Magnetic Solid-Phase Extraction and Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Hexachlorophene in Cosmetics

被引:20
作者
Liu, Ruiqi [1 ]
Liu, Ye [2 ]
Cheng, Chunsheng [3 ]
Yang, Yaling [1 ]
机构
[1] Kunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Peoples R China
[2] Yunnan Salt & Salt Chem Co Ltd, Kunming 650200, Peoples R China
[3] Kunming Univ Sci & Technol, Yunnan Prov Food Safety Res Inst, Kunming 650500, Peoples R China
关键词
High-performance liquid chromatography; Magnetic solid-phase extraction; Ionic liquid dispersive liquid-liquid microextraction; Cosmetics; Hexachlorophene; POLYCYCLIC AROMATIC-HYDROCARBONS; GAS-CHROMATOGRAPHY; SPECTROMETRIC DETERMINATION; WATER; PRECONCENTRATION; QUANTITIES; POLLUTANTS; GC;
D O I
10.1007/s10337-017-3283-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An efficient, simple, and fast method based on ionic liquid dispersive liquid-liquid microextraction (IL-DLLME) followed by magnetic solid-phase extraction (MSPE) was developed as a new technique for extracting and purifying hexachlorophene (HCP) in cosmetics prior to high-performance liquid chromatography (HPLC) determination. In this method based on IL-DLLME and MSPE, 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) is used as the extraction solvent and Fe3O4 nanoparticles are used to remove hydrophobic additives in the cosmetics by physical adsorption. The main parameters affecting the efficiency of the IL-DLLME and MSPE of HCP were investigated and optimized. Under the optimum conditions, the method was linear in the range 0.5-40 A mu g mL(-1) with a correlation coefficient (R (2)) of 0.9976 and had a detection limit of 0.14 A mu g mL(-1) at a signal-to-noise ratio (S/N) of 3. The recoveries of HCP in three cosmetic samples using the proposed method were in the range 74.5-97.7%, and the relative standard deviations (RSD, n = 5) were in the range 3.8-6.7%. The developed method was successfully applied to the determination of HCP in cosmetics.
引用
收藏
页码:783 / 791
页数:9
相关论文
共 36 条
[1]   Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters [J].
Aguilera-Herrador, Eva ;
Lucena, Rafael ;
Cardenas, Soledad ;
Valcarcel, Miguel .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1201 (01) :106-111
[2]   The roles of ionic liquids in sorptive microextraction techniques [J].
Aguilera-Herrador, Eva ;
Lucena, Rafael ;
Cardenas, Soledad ;
Valcarcel, Miguel .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (07) :602-616
[3]  
Basiri S, 2011, INT J ENVIRON AN CH, V91, P1
[4]   ULTRAVIOLET SPECTROPHOTOMETRIC DETERMINATION OF TRACE QUANTITIES OF PHOSGENE IN GASES [J].
CRUMMETT, WB ;
MCLEAN, JD .
ANALYTICAL CHEMISTRY, 1965, 37 (03) :424-&
[5]   Determination of chlorophenols in water samples using simultaneous dispersive liquid-liquid microextraction and derivatization followed by gas chromatography-electron-capture detection [J].
Fattahi, Nazir ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani ;
Jahromi, Elham. Zeini .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :23-29
[6]   Ionic liquid-based dispersive liquid-liquid microextraction followed high-performance liquid chromatography for the determination of organophosphorus pesticides in water sample [J].
He, Lijun ;
Luo, Xianli ;
Xie, Hongxue ;
Wang, Chunjian ;
Jiang, Xiuming ;
Lu, Kui .
ANALYTICA CHIMICA ACTA, 2009, 655 (1-2) :52-59
[7]   Studies on the photocatalytic degradation of 2,3-dichlorophenol using different oxidants in aqueous solutions [J].
Kansal, S. K. ;
Kaur, G. ;
Singh, S. .
REACTION KINETICS AND CATALYSIS LETTERS, 2009, 98 (01) :177-186
[8]   PRIORITY POLLUTANTS I-A PERSPECTIVE VIEW [J].
KEITH, LH ;
TELLIARD, WA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1979, 13 (04) :416-423
[9]   ORGANIC POLLUTANTS IN WATER - IDENTIFICATION AND ANALYSIS [J].
KEITH, LH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (02) :156-162
[10]   EFFECTS OF HEXACHLOROPHENE IN RAT AND THEIR REVERSIBILITY [J].
KENNEDY, GL ;
DRESSLER, IA ;
RICHTER, WR ;
KEPLINGER, ML ;
CALANDRA, JC .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1976, 35 (01) :137-145