Direct injection liquid chromatography/positive ion electrospray ionization mass spectrometric quantification of methotrexate, folinic acid, folic acid and ondansetron in human serum

被引:49
作者
Koufopantelis, Panagiotis [1 ]
Georgakakou, Sophia [1 ]
Kazanis, Michael [1 ]
Giaginis, Costas [1 ]
Margeli, Alexandra [2 ]
Papargiri, Sophia [2 ]
Panderi, Irene [1 ]
机构
[1] Univ Athens, Sch Pharm, Div Pharmaceut Chem, GR-15771 Athens, Greece
[2] Childrens Reg Gen Hosp Agia Sofia, Athens 11527, Greece
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2009年 / 877卷 / 30期
关键词
Liquid chromatography/mass spectrometry; Methotrexate; Folinic acid; Folic acid; Ondansetron; Human serum; SOLID-PHASE EXTRACTION; HIGH-DOSE METHOTREXATE; HUMAN PLASMA; HUMAN URINE; PRECOLUMN DERIVATIZATION; OCCUPATIONAL-EXPOSURE; SURFACE CONTAMINATION; RHEUMATOID-ARTHRITIS; BIOLOGICAL-FLUIDS; RANDOMIZED-TRIAL;
D O I
10.1016/j.jchromb.2009.09.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid liquid chromatography/positive ion electrospray mass spectrometric assay (LC/ESI-MS) was developed for the quantitation of methotrexate. folinic acid, folic acid and ondansetron in human serum. The assay was based on 100 mu L serum samples, following acetonitrile precipitation of proteins and filtration that enabled direct injection into the LC/MS system. All analytes and the internal standard, alfuzosin, were separated by using a Zorbax Eclipse XDB-C-8 analytical column (2.1 mm x 150.0 mm i.d., particle size 3.5 mu m) with isocratic elution. The mobile phase was composed of a mixture of water/acetonitrile containing 0.1%, v/v formic acid (75:25, v/v), pumped at a flow rate of 0.15 mL min(-1). Quantitation of the analytes was performed with selected ion monitoring (SIM) in positive ionization mode using electrospray ionization interface. The assay was found to be linear in the concentration range of 0.01-25.00 mu g mL(-1) for methotrexate and 0.01-5.00 mu g mL(-1) for folic acid, folinic acid and ondansetron. Intermediate precision was found to be less than 4.2% over the tested concentration ranges. A run time of less than 7.0 min for each sample made it possible to analyze a large number of human serum samples per day. The method can be used to quantify methotrexate, folinic acid, folic acid and ondansetron in human serum covering a variety of clinical studies and it was applied to the analysis of human serum samples obtained from children with acute lymphoblastic leukemia. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3850 / 3856
页数:7
相关论文
共 44 条
[1]  
Albertioni F, 1996, CLIN CHEM, V42, P39
[2]   SIMULTANEOUS QUANTITATION OF METHOTREXATE AND ITS 2 MAIN METABOLITES IN BIOLOGICAL-FLUIDS BY A NOVEL SOLID-PHASE EXTRACTION PROCEDURE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ALBERTIONI, F ;
PETTERSSON, B ;
BECK, O ;
RASK, C ;
SEIDEMAN, P ;
PETERSON, C .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (01) :163-170
[3]  
[Anonymous], 2001, Guidance for industry: bioanalytical method validation
[4]   Folic acid supplements are good (not bad) for rheumatoid arthritis patients treated with low-dose methotrexate [J].
Baggott, Joseph E. ;
Morgan, Sarah L. .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2008, 88 (02) :479-480
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF METHOTREXATE, 7-HYDROXYMETHOTREXATE, 5-METHYLTETRAHYDROFOLIC ACID AND FOLINIC ACID IN SERUM AND CEREBROSPINAL-FLUID [J].
BELZ, S ;
FRICKEL, C ;
WOLFROM, C ;
NAU, H ;
HENZE, G .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 661 (01) :109-118
[6]   Interaction of anticancer drug methotrexate with nucleic acids analyzed by multi-spectroscopic method [J].
Cai, Changqun ;
Chen, Xiaoming ;
Gong, Hang .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2009, 72 (01) :46-49
[7]   Development and validation of a rapid 96-well format based liquid-liquid extraction and liquid chromatography-tandem mass spectrometry analysis method for ondansetron in human plasma [J].
Dotsikas, Yannis ;
Kousoulos, Constantinos ;
Tsatsou, Georgia ;
Loukas, Yannis L. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 836 (1-2) :79-82
[8]  
Emara S, 1997, BIOMED CHROMATOGR, V11, P42, DOI 10.1002/(SICI)1099-0801(199701)11:1<42::AID-BMC621>3.0.CO
[9]  
2-F
[10]  
Emara S, 1998, BIOMED CHROMATOGR, V12, P338, DOI 10.1002/(SICI)1099-0801(199811/12)12:6<338::AID-BMC759>3.0.CO