Extending metabolome coverage for untargeted metabolite profiling of adherent cultured hepatic cells

被引:31
作者
Carlos Garcia-Canaveras, Juan [1 ,3 ]
Lopez, Silvia [1 ,2 ]
Vicente Castell, Jose [1 ,2 ,3 ]
Teresa Donato, M. [1 ,2 ,3 ]
Lahoz, Agustin [1 ]
机构
[1] Fdn Hosp La Fe, Inst Invest Sanitaria, Unidad Analit, Unidad Hepatol Expt, Ave Fernando Abril Martorell 106, Valencia 46026, Spain
[2] FIS, Ctr Invest Biomed Red Enfermedades Hepat & Digest, CIBERehd, Barcelona, Spain
[3] Univ Valencia, Fac Med & Odontol, Dept Bioquim & Biol Mol, Ave Blasco Ibanez 15, Valencia 46010, Spain
关键词
LC-MS; Bioanalytical methods; HPLC; Mass spectrometry; Process analysis; Sampling; Metabolomics; MASS-SPECTROMETRY; SAMPLE PREPARATION; MAMMALIAN-CELLS; CHROMATOGRAPHY; EXTRACTION; OPTIMIZATION; TISSUE; INVESTIGATE; FLUIDS; TIME;
D O I
10.1007/s00216-015-9227-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
MS-based metabolite profiling of adherent mammalian cells comprises several challenging steps such as metabolism quenching, cell detachment, cell disruption, metabolome extraction, and metabolite measurement. In LC-MS, the final metabolome coverage is strongly determined by the separation technique and the MS conditions used. Human liver-derived cell line HepG2 was chosen as adherent mammalian cell model to evaluate the performance of several commonly used procedures in both sample processing and LC-MS analysis. In a first phase, metabolite extraction and sample analysis were optimized in a combined manner. To this end, the extraction abilities of five different solvents (or combinations) were assessed by comparing the number and the levels of the metabolites comprised in each extract. Three different chromatographic methods were selected for metabolites separation. A HILIC-based method which was set to specifically separate polar metabolites and two RP-based methods focused on lipidome and wide-ranging metabolite detection, respectively. With regard to metabolite measurement, a Q-ToF instrument operating in both ESI (+) and ESI (-) was used for unbiased extract analysis. Once metabolite extraction and analysis conditions were set up, the influence of cell harvesting on metabolome coverage was also evaluated. Therefore, different protocols for cell detachment (trypsinization or scraping) and metabolism quenching were compared. This study confirmed the inconvenience of trypsinization as a harvesting technique, and the importance of using complementary extraction solvents to extend metabolome coverage, minimizing interferences and maximizing detection, thanks to the use of dedicated analytical conditions through the combination of HILIC and RP separations. The proposed workflow allowed the detection of over 300 identified metabolites from highly polar compounds to a wide range of lipids.
引用
收藏
页码:1217 / 1230
页数:14
相关论文
共 49 条
[1]   Metabolomics analysis II. Preparation of biological samples prior to detection [J].
Alvarez-Sanchez, B. ;
Priego-Capote, F. ;
Luque de Castro, M. D. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (02) :120-127
[2]   ENERGY CHARGE OF ADENYLATE POOL AS A REGULATORY PARAMETER . INTERACTION WITH FEEDBACK MODIFIERS [J].
ATKINSON, DE .
BIOCHEMISTRY, 1968, 7 (11) :4030-&
[3]   Metabolic profiling of HepG2 cells incubated with S(-) and R(+) enantiomers of anti-coagulating drug warfarin [J].
Bai, Jing ;
Wang, Ming Xuan ;
Chowbay, Balram ;
Ching, Chi Bun ;
Chen, Wei Ning .
METABOLOMICS, 2011, 7 (03) :353-362
[4]   Optimization of harvesting, extraction, and analytical protocols for UPLC-ESI-MS-based metabolomic analysis of adherent mammalian cancer cells [J].
Bi, Huichang ;
Krausz, Kristopher W. ;
Manna, Soumen K. ;
Li, Fei ;
Johnson, Caroline H. ;
Gonzalez, Frank J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (15) :5279-5289
[5]   Metabolomic signatures in lipid-loaded HepaRGs reveal pathways involved in steatotic progression [J].
Brown, Meredith V. ;
Compton, Sarah A. ;
Milburn, Michael V. ;
Lawton, Kay A. ;
Cheatham, Bentley .
OBESITY, 2013, 21 (12) :E561-E570
[6]   GC-TOFMS analysis of metabolites in adherent MDCK cells and a novel strategy for identifying intracellular metabolic markers for use as cell amount indicators in data normalization [J].
Cao, Bei ;
Aa, Jiye ;
Wang, Guangji ;
Wu, Xiaolan ;
Liu, Linsheng ;
Li, Mengjie ;
Shi, Jian ;
Wang, Xinwen ;
Zhao, Chunyan ;
Zheng, Tian ;
Guo, Sheng ;
Duan, Jinao .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) :2983-2993
[7]   Urinary hydrophilic and hydrophobic metabolic profiling based on liquid chromatography-mass spectrometry methods: Differential metabolite discovery specific to ovarian cancer [J].
Chen, Jing ;
Zhou, Lina ;
Zhang, Xiaoyan ;
Lu, Xin ;
Cao, Rui ;
Xu, Congjian ;
Xu, Guowang .
ELECTROPHORESIS, 2012, 33 (22) :3361-3369
[8]   Metabolomics discloses donor liver biomarkers associated with early allograft dysfunction [J].
Cortes, Miriam ;
Pareja, Eugenia ;
Garcia-Canaveras, Juan C. ;
Donato, M. Teresa ;
Montero, Sandra ;
Mir, Jose ;
Castell, Jose V. ;
Lahoz, Agustin .
JOURNAL OF HEPATOLOGY, 2014, 61 (03) :564-574
[9]   Integrated Comparison of Drug-Related and Drug-Induced Ultra Performance Liquid Chromatography/Mass Spectrometry Metabonomic Profiles Using Human Hepatocyte Cultures [J].
Croixmarie, Vincent ;
Umbdenstock, Thierry ;
Cloarec, Olivier ;
Moreau, Amelie ;
Pascussi, Jean-Marc ;
Boursier-Neyret, Claire ;
Walther, Bernard .
ANALYTICAL CHEMISTRY, 2009, 81 (15) :6061-6069
[10]   Metabolite extraction from adherently growing mammalian cells for metabolomics studies: optimization of harvesting and extraction protocols [J].
Dettmer, Katja ;
Nuernberger, Nadine ;
Kaspar, Hannelore ;
Gruber, Michael A. ;
Almstetter, Martin F. ;
Oefner, Peter J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (03) :1127-1139