Characterization of metal complexes with metallothioneins by capillary zone electrophoresis (CZE) with ICP-MS and electrospray (ES)-MS detection

被引:66
作者
Mounicou, S
Polec, K
Chassaigne, H
Potin-Gautier, M
Lobinski, R
机构
[1] Univ Pau & Pays Adour, CNRS UMR 5034, F-64053 Pau, France
[2] Warsaw Univ Technol, Fac Chem, Dept Analyt Chem, PL-00664 Warsaw, Poland
关键词
D O I
10.1039/b000546k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The complementarity of CZE-ICP-MS and CZE-ES-MS couplings was evaluated for the characterization of metal complexes with metallothionein (MT) isoforms. The preparations characterized included the rabbit liver MT and its further purified MT-1 and MT-2 isoforms. The CZE-ICP-MS electrophoregrams showed the presence of several well (often baseline) separated Gaussian-shape peaks. ES-MS was used for the identification of these signals; mass spectra taken at the peak apexes were complex and indicated the co-existence of several metal complexes (possibly with different isoforms) within each peak. Many of these complexes could be identified on the basis of the molecular mass. The study highlights the attractive potential of CZE-ICP-MS and CZE-ES-MS when used in parallel for the characterization of metal complexes with biomolecular ligands. The inherent discrepancy between the sensitivities of ICP-MS and ES-MS is partly alleviated by the fact that the metal (detected by ICP-MS) constitutes only a small fraction of the total molecule (detected by ES-MS), and by the smaller dilution factor with the makeup sheath flow in ES-MS than in ICP-MS.
引用
收藏
页码:635 / 642
页数:8
相关论文
共 43 条
[1]   Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS [J].
Baker, SA ;
Miller-Ihli, NJ .
APPLIED SPECTROSCOPY, 1999, 53 (04) :471-478
[2]   Capillary electrophoresis and inductively coupled plasma spectrometry: Status report [J].
Barnes, RM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :246-251
[3]   Strategies for the qualitative and quantitative analysis of metallothionein isoforms by capillary electrophoresis [J].
Beattie, JH .
TALANTA, 1998, 46 (02) :255-270
[4]  
Beattie JH, 1999, ELECTROPHORESIS, V20, P1613, DOI 10.1002/(SICI)1522-2683(19990601)20:7<1613::AID-ELPS1613>3.3.CO
[5]  
2-K
[6]   SEPARATION OF METALLOTHIONEIN ISOFORMS BY CAPILLARY ZONE ELECTROPHORESIS [J].
BEATTIE, JH ;
RICHARDS, MP ;
SELF, R .
JOURNAL OF CHROMATOGRAPHY, 1993, 632 (1-2) :127-135
[7]   Characterization of metallothionein isoforms by reversed-phase high-performance liquid chromatography with on-line post-column acidification and electrospray mass spectrometric detection [J].
Chassaigne, H ;
Lobinski, R .
JOURNAL OF CHROMATOGRAPHY A, 1998, 829 (1-2) :127-136
[8]   Polymorphism and identification of metallothionein isoforms by reversed-phase HPLC with on-line ion spray mass spectrometric detection [J].
Chassaigne, H ;
Lobinski, R .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2536-2543
[9]   Detection of artefacts and peak identification in reversed-phase HPLC of metallothioneins by electrospray mass spectrometry [J].
Chassaigne, H ;
Lobinski, R .
TALANTA, 1999, 48 (01) :109-118
[10]   Analysis of inorganic species by capillary electrophoresis mass spectrometry and ion exchange chromatography mass spectrometry using an ion spray source [J].
Corr, JJ ;
Anacleto, JF .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2155-2163