Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model

被引:17
作者
Schug-Pass, C. [1 ]
Lippert, H. [2 ]
Koeckerling, F. [1 ]
机构
[1] Vivantes Hosp Spandau, Dept Surg, Ctr Minimally Invas Surg, D-13585 Berlin, Germany
[2] Otto Von Guericke Univ, Dept Surg, D-39120 Magdeburg, Germany
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2009年 / 23卷 / 12期
关键词
Abdominal wall hernia; Fibrin glue; Intraperitoneal repair; Mesh fixation; Muscle tissue; Peritoneum; INCISIONAL HERNIA REPAIR; INGUINAL-HERNIA; INTRAABDOMINAL ADHESIONS; POLYPROPYLENE MESH; HERNIOPLASTY; TITANIUM; BIOCOMPATIBILITY; IMPLANTATION; STRENGTH; TISSUCOL;
D O I
10.1007/s00464-009-0509-0
中图分类号
R61 [外科手术学];
学科分类号
摘要
In recent years, the use of fibrin glue has become an established practice in several areas of surgical treatment. For example, fibrin glue is used increasingly as an alternative method for mesh fixation in hernia surgery, significantly helping to reduce the incidence of chronic pain. The experiments in this study were aimed at elucidating the extent to which tack- or suture-based permanent fixation can be replaced by fixation with fibrin glue for laparoscopic intraperitoneal repair of abdominal wall hernias. In an initial series of experiments conducted with a biomechanical model, the strength of the fibrin glue for fixation of lightweight mesh (TiMesh light) to muscle tissue was compared with its strength of fixation to the peritoneum. In a second series of experiments, mesh was laparoscopically implanted in an established porcine model. Fibrin glue was used for mesh fixation in six animals. Laparoscopic exploration and explantation of the meshes were conducted after 4 months. Planimetric analysis was performed to investigate adhesion and shrinkage of the mesh surface. The strength of fibrin glue for fixation of mesh to the peritoneum was significantly less than for its fixation to muscle tissue (11.86 N vs. 47.88 N; p = 0.001). Three of the implanted meshes were not completely integrated, and two of these were dislocated. On the average, adhesions were seen on 16% of the mesh surfaces. The mesh shrinkage rate was 24.2%. Mesh fixation alone to the undamaged peritoneum in the intraperitoneal region cannot be recommended because of the risk for dislocation. Additional fixation using sutures, tacks, or both is needed until the mesh material is completely integrated.
引用
收藏
页码:2809 / 2815
页数:7
相关论文
共 40 条
  • [11] Evaluation of adhesion formation, mesh fixation strength, and hydroxyproline content after intraabdominal placement of polytetrafluoroethylene mesh secured using titanium spiral tacks, nitinol anchors, and polypropylene suture or polyglactin 910 suture
    Joels, CS
    Matthews, BD
    Kercher, KW
    Austin, C
    Norton, HJ
    Williams, TC
    Heniford, BT
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2005, 19 (06): : 780 - 785
  • [12] Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair
    Katkhouda, N
    Mavor, E
    Friedlander, MH
    Mason, RJ
    Kiyabu, M
    Grant, SW
    Achanta, K
    Kirkman, EL
    Narayanan, K
    Essani, R
    [J]. ANNALS OF SURGERY, 2001, 233 (01) : 18 - 25
  • [13] Katkhouda Namir, 2004, Surg Technol Int, V12, P120
  • [14] Klinge U, 1996, CHIRURG, V67, P229
  • [15] Impact of polymer pore size on the interface scar formation in a rat model
    Klinge, U
    Klosterhalfen, B
    Birkenhauer, V
    Junge, K
    Conze, J
    Schumpelick, V
    [J]. JOURNAL OF SURGICAL RESEARCH, 2002, 103 (02) : 208 - 214
  • [16] Optimal mesh size for endoscopic inguinal hernia repair - A study in a porcine model
    Knook, MTT
    van Rosmalen, AC
    Yoder, BE
    Kleinrensink, GJ
    Snijders, CJ
    Looman, CWN
    van Steensel, CJ
    [J]. SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (12): : 1471 - 1477
  • [17] Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty - A randomized prospective trial
    Lau, H
    [J]. ANNALS OF SURGERY, 2005, 242 (05) : 670 - 675
  • [18] Laparoscopic incisional hernia repair: are transfascial sutures necessary? A review of the literature
    LeBlanc, K. A.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2007, 21 (04): : 508 - 513
  • [19] Lee Meng-G Martin, 2005, Surg Innov, V12, P203, DOI 10.1177/155335060501200304
  • [20] Use of human fibrin glue (Tissucol) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty - A prospective, randomized study
    Lovisetto, Federico
    Zonta, Sandro
    Rota, Emanuela
    Mazzilli, Massimiliano
    Bardone, Marco
    Bottero, Luca
    Faillace, Giuseppe
    Longoni, Mauro
    [J]. ANNALS OF SURGERY, 2007, 245 (02) : 222 - 231