inductively coupled plasma scanning mass spectrometry signal using electrothermal vaporization sample introduction

被引:9
作者
Balsanek, WJ
Venable, JD
Holcombe, JA [1 ]
机构
[1] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
[2] Scripps Res Inst, Dept Cell Biol, La Jolla, CA 92037 USA
关键词
D O I
10.1039/b206143k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A device was designed to convert the typical skewed gaussian shaped signal from an inductively coupled plasma mass spectrometer (ICP-MS) using electrothermal vaporization (ETV) into a square wave signal. The basis for such a transformation is centered on the assumption that the aerosol particles produced from ETV are aerodynamically small, and thus, have diffusive properties similar to gases, which makes them easy to mix and resistant to loss by settling. The ETV square wave signals were generated through the use of a stainless steel cylinder equipped with a motor driven piston assembly, which was used to trap the transient ETV signal and deliver a uniform density aerosol to the ICP-MS. The length of the signal was controlled by the rate of travel of the piston during expulsion of the sample aerosol. A constant flow rate was achieved and maintained using a pressure sensor feedback to the motor driving the piston. The system was evaluated by quantitative full mass scans on a variety of signal shapes including square wave signals, normal ETV signals, and broadened ETV signals generated with the use of a single bead string reactor (SBSR). The square wave signals yielded precisions for quantitative full mass scans of better than 10% RSD for most metals compared to approximately 15% for SBSR broadened signals and 40% for normal signals. The improved precision was attributed to an increased duty cycle, but the increase did not become significant until more than 100 masses were monitored due to the relatively small amount of "temporal overhead time'' (fly-back time, amplifier settling time, etc.) relative to data collection periods. Because the ETV generated aerosol consists of aerodynamically small particles, there was only a minimal decrease (<2-11%) in the integrated signal area as a result of using the square wave generator.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 13 条
[1]   Theoretical description and experimental observation of aerosol transport processes in laser ablation inductively coupled plasma mass spectrometry [J].
Bleiner, D ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) :449-456
[2]   ANALYTE TRANSPORT STUDIES OF AQUEOUS-SOLUTIONS AND SLURRY SAMPLES USING ELECTROTHERMAL VAPORIZATION ICP-MS [J].
FONSECA, RW ;
MILLERIHLI, NJ .
APPLIED SPECTROSCOPY, 1995, 49 (10) :1403-1410
[3]   Analyte transport efficiency with electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Grégoire, DC ;
Sturgeon, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (05) :773-786
[4]   Thermophoretic collection and analysis of submicrometer Ag particles emitted from a graphite tube-type electrothermal vaporizer [J].
Langer, D ;
Holcombe, JA .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :582-588
[5]   Simple transient extension chamber to permit full mass scans with electrothermal vaporization inductively coupled plasma mass spectrometry [J].
Langer, D ;
Holcombe, JA .
APPLIED SPECTROSCOPY, 1999, 53 (10) :1244-1250
[6]  
MOENKEBLANKENBURG L, 1990, ROY SOC CH, V85, P1
[7]   Evaluation of the multi-element capabilities of electrothermal vaporization quadrupole-based ICP mass spectrometry [J].
Resano, M ;
Verstraete, M ;
Vanhaecke, F ;
Moens, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :1018-1027
[8]   PARTICLE-SIZE DISTRIBUTION OF SAMPLE TRANSPORTED FROM AN ELECTROTHERMAL VAPORIZER TO AN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETER [J].
SPARKS, CM ;
HOLCOMBE, J ;
PINKSTON, TL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (13) :1607-1615
[9]   Peak broadening from an electrothermal vaporization sample introduction source into an inductively coupled plasma [J].
Venable, J ;
Holcombe, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (08) :1431-1440
[10]   Optimizing the multielement analysis capabilities of an ICP quadrupole mass spectrometer using electrothermal vaporization sample introduction [J].
Venable, JD ;
Langer, D ;
Holcombe, JA .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3744-3753