Memantine Potentiometric Membrane Sensor for Memantine Pharmaceutical Analysis; Computational Investigation

被引:0
|
作者
Ganjali, M. R. [1 ,2 ]
Aboufazeli, F. [1 ]
Riahi, S. [1 ,3 ]
Dinarvand, R. [4 ]
Norouzi, P. [1 ,2 ]
Ghasemi, M. H. [5 ]
Kiani-Anbuhi, R. [5 ]
Meftah, S. [5 ]
机构
[1] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[2] Med Sci Univ Tehran, Endocrinol & Metab Res Ctr, Tehran, Iran
[3] Univ Tehran, Fac Engn, Inst Petr Engn, Tehran, Iran
[4] Med Sci Univ Tehran, Med Nanotechnol Res Ctr, Tehran, Iran
[5] ACECR Tehran Branch, Appl Chem Res Grp, Tehran, Iran
来源
关键词
Potentiometric sensor; PVC membrane; Memantine; Computational Chemistry; Chemometrics; Density functional based tight binding (DFTB); LANTHANIDE RECOGNITION; HYDROCHLORIDE ANALYSIS; USEFUL DEVICE; FORMULATION; MICROSENSOR; ION; SELECTIVITY; PREDICTION; HYDRAZONE; ELECTRODE;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Memantine (MEM) is one of the first novel class medications for treatment of Alzheimer's disease. In this study a potentiometric liquid membrane sensor is used for simple and fast determination of Memantine in pharmaceutical formulation and urine. Computational studies were done electronically and geometrically on Memantine and tetraphenylborate before and after complex formation. These studies demonstrated tetraphenylbarate fits better with memantine than potassium tetrakis. Thus, for the membrane preparation Memantine-tetraphenylborate complexes were employed as electroactive materials in the membrane. The wide linear range (10(-5)-10(-2) mol L-1), low detection limit (9.0x10(-6) mol L-1), and fast response time (similar to 25s) are characterizations of the proposed sensors. Validation of the method shows suitability of the sensors for application in quality control analysis of Memantine in pharmaceutical formulation and urine.
引用
收藏
页码:1138 / 1152
页数:15
相关论文
共 50 条
  • [1] Potentiometric Membrane Sensors for the Selective Determination of Memantine Hydrochloride in Pharmaceutical Preparations
    El Nashar, Rasha M.
    El-Tantawy, Aliaa S. M.
    Hassan, Saad S. M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10802 - 10817
  • [2] Verapamil Potentiometric Membrane Sensor for Verapamil Pharmaceutical Analysis. Computational Investigation
    Faridbod, F.
    Ganjali, M. R.
    Safaraliee, L.
    Riahi, S.
    Hosseini, M.
    Norouzi, P.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (10): : 1419 - 1435
  • [3] Promethazine Potentiometric Membrane Sensor for Promethazine Hydrochloride Pharmaceutical Analysis; Computational Study
    Ganjali, Mohammad Reza
    Vesimohammadi, Bahareh
    Riahi, Siavash
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (05): : 740 - 754
  • [4] Quantitative Analysis of Pseudoephedrine in Formulation by Potentiometric Membrane Sensor; Computational Investigation
    Ganjali, Mohammad Reza
    Alipour, Aidin
    Riahi, Siavash
    Larijani, Bagher
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (09): : 1262 - 1276
  • [5] Potentiometric Membrane Sensors for Determination of Memantine Hydrochloride and Pramipexole Dihydrochloride Monohydrate
    Merey, Hanan A.
    Helmy, Marwa I.
    Tawakkol, Shereen M.
    Toubar, Safaa S.
    Risk, Mohamed S.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2012, 30 (01) : 31 - 43
  • [6] A biomimetic potentiometric sensor based on molecularly imprinted polymer for the determination of memantine in tablets
    Arvand, Majid
    Samie, Hedyeh Asadi
    DRUG TESTING AND ANALYSIS, 2013, 5 (06) : 461 - 467
  • [7] Quantitative Analysis of Prazosin Hydrochloride in Pharmaceutical Formulation by Prazosin Potentiometric Sensor Based on Computational Investigation
    Faridbod, Farnoush
    Ganjali, Mohammad Reza
    Larijani, Bagher
    Nasli-Esfahani, Ensieh
    Riahi, Siavash
    Norouzi, Parviz
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (05): : 653 - 667
  • [8] Preclinical Investigation of the Functional Effects of Memantine and Memantine Combined with Galantamine or Donepezil
    Diana S Woodruff-Pak
    Michael J Tobia
    Xilu Jiao
    Kevin D Beck
    Richard J Servatius
    Neuropsychopharmacology, 2007, 32 : 1284 - 1294
  • [9] Using dextromethorphan potentiometric membrane sensor in analysis of dextromethorphan hydrobromide in pharmaceutical formulation and urine; Computational study
    M. R. Ganjali
    B. Larijani
    H. Shams
    S. Riahi
    F. Faridbod
    P. Norouzi
    Journal of Analytical Chemistry, 2010, 65 : 1052 - 1060
  • [10] Using dextromethorphan potentiometric membrane sensor in analysis of dextromethorphan hydrobromide in pharmaceutical formulation and urine; Computational study
    Ganjali, M. R.
    Larijani, B.
    Shams, H.
    Riahi, S.
    Faridbod, F.
    Norouzi, P.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 65 (10) : 1052 - 1060