Detachable balloon-based endovascular fistula occlusion is a widely accepted treatment for traumatic carotid cavernous fistulas (CCF). However, more recently coils have been used to obliterate the lesion, especially in case detachable balloon is not available. We failed balloon-assisted coil embolization for CCF because of large fistulas and herniation of coil loops into the parent artery. The authors describe our experiences of balloon-expandable graft-stents to treat CCF, and place emphasis on arterial wall reconstruction. Three traumatic CCF patients were treated using a graft-stent with/without coils, and underwent angiographic follow-up to evaluate the patency of the internal carotid artery (ICA). In all cases, symptoms related to CCF regressed after stent deployment and did not recur during follow-up. Follow-up angiography revealed good patency of the ICA in all patients. Graft-stents should be considered as an alternative means of treating CCF and preserving the parent artery by arterial wall reconstruction especially in patients with a fistula that cannot be successfully occluded with detachable balloons or coils.
引用
收藏
页码:572 / 576
页数:5
相关论文
共 16 条
[1]  
Archondakis E, 2007, AM J NEURORADIOL, V28, P342
[2]   Polytetrafluoroethylene-covered stent and coronary artery aneurysms [J].
Briguori, C ;
Sarais, C ;
Sivieri, G ;
Takagi, T ;
Di Mario, C ;
Colombo, A .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (03) :326-330
[3]  
Carter B S, 2000, Clin Neurosurg, V46, P351
[4]   DETACHABLE BALLOON AND CALIBRATED-LEAK BALLOON TECHNIQUES IN TREATMENT OF CEREBRAL VASCULAR-LESIONS [J].
DEBRUN, G ;
LACOUR, P ;
CARON, JP ;
HURTH, M ;
COMOY, J ;
KERAVEL, Y .
JOURNAL OF NEUROSURGERY, 1978, 49 (05) :635-649
[5]   Coronary stent grafts covered by a polytetrafluoroethylene membrane [J].
Elsner, M ;
Auch-Schwelk, W ;
Britten, M ;
Walter, DH ;
Schächinger, V ;
Zeiher, AM .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (03) :335-+
[6]   Treatment of extracranial and intracranial aneurysms and arteriovenous fistulae using stent grafts [J].
Felber, S ;
Henkes, H ;
Weber, W ;
Miloslavski, E ;
Brew, S ;
Kühne, D .
NEUROSURGERY, 2004, 55 (03) :631-638
[7]   Treatment of carotid cavernous fistulas using covered stents: Midterm results in seven patients [J].
Gomez, F. ;
Escobar, W. ;
Gomez, A. M. ;
Gomez, J. F. ;
Anaya, C. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (09) :1762-1768
[8]   Transvenous treatment of carotid cavernous and dural arteriovenous fistulae: Results for 31 patients and review of the literature [J].
Klisch, J ;
Huppertz, HJ ;
Spetzger, U ;
Hetzel, A ;
Seeger, W ;
Schumacher, M .
NEUROSURGERY, 2003, 53 (04) :836-856
[9]   THE BENIGN COURSE OF CAVERNOUS CAROTID-ARTERY ANEURYSMS [J].
KUPERSMITH, MJ ;
HURST, R ;
BERENSTEIN, A ;
IN, SC ;
JAFAR, J ;
RANSOHOFF, J .
JOURNAL OF NEUROSURGERY, 1992, 77 (05) :690-693
[10]  
Lee TH, 2005, AM J NEURORADIOL, V26, P166