Magnetic Solid-Phase Extraction and Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Hexachlorophene in Cosmetics

被引:19
|
作者
Liu, Ruiqi [1 ]
Liu, Ye [2 ]
Cheng, Chunsheng [3 ]
Yang, Yaling [1 ]
机构
[1] Kunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Peoples R China
[2] Yunnan Salt & Salt Chem Co Ltd, Kunming 650200, Peoples R China
[3] Kunming Univ Sci & Technol, Yunnan Prov Food Safety Res Inst, Kunming 650500, Peoples R China
关键词
High-performance liquid chromatography; Magnetic solid-phase extraction; Ionic liquid dispersive liquid-liquid microextraction; Cosmetics; Hexachlorophene; POLYCYCLIC AROMATIC-HYDROCARBONS; GAS-CHROMATOGRAPHY; SPECTROMETRIC DETERMINATION; WATER; PRECONCENTRATION; QUANTITIES; POLLUTANTS; GC;
D O I
10.1007/s10337-017-3283-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An efficient, simple, and fast method based on ionic liquid dispersive liquid-liquid microextraction (IL-DLLME) followed by magnetic solid-phase extraction (MSPE) was developed as a new technique for extracting and purifying hexachlorophene (HCP) in cosmetics prior to high-performance liquid chromatography (HPLC) determination. In this method based on IL-DLLME and MSPE, 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) is used as the extraction solvent and Fe3O4 nanoparticles are used to remove hydrophobic additives in the cosmetics by physical adsorption. The main parameters affecting the efficiency of the IL-DLLME and MSPE of HCP were investigated and optimized. Under the optimum conditions, the method was linear in the range 0.5-40 A mu g mL(-1) with a correlation coefficient (R (2)) of 0.9976 and had a detection limit of 0.14 A mu g mL(-1) at a signal-to-noise ratio (S/N) of 3. The recoveries of HCP in three cosmetic samples using the proposed method were in the range 74.5-97.7%, and the relative standard deviations (RSD, n = 5) were in the range 3.8-6.7%. The developed method was successfully applied to the determination of HCP in cosmetics.
引用
收藏
页码:783 / 791
页数:9
相关论文
共 50 条
  • [21] Ionic liquid-based dispersive liquid–liquid microextraction followed by magnetic solid-phase extraction for determination of quinolones
    Jiawei Hong
    Xiaomei Liu
    Xiuying Yang
    Yousheng Wang
    Longshan Zhao
    Microchimica Acta, 2022, 189
  • [22] In-syringe ionic liquid dispersive liquid-liquid microextraction for the determination of sulfonamides in blood using high-performance liquid chromatography
    Yu, Wei
    Liu, Zhongling
    Cui, Shusen
    Zhang, Shaohua
    Yang, Xiao
    Lei, Lei
    Zhang, Hanqi
    Yu, Aimin
    ANALYTICAL METHODS, 2014, 6 (08) : 2545 - 2552
  • [23] DETERMINATION OF TETRACYCLINES IN WATER BY ETHYL ACETATE-IONIC LIQUID DISPERSIVE LIQUID-LIQUID MICROEXTRACTION AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Du, Dongli
    Wu, Yuanyuan
    Kang, Duan
    Wang, Huili
    Huang, Changjiang
    Li, Yanyan
    ANALYTICAL LETTERS, 2014, 47 (10) : 1783 - 1795
  • [24] Determination of Aristocularine Enantiomers by Dispersive Liquid-Liquid Microextraction and Chiral High-performance Liquid Chromatography
    Ruiz-Rodriguez, L.
    Aguilar, A.
    Garcia Sanchez, F.
    Diaz, A. N.
    ANALYTICAL LETTERS, 2017, 50 (10) : 1568 - 1579
  • [25] Vortex-Assisted Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Triazole Fungicides in Fruit Juices
    Yaohai Zhang
    Yan Zhang
    Qiyang Zhao
    Weijun Chen
    Bining Jiao
    Food Analytical Methods, 2016, 9 : 596 - 604
  • [26] Vortex-Assisted Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Triazole Fungicides in Fruit Juices
    Zhang, Yaohai
    Zhang, Yan
    Zhao, Qiyang
    Chen, Weijun
    Jiao, Bining
    FOOD ANALYTICAL METHODS, 2016, 9 (03) : 596 - 604
  • [27] Ionic liquid foam floatation coupled with ionic liquid dispersive liquid-liquid microextraction for the separation and determination of estrogens in water samples by high-performance liquid chromatography with fluorescence detection
    Zhang, Rui
    Wang, Chuanliu
    Yue, Qiaohong
    Zhou, Tiecheng
    Li, Na
    Zhang, Hanqi
    Hao, Xiaoke
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (21) : 3133 - 3141
  • [28] Determination of trace bisphenol A in environmental water by high-performance liquid chromatography using magnetic reduced graphene oxide based solid-phase extraction coupled with dispersive liquid–liquid microextraction
    Danping Li
    Xiaoguo Ma
    Rui Wang
    Yumian Yu
    Analytical and Bioanalytical Chemistry, 2017, 409 : 1165 - 1172
  • [29] Simultaneous Determination of Permethrin and Deltamethrin in Water Samples by Magnetic Solid-phase Extraction coupled with Dispersive Liquid-Liquid Microextraction combined with Gas Chromatography
    Noori, Arezoo Hassan
    Rezaee, Mohammad
    Kazemipour, Maryam
    Mashayekhi, Hossein Ali
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2017, 70 : 200 - 208
  • [30] Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for Determination of Coumarin Compounds in Radix Angelicae Dahuricae
    Li, Li Hua
    Zhang, Hong Fen
    Hu, Shuang
    Bai, Xiao Hong
    Li, Shang
    CHROMATOGRAPHIA, 2012, 75 (3-4) : 131 - 137