Metallic stents in malignant biliary obstruction: Prospective long-term clinical results

被引:115
作者
Lee, BH
Choe, DH
Lee, JH
Kim, KH
Chin, SY
机构
[1] Department of Radiology, Korea Cancer Center Hospital, Nowon-gu, Seoul, 139-706
关键词
D O I
10.2214/ajr.168.3.9057527
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this prospective study was to evaluate the long-term clinical efficacy of metallic stents when used as the initial palliative treatment of patients with inoperable malignant biliary obstruction. SUBJECTS AND METHODS. From August 1991 through May 1995, 100 consecutive patients with malignant biliary obstruction were treated with percutaneous placement of metallic stents. The causes of obstruction were bile duct carcinoma (n = 50), pancreatic carcinoma (n = 17), gallbladder carcinoma (n = 6), hepatocellular carcinoma (n = 2), and metastatic lymphadenopathy in the hepatoduodenal ligament (n = 25). We used 123 stents: 64 Gianturco Z stents, 39 Hanaro spiral stents, 16 Wallstents, two tantalum Strecker stents, one Endocoil stent, and one Memotherm nitinol stent. Every 3 months we followed up all patients except those who died. The average length of follow-up was 220 days (range, 4-1125 days). Patient survival and stent patency rates were estimated by life-table analysis. RESULTS. The median length of survival for the entire patient group was 246 days: 25-week and 50-week survival rates were 62% and 25%, respectively. We found no statistically significant difference in the median length of survival between patients with hilar obstruction (256 days) and patients with common bile duct (CBD) obstruction (227 days). Patients with bile duct carcinoma had longer median survival (269 days) than did patients with other conditions (197 days). The overall median length of patency for all stents was 360 days; the 25-week and 50-week patency rates were 81% and 53%, respectively. The stent patency rate at the median length of survival was 71%. The median length of stent patency in patients with hilar obstruction (617 days) was nearly double that of patients with CBD obstruction (324 days). However, the median length of stent patency in patients with bile duct carcinoma showed no statistically significant difference from the median length in patients with other diseases. Four patients (4%) died within 1 month after stent placement. Twenty-one patients (21%) developed recurrent jaundice or cholangitis. In order of frequency, the causes of recurrent jaundice were tumor overgrowth, incrustation of bile sludge, duodenal obstruction due to tumor invasion, stent impaction into the bile duct wall, stent malposition, and tumor ingrowth. CONCLUSION. Metallic stents showed a favorable patency rate with regard to patient survival. In patients with hilar obstruction, the clinical efficacy of metallic stents was superior to that in patients with CBD obstruction. We believe that placement of metallic stents is the procedure of choice for palliation of malignant biliary obstruction.
引用
收藏
页码:741 / 745
页数:5
相关论文
共 24 条
  • [1] SELF-EXPANDABLE STAINLESS-STEEL ENDOPROSTHESES FOR TREATMENT OF MALIGNANT BILE-DUCT OBSTRUCTION
    ADAM, A
    CHETTY, N
    RODDIE, M
    YEUNG, E
    BENJAMIN, IS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (02) : 321 - 325
  • [2] Becker C D, 1993, J Vasc Interv Radiol, V4, P597, DOI 10.1016/S1051-0443(93)71930-2
  • [3] SELF-EXPANDABLE NITINOL STENT FOR THE MANAGEMENT OF BILIARY OBSTRUCTION - LONG-TERM CLINICAL-RESULTS
    BEZZI, M
    ORSI, F
    SALVATORI, FM
    MACCIONI, F
    ROSSI, P
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (02) : 287 - 293
  • [4] MALIGNANT BILIARY OBSTRUCTION - CLINICAL AND HISTOPATHOLOGIC CORRELATION AFTER TREATMENT WITH SELF-EXPANDING METAL PROSTHESES
    BOGUTH, L
    TATALOVIC, S
    ANTONUCCI, F
    HEER, M
    SULSER, H
    ZOLLIKOFER, CL
    [J]. RADIOLOGY, 1994, 192 (03) : 669 - 674
  • [5] DAVIDS PHP, 1992, LANCET, V340, P19
  • [6] Dick B W, 1990, J Vasc Interv Radiol, V1, P97, DOI 10.1016/S1051-0443(90)72511-0
  • [7] SELF-EXPANDABLE STAINLESS-STEEL BRAIDED ENDOPROSTHESIS FOR BILIARY STRICTURES
    GILLAMS, A
    DICK, R
    DOOLEY, JS
    WALLSTEN, H
    ELDIN, A
    [J]. RADIOLOGY, 1990, 174 (01) : 137 - 140
  • [8] MALIGNANT BILIARY OBSTRUCTION - TREATMENT WITH EXPANDABLE METALLIC STENTS - FOLLOW-UP OF 50 CONSECUTIVE PATIENTS
    GORDON, RL
    RING, EJ
    LABERGE, JM
    DOHERTY, MM
    [J]. RADIOLOGY, 1992, 182 (03) : 697 - 701
  • [9] GIANTURCO EXPANDABLE METALLIC BILIARY STENTS - RESULTS OF A EUROPEAN CLINICAL-TRIAL
    IRVING, JD
    ADAM, A
    DICK, R
    DONDELINGER, RF
    LUNDERQUIST, A
    ROCHE, A
    [J]. RADIOLOGY, 1989, 172 (02) : 321 - 326
  • [10] A NEW BALLOON-EXPANDABLE TANTALUM STENT (STRECKER-STENT) FOR THE BILIARY SYSTEM - PRELIMINARY EXPERIENCE
    JASCHKE, W
    KLOSE, KJ
    STRECKER, EP
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (06) : 356 - 359