Magnetic Solid-Phase Extraction and Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Hexachlorophene in Cosmetics

被引:19
作者
Liu, Ruiqi [1 ]
Liu, Ye [2 ]
Cheng, Chunsheng [3 ]
Yang, Yaling [1 ]
机构
[1] Kunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650500, Peoples R China
[2] Yunnan Salt & Salt Chem Co Ltd, Kunming 650200, Peoples R China
[3] Kunming Univ Sci & Technol, Yunnan Prov Food Safety Res Inst, Kunming 650500, Peoples R China
关键词
High-performance liquid chromatography; Magnetic solid-phase extraction; Ionic liquid dispersive liquid-liquid microextraction; Cosmetics; Hexachlorophene; POLYCYCLIC AROMATIC-HYDROCARBONS; GAS-CHROMATOGRAPHY; SPECTROMETRIC DETERMINATION; WATER; PRECONCENTRATION; QUANTITIES; POLLUTANTS; GC;
D O I
10.1007/s10337-017-3283-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An efficient, simple, and fast method based on ionic liquid dispersive liquid-liquid microextraction (IL-DLLME) followed by magnetic solid-phase extraction (MSPE) was developed as a new technique for extracting and purifying hexachlorophene (HCP) in cosmetics prior to high-performance liquid chromatography (HPLC) determination. In this method based on IL-DLLME and MSPE, 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) is used as the extraction solvent and Fe3O4 nanoparticles are used to remove hydrophobic additives in the cosmetics by physical adsorption. The main parameters affecting the efficiency of the IL-DLLME and MSPE of HCP were investigated and optimized. Under the optimum conditions, the method was linear in the range 0.5-40 A mu g mL(-1) with a correlation coefficient (R (2)) of 0.9976 and had a detection limit of 0.14 A mu g mL(-1) at a signal-to-noise ratio (S/N) of 3. The recoveries of HCP in three cosmetic samples using the proposed method were in the range 74.5-97.7%, and the relative standard deviations (RSD, n = 5) were in the range 3.8-6.7%. The developed method was successfully applied to the determination of HCP in cosmetics.
引用
收藏
页码:783 / 791
页数:9
相关论文
共 36 条
  • [1] Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters
    Aguilera-Herrador, Eva
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1201 (01) : 106 - 111
  • [2] The roles of ionic liquids in sorptive microextraction techniques
    Aguilera-Herrador, Eva
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (07) : 602 - 616
  • [3] Basiri S, 2011, INT J ENVIRON AN CH, V91, P1
  • [4] ULTRAVIOLET SPECTROPHOTOMETRIC DETERMINATION OF TRACE QUANTITIES OF PHOSGENE IN GASES
    CRUMMETT, WB
    MCLEAN, JD
    [J]. ANALYTICAL CHEMISTRY, 1965, 37 (03) : 424 - &
  • [5] Determination of chlorophenols in water samples using simultaneous dispersive liquid-liquid microextraction and derivatization followed by gas chromatography-electron-capture detection
    Fattahi, Nazir
    Assadi, Yaghoub
    Hosseini, Mohammad Reza Milani
    Jahromi, Elham. Zeini
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) : 23 - 29
  • [6] Ionic liquid-based dispersive liquid-liquid microextraction followed high-performance liquid chromatography for the determination of organophosphorus pesticides in water sample
    He, Lijun
    Luo, Xianli
    Xie, Hongxue
    Wang, Chunjian
    Jiang, Xiuming
    Lu, Kui
    [J]. ANALYTICA CHIMICA ACTA, 2009, 655 (1-2) : 52 - 59
  • [7] Studies on the photocatalytic degradation of 2,3-dichlorophenol using different oxidants in aqueous solutions
    Kansal, S. K.
    Kaur, G.
    Singh, S.
    [J]. REACTION KINETICS AND CATALYSIS LETTERS, 2009, 98 (01): : 177 - 186
  • [8] PRIORITY POLLUTANTS I-A PERSPECTIVE VIEW
    KEITH, LH
    TELLIARD, WA
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1979, 13 (04) : 416 - 423
  • [9] ORGANIC POLLUTANTS IN WATER - IDENTIFICATION AND ANALYSIS
    KEITH, LH
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (02) : 156 - 162
  • [10] EFFECTS OF HEXACHLOROPHENE IN RAT AND THEIR REVERSIBILITY
    KENNEDY, GL
    DRESSLER, IA
    RICHTER, WR
    KEPLINGER, ML
    CALANDRA, JC
    [J]. TOXICOLOGY AND APPLIED PHARMACOLOGY, 1976, 35 (01) : 137 - 145