Towards improved characterisation of complex polyethylene glycol excipients using supercritical fluid chromatography-evaporative light scattering detection-mass spectrometry and comparison with size exclusion chromatography-triple detection array

被引:11
作者
Poulton, Andrew M. [1 ]
Poulten, Rebecca C. [1 ]
Baldaccini, Alice [1 ]
Gabet, Anaelle [1 ]
Mott, Rebecca [2 ]
Treacher, Kevin E. [3 ]
Roddy, Emily [1 ]
Ferguson, Paul [4 ]
机构
[1] AstraZeneca, Early Chem Dev, Pharmaceut Sci, Macclesfield, Cheshire, England
[2] AstraZeneca, Chem Dev, Pharmaceut Technol & Dev, Macclesfield, Cheshire, England
[3] AstraZeneca, New Modal Prod Dev, Pharmaceut Technol & Dev, Macclesfield, Cheshire, England
[4] AstraZeneca, Oral Prod Dev, Pharmaceut Technol & Dev, Macclesfield, Cheshire, England
关键词
Dispersity; Evaporative light scattering; Polyethylene glycol; Polymer analysis; Size exclusion chromatography; Supercritical fluid chromatography; STATIONARY PHASES;
D O I
10.1016/j.chroma.2020.461839
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of supercritical fluid chromatography (SFC) coupled to an evaporative light scattering detector (ELSD) and mass spectrometer (MS) was evaluated for the characterisation of three analogues of functionalised polyethylene glycol (PEG) 2000 (m-PEG-OH, m-PEG-cm and cm-PEG-cm (where m = OCH3 and cm = OCH2COOH)). These polymers are common excipients in drug product formulations for pharmaceuticals as they help provide the desired pharmacokinetic profile for successful drug delivery. A SFC-ELSD-MS method was developed which was selective to all three polymers, and allowed visualisation of these low UV chromophore materials. The method provided baseline resolution of the individual oligomers which allowed facile calculation of the polymer dispersity. A number of molecular weight characteristics were calculated, which showed the SFC-ELSD-MS methodology to be comparable with the current standard of analysis using size exclusion chromatography (SEC) with a triple detector array (TDA). The increased resolving power of SFC compared to SEC revealed a bimodal distribution of oligomers in the cm-PEG-cm 2000 polymer, which was not observed using SEC-TDA and exemplified SFC-ELSD as an orthogonal approach for polymer characterisation with the potential for much simpler, reduced sample and instrument preparation, calibration-less dispersity determination. When combined with SEC-TDA data, this combination allows a more complete characterisation of complex formulations excipients. (C) 2020 Published by Elsevier B.V.
引用
收藏
页数:11
相关论文
共 27 条
[11]   'Quality by Design' approach for the analysis of impurities in pharmaceutical drug products and drug substances [J].
Dispas, Amandine ;
Avohou, Hermane T. ;
Lebrun, Pierre ;
Hubert, Philippe ;
Hubert, Cedric .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 101 :24-33
[12]  
Hagen H.M., J MICROCOLUMN SEP, P27, DOI [10.10 02/mcs.1220030106., DOI 10.1002/MCS.1220030106]
[13]   Exploring the role of polymeric conjugates toward anti-cancer drug delivery: Current trends and future projections [J].
Khan, Junaid ;
Alexander, Amit ;
Ajazuddin ;
Saraf, Swarnlata ;
Saraf, Shailendra .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 548 (01) :500-514
[14]   A complete hyaluronan hydrodynamic characterization using a size exclusion chromatography-triple detector array system during in vitro enzymatic degradation [J].
La Gatta, Annalisa ;
De Rosa, Mario ;
Marzaioli, Iolanda ;
Busico, Teresa ;
Schiraldi, Chiara .
ANALYTICAL BIOCHEMISTRY, 2010, 404 (01) :21-29
[15]   Comparison of high-performance liquid chromatography and supercritical fluid chromatography using evaporative light scattering detection for the determination of plasticizers in medical devices [J].
Lecoeur, Marie ;
Decaudin, Bertrand ;
Guillotin, Yoann ;
Sautou, Valerie ;
Vaccher, Claude .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1417 :104-115
[16]   Usual, unusual and unbelievable retention behavior in achiral supercritical fluid chromatography: Review and discussion [J].
Lesellier, E. .
JOURNAL OF CHROMATOGRAPHY A, 2020, 1614
[17]   Effects of selected parameters on the response of the evaporative light scattering detector in supercritical fluid chromatography [J].
Lesellier, E. ;
Valarche, A. ;
West, C. ;
Dreux, M. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1250 :220-226
[18]   Retention mechanisms in super/subcritical fluid chromatography on packed columns [J].
Lesellier, E. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (10) :1881-1890
[19]   Characterization of low molecular weight alkoxylated polymers using long column SFC/MS and an image analysis based quantitation approach [J].
Pinkston, JD ;
Marapane, SB ;
Jordan, GT ;
Clair, BD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (10) :1195-1208
[20]  
Pyo D, 2008, B KOREAN CHEM SOC, V29, P231